본문 바로가기
KERD
논문

강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석

Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류농학

초록

In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption,occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

Abstract

In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption,occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

참고문헌 (13)

  1. Abramovich, G. N., "The Theory of Turbulent Jets" (1963), MIT Press
  2. Berchmans, D., "Validity of the Archimedes number in ventilating commercial livestock buildings", Journal of Agricultural Engineering Research, 56(3), pp.239~251 (1993)
  3. Fluent, "The manual of computational fluid dynamics(CFD), Version 6.3" (2011), Fluent, Inc
  4. 홍세운, "BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석", 한국농공학회논문집, 50(1), pp.39~47 (2008), 한국농공학회
  5. Koestel, A., "Paths of horizontally projected heated and chilled air jets", Transactions of the ASHAE, 61, pp.213~232 (1955)
  6. 권경석, "전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계", 한국농공학회논문집, 52(3), pp.19~29 (2010), 한국농공학회
  7. Lee, I. B., "Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house", Japan Agricultural Research Quarterly, 41(1), pp.53~64 (2007)
  8. Leonard, J. J., "Archimedes number criteria for the control of cold ventilation air jets", Canadian Agricultural Engineering, 28(2), pp.117~123 (1986)
  9. Park, Y. W., "Analysis of heating energy in a naturally ventilated broiler house", The Society of Air-Conditioning and Refrigerating Engineers of Korea, 58 (2004)
  10. Randall, J. M., "Stability criteria for airflow patterns in livestock buildings", Journal of Agricultural Engineering Research, 24(4), pp.361~374 (1979)
  11. "Statistics Korea"[URL]
  12. Zhang, G., "Modeling jet drop distances for control of a nonisothermal flapadjusted ventilation jet", American Society of Agricultural Engineers, 39(4), pp.1421~1431 (1996)
  13. Zhang, G., "Jet drop models for control of non-isothermal free jets in a side-wall multi-inlet ventilation system", American Society of Agricultural Engineers, 32(4), pp.1121~1126 (1999)

이 간행물의 다른 논문 (16건)