초록

Heat stress in broiler houses during the summer can lead to reduced feed intake and feed efficiency, ultimately resulting in decreased productivity. To mitigate heat stress, cooling pads utilizing the evaporative cooling effect have been introduced in commercial broiler houses. In this study, the performance of cooling pads in an actual broiler house was evaluated, and a wind tunnel equipment was designed to precisely analyze their performance. The results revealed that in the broiler house with long cooling pads, the uneven distribution of water led to a decrease in cooling efficiency. Specifically, cooling efficiency was 81% when the cooling pads were wet enough but decreased to 49.6% as the water supply to the cooling pads was not proper. Furthermore, wind tunnel experiments showed that as the airflow speed increased from 0.64 mㆍs-1 to 1.86 mㆍs-1, the temperature reduction decreased from 8.3 °C to 6.6 °C. However, the mass transfer coefficient and heat transfer coefficient increased by 0.0019 mㆍh⁻¹ and 37.32 Wㆍm-²ㆍK⁻¹, respectively, indicating more active evaporation and greater heat removal due to higher airflow speed. Additionally, as relative humidity increased, the temperature reduction significantly decreased. When water was unevenly distributed across the cooling pad, the temperature reduction and cooling efficiency in areas without water were significantly reduced. These findings highlight the importance of maintaining uniform water distribution over the cooling pads to ensure desired cooling effects.

Abstract

Heat stress in broiler houses during the summer can lead to reduced feed intake and feed efficiency, ultimately resulting in decreased productivity. To mitigate heat stress, cooling pads utilizing the evaporative cooling effect have been introduced in commercial broiler houses. In this study, the performance of cooling pads in an actual broiler house was evaluated, and a wind tunnel equipment was designed to precisely analyze their performance. The results revealed that in the broiler house with long cooling pads, the uneven distribution of water led to a decrease in cooling efficiency. Specifically, cooling efficiency was 81% when the cooling pads were wet enough but decreased to 49.6% as the water supply to the cooling pads was not proper. Furthermore, wind tunnel experiments showed that as the airflow speed increased from 0.64 mㆍs-1 to 1.86 mㆍs-1, the temperature reduction decreased from 8.3 °C to 6.6 °C. However, the mass transfer coefficient and heat transfer coefficient increased by 0.0019 mㆍh⁻¹ and 37.32 Wㆍm-²ㆍK⁻¹, respectively, indicating more active evaporation and greater heat removal due to higher airflow speed. Additionally, as relative humidity increased, the temperature reduction significantly decreased. When water was unevenly distributed across the cooling pad, the temperature reduction and cooling efficiency in areas without water were significantly reduced. These findings highlight the importance of maintaining uniform water distribution over the cooling pads to ensure desired cooling effects.

참고문헌 (20)

  1. Alodan, M. A., "Design and evaluation of galvanized metal sheets as evaporative cooling pads", J. King Saud Univ, 18, pp.9~18 (2005)
  2. "ASHRAE Standard ANSI", ASHRAE 133-2001, Method of testing direct evaporative air coolers, 2001, pp.24~
  3. Aziz, R. A., "Comparison on cooling efficiency of cooling pad materials for evaporative cooling system", Journal of Modern Manufacturing Systems and Technology, 1, pp.61~68 (2018)
  4. Technical background research on evaporative air conditioners and feasibility of rating their water consumption, "Bruno, F.", University of South Australia, ~ (2009)
  5. Dağtekin, M., "Long axis heat distribution in a tunnel-ventilated broiler house equipped with an evaporative pad cooling system", Animal Production Science, 49(12), pp.1125~1131 (2009)
  6. Dağtekin, M., "Performance characteristics of a pad evaporative cooling system in a broiler house in a Mediterranean climate", Biosystems Engineering, 103, pp.100~104 (2009)
  7. Dağtekin, M., "The effects of air velocity on the performance of pad evaporative cooling systems", African Journal of Agricultural Research, 6(7), pp.1813~1822 (2011)
  8. Jain, J. K., "Experimental performance of new evaporative cooling pad materials", Sustainable Cities and Society, 1(4), pp.252~256 (2011)
  9. Kittas, C., "Temperature gradients in a partially shaded large greenhouse equipped with evaporative cooling pads", Biosystems Engineering, 85(1), pp.87~94 (2003)
  10. Laknizi, A., "Performance characterization of a direct evaporative cooling pad based on pottery material", International Journal of Sustainable Engineering, 14(1), pp.46~56 (2019)
  11. Liao, C. M., "Wind tunnel modeling the system performance of alternative evaporative cooling pads in Taiwan region", Building and Environment, 37, pp.177~187 (2002)
  12. Malli, A., "Investigating the performance of cellulosic evaporative cooling pads", Energy Conversion and Management, 52(7), pp.2598~2603 (2011)
  13. Naveenprabhu, V., "Performance enhancement studies on evaporative cooling using volumetric heat and mass transfer coefficients", Numerical Heat Transfer, pp.1~20 (2020)
  14. Rong, L., "Dynamic performance of an evaporative cooling pad investigated in a wind tunnel for application in hot and arid climate", Biosystems Engineering, 156, pp.173~182 (2017)
  15. Simmons, J., "Evaporative cooling performance resulting from changes in water temperature", Applied Engineering in Agriculture, 12(4), pp.497~500 (1996)
  16. Song, D., "Effects of heat stress on broiler meat quality", World’s Poultry Science Journal, 71(4), pp.701~709 (2015)
  17. Teeter, R. G., "Broiler management during acute stress", Animal Feed Science and Technology, 58, pp.127~142 (1996)
  18. Tejero-González, A., "Optimal operation of evaporative cooling pads : a review", Renewable and Sustainable Energy Reviews, 151 (2021)
  19. Wu, J. M., "Theoretical analysis on heat and mass transfer in a direct evaporative cooler", Applied Thermal Engineering, 29(5-6), pp.980~984 (2009)
  20. Xu, J., "Experimental performance of evaporative cooling pad systems in greenhouses in humid subtropical climates", Applied Energy, 138, pp.291~301 (2015)

관련 논문AI추천