Prediction of Refractive Error in Combined Vitrectomy and Cataract Surgery With One-Piece Acrylic Intraocular Lens
1
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Purpose: To compare the predicted and actual refractive errors of hydrophilic, one-piece, C-flex®570C (C-flex) intraocular lens (IOL) implantation in simultaneous vitrectomy and lens extraction in various conditions. Methods: One hundred fifty-nine eyes of patients who had lens extraction between March 2004 and September 2005 were enrolled in a retrospective study. Group 1 had lens extraction and IOL implantation, and Group 2 had lens extraction and IOL implantation with vitrectomy. IOL calculation was done with axial length and keratometry measurements. The actual and predicted refractive errors were compared at 1 and 6 months postoperatively. The factors influencing the postoperative refractive outcomes were analyzed. Results: The mean refractive predictive error (i.e., the actual minus predicted spherical equivalent) was +0.19±0.39 D (Diopter) and -0.26±0.45 D at 1 and 6 months postoperatively (all: p<0.001) in group 1, and -0.22±0.39 D and -0.06±0.62 D at 1 and 6 months postoperatively (p=0.013, p=0.399 respectively). In group 2, all surgical factors related to refractive errors were not statistically significant (all: p>0.05). Conclusions: Refractive errors in combined surgery showed myopic shift of -0.50 D and -0.32 D at 1 and 6 months postoperatively compared with C-flex IOL implantation alone. With the hyperopic tendency of IOL and myopic tendency of vitrectomy, the combined surgery made postoperative refractive errors near emmetropia.
Abstract
Purpose: To compare the predicted and actual refractive errors of hydrophilic, one-piece, C-flex®570C (C-flex) intraocular lens (IOL) implantation in simultaneous vitrectomy and lens extraction in various conditions. Methods: One hundred fifty-nine eyes of patients who had lens extraction between March 2004 and September 2005 were enrolled in a retrospective study. Group 1 had lens extraction and IOL implantation, and Group 2 had lens extraction and IOL implantation with vitrectomy. IOL calculation was done with axial length and keratometry measurements. The actual and predicted refractive errors were compared at 1 and 6 months postoperatively. The factors influencing the postoperative refractive outcomes were analyzed. Results: The mean refractive predictive error (i.e., the actual minus predicted spherical equivalent) was +0.19±0.39 D (Diopter) and -0.26±0.45 D at 1 and 6 months postoperatively (all: p<0.001) in group 1, and -0.22±0.39 D and -0.06±0.62 D at 1 and 6 months postoperatively (p=0.013, p=0.399 respectively). In group 2, all surgical factors related to refractive errors were not statistically significant (all: p>0.05). Conclusions: Refractive errors in combined surgery showed myopic shift of -0.50 D and -0.32 D at 1 and 6 months postoperatively compared with C-flex IOL implantation alone. With the hyperopic tendency of IOL and myopic tendency of vitrectomy, the combined surgery made postoperative refractive errors near emmetropia.
참고문헌 (32)
- Demetriades AM, "Combined phacoemulsification, intraocular lens implantation and vitrectomy for eyes with coexisting cataract and vitreoretinal pathology", Am J Ophthalmol, 135, pp.291~6 (2003)
- Senn P, "Combined pars plana vitrectomy, phacoemulsification and intraocular lens implantation in the capsular bag: a comparison to vitrectomy and subsequent cataract surgery as a two-step procedure", Ophthalmic Surg Laser, 26, pp.420~8 (1996)
- Honjo M, "Surgical results of pars plana vitrectomy combined with phacoemulsification and intraocular lens implantation for complications of proliferative diabetic retinopathy", Ophthalmic Surg Lasers, 29, pp.99~105 (1998)
- Scharwey K, "Combined clear corneal phacoemulsification, vitreoretinal surgery, and intraocular lens implantation", J Cataract Refract Surg, 25, pp.693~8 (1999)
- Koenig SB, "Combined phacoemulsification and pars plana vitrectomy", Arch Ophthalmol, 108, pp.362~4 (1990)
- Nishi Y, "Influence of 360-degree enhanced optic edge design of a hydrophilic acrylic intraocular lens in posterior capsule opacification", J Cataract Refract Surg, 33, pp.227~31 (2007)
- Vyas AV, "Three-hundred-sixty degree barrier effect of a square-edged and an enhanced-edge intraocular lens on centripetal lens epithelial cell migration; Two-year results", J Cataract Refract Surg, 33, pp.81~7 (2007)
- Werner L, "Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge", J Cataract Refract Surg, 30, pp.2403~9 (2004)
- Kleinmann G, "Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses", Br J Ophthalmol, 91, pp.1070~2 (2007)
- Taskapili M, "Transscleral fixation of a single-piece hydrophilic foldable acrylic intraocular lens", Can J Ophthalmol, 42, pp.256~61 (2007)
- Oner FH, "Interaction of intraocular lenses with various concentrations of silicone oil: an experimental study", Ophthalmologica, 217, pp.124~8 (2003)
- Steinert RF, "Astigmatism after small incision cataract surgery: a prospective, ramdomized, multicenter comparison of 4-and 6.5-mm incisions", Ophthalmology, 98, pp.417~24 (1991)
- Levy JH, "Astigmatism changes after cataract surgery with 5.1mm and 3.5mm sutureless incision", J Cataract Refract Surg, 20, pp.630~3 (1994)
- Menapace R, "Exchange of IOGEL hydrogel one piece foldable intraocular lenses for bag-fixated J-loop poly (methylmethacrylate) intraocular lens", J Cataract Refract Surg, 19, pp.425~30 (1993)
- Olsen T, "Sources of error in intraocular lens power calculation", J Cataract Refract Surg, 18, pp.125~9 (1992)
- McEwan JR, "Effect of keratometer and axial length measurement errors in primary implant power calculations", J Cataract Refract Surg, 16, pp.61~70 (1990)
- Hoffer KJ, "Modern IOL power calculations: Avoiding error and planning for special circumstances", Focal Point, 17, pp.12~ (1999)
- Holladay JT, "Standardising constants for ultrasonic biometry, keratometry and intraocular lens power calculations", J Cataract Refract Surg, 23, pp.1356~70 (1997)
- Assia EI, "Loop memory of posterior chamber intraocular lenses of various size, and loop materials", J Cataract Refract Surg, 18, pp.541~6 (1992)
- Chang JH, "Clinical evaluation of AMO Phacoflex SI-30NB in the aspect of A-constant", J Korean Ophthalmol Soc, 40, pp.987~94 (1999)
- 김용은, "인공수정체 종류에 따른 예측굴절력과 실제굴절력의 차이", 대한안과학회지, 44(5), pp.1059~1065 (2003), 대한안과학회
- Na SJ, "Clinical Results of Centerflex® intraocular ocular lenses and Acrysof® intraocular ocular lenses in bilateral cataracts", J Korean Ophthalmol Soc, 45, pp.1066~74 (2004)
- Kim JY, "The clinical results of hydrophilic acrylic lens", J Korean Ophthalmol Soc, 42, pp.1562~70 (2001)
- 김준현, "유리체절제술과 병행된 수정체 초음파유화술시 공막터널절개와 투명각막절개의 비교", 대한안과학회지, 47(10), pp.1583~1588 (2006), 대한안과학회
- Danjo Y, "Catatact surgery for avitreous eyes-postoperative refractive prediction", folia Ophthalmologica Japonica, 44, pp.1243~7 (1993)
- Suzuki Y, "Postoperative refractive error after simultaneous vitrectomy and cataract surgery", Ophthalmic Surg Lasers, 31, pp.271~5 (2000)
- Shioya M, "Change in postoperative refractive error when vitrectomy is added to intraocular lens implantation", J Cataract Refract Surg, 23, pp.1217~20 (1997)
- Nishigaki S, "The postoperative change of depth of anterior chamber, refraction and anterior capsulorhexis size after intraocular lens implantation", Nippon Ganka Zasshi, 100, pp.156~8 (1996)
- 김대홍, "유리체절제술에 동반된 인공수정체 삽입술에서 술 후 굴절값의 비교", 대한안과학회지, 43(9), pp.1644~1648 (2002), 대한안과학회
- 최영주, "황반원공 환자에서 유리체절제술 후 굴절값의 변화", 대한안과학회지, 44(8), pp.1813~1817 (2003), 대한안과학회
- Jeoung JW, "Factors influencing refractive outcomes after combined phacoemulsification and pars plana vitrectomy Results of a prospective study", J Cataract Refract Surg, 33, pp.108~14 (2007)
- Kovács I, "Intraocular lens power calculation for combined cataract surgery, vitrectomy and peeling of epiretinal membranes for macular oedema", Acta Ophthalmol Scand, 85, pp.88~91 (2007)
