The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plasticgreenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of 15~20 ℃. Coolingpipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling rootzone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainlesssteel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed atflowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate comparedwith a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. Thetemperatures of root spot in root zone cooling was maintained at 18.0 ~ 23.0 ℃ and that of crown spot in crown cooling was maintained at 19~24 ℃. Also,the temperatures of root spot in crown plus root zone cooling bed was maintained at 17.0 ~ 22.0 ℃ and that of crown spot was maintained at 19~25 ℃.
Abstract
The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plasticgreenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of 15~20 ℃. Coolingpipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling rootzone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainlesssteel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed atflowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate comparedwith a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. Thetemperatures of root spot in root zone cooling was maintained at 18.0 ~ 23.0 ℃ and that of crown spot in crown cooling was maintained at 19~24 ℃. Also,the temperatures of root spot in crown plus root zone cooling bed was maintained at 17.0 ~ 22.0 ℃ and that of crown spot was maintained at 19~25 ℃.
참고문헌 (11)
- 전하준, "딸기의 뿌리및 지상부 생육에 미치는 근부온도의 영향", 시설원예‧식물공장, 17(1), pp.14~19 (2008), 한국생물환경조절학회
- 김기덕, "곤달비 여름재배 시 냉각방법과 냉수호스베드재배가 생육 및 미기상에 미치는 영향", 시설원예‧식물공장, 20(2), pp.116~122 (2011), 한국생물환경조절학회
- 김기동, "증발 냉각방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발", 시설원예‧식물공장, 19(4), pp.184~188 (2010), 한국생물환경조절학회
- 김기동, "다선식 가온방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발", 시설원예‧식물공장, 19(4), pp.189~194 (2010), 한국생물환경조절학회
- Kim, T. Y., "Effects of Energy Saving on Partial Heating for Pot Flower Bench Cultivation", Proceedings of the 2002 Annual Conference of the Korean Society for Bio-Environment Control Conference, pp.44~47 (2002)
- 이종남, "사계성 딸기 ‘강하’ 육성", 원예과학기술지, 28(3), pp.515~518 (2010), 한국원예학회
- 이권재, "공기열원 히트펌프의 난방 성능특성에 관한 실험적 연구", 설비공학 논문집, 23(6), pp.400~405 (2011), 대한설비공학회
- Nam, S. W., "Estimation of Soil Cooling Load in the Root Zone of Greenhouses", Journal of Bio-Environment Control, 11(4), pp.151~156 (2002)
- 남상운, "포그분사 및 공기유동에 의한 온실재배 토마토의 엽온 변화", 시설원예‧식물공장, 23(1), pp.11~18 (2014), (사) 한국생물환경조절학회
- 박재완, "저온기 딸기 고설 수경재배시 온실기온에 따른 배지내 온도강하 모델 개발", 시설원예‧식물공장, 19(3), pp.123~129 (2010), 한국생물환경조절학회
- Ryou, Y. S., "Heating and Cooling Effect of Portected Horticulture by Geothermal Heat Pump System with Horizontal Heat Exchanger", Proceedings of the 2008 spring annual conference of The Korean society for New and Renewable Energy, pp.630~633 (2008)