Purpose: To investigate the outcomes of scleral buckling surgery performed under a slit-lamp illumination system(Visulux) with a contact wide-angle viewing lens (Mini Quad) in patients with rhegmatogenous retinal detachment(RRD) and to compare these outcomes with those of surgery performed under an indirect ophthalmoscope. Methods: By retrospective review of electronic medical records, patients with RRD who had undergone scleralbuckling surgery were identified. Scleral buckling surgeries were performed with two illumination instruments,a slit-lamp (SL group) and an indirect ophthalmoscope (IO group). Subretinal fluid drainage, cryopexy, andintravitreal gas injection were performed optionally. At 6 months after surgery, anatomical and functional outcomeswere evaluated and compared between the two groups. Operation time was also compared betweenthe two groups. Results: Of the 45 total patients (45 eyes), 28 were included in the SL group, and 17 were included in the IOgroup. In the SL and IO groups, the primary anatomical success rate was 89.3% and 88.2%, respectively (p =0.92). The logarithm of the minimal angle of resolution change, which reflects improvement in best-correctedvisual acuity after surgery, was -0.19 ± 0.38 in the SL group and -0.21 ± 0.63 in the IO group; this differencewas not statistically significant (p = 0.91). The mean operation time was significantly shorter in the SL group(78.9 ± 11.8 minutes) than in the IO group (100.0 ± 13.9 minutes, p < 0.001), especially for patients who underwentadditional procedures such as subretinal fluid drainage and cryopexy (81.4 ± 12.9 and 103.5 ± 12.3 minutes,respectively, p < 0.001). Conclusions: Scleral buckling surgery performed under a slit-lamp illumination system yielded a similar anatomicalsuccess rate and similar functional improvement in RRD compared with surgery performed under anindirect ophthalmoscope. The slit-lamp system could save time, especially in bullous RRD, which requires additionalsubretinal fluid drainage.

Abstract

Purpose: To investigate the outcomes of scleral buckling surgery performed under a slit-lamp illumination system(Visulux) with a contact wide-angle viewing lens (Mini Quad) in patients with rhegmatogenous retinal detachment(RRD) and to compare these outcomes with those of surgery performed under an indirect ophthalmoscope. Methods: By retrospective review of electronic medical records, patients with RRD who had undergone scleralbuckling surgery were identified. Scleral buckling surgeries were performed with two illumination instruments,a slit-lamp (SL group) and an indirect ophthalmoscope (IO group). Subretinal fluid drainage, cryopexy, andintravitreal gas injection were performed optionally. At 6 months after surgery, anatomical and functional outcomeswere evaluated and compared between the two groups. Operation time was also compared betweenthe two groups. Results: Of the 45 total patients (45 eyes), 28 were included in the SL group, and 17 were included in the IOgroup. In the SL and IO groups, the primary anatomical success rate was 89.3% and 88.2%, respectively (p =0.92). The logarithm of the minimal angle of resolution change, which reflects improvement in best-correctedvisual acuity after surgery, was -0.19 ± 0.38 in the SL group and -0.21 ± 0.63 in the IO group; this differencewas not statistically significant (p = 0.91). The mean operation time was significantly shorter in the SL group(78.9 ± 11.8 minutes) than in the IO group (100.0 ± 13.9 minutes, p < 0.001), especially for patients who underwentadditional procedures such as subretinal fluid drainage and cryopexy (81.4 ± 12.9 and 103.5 ± 12.3 minutes,respectively, p < 0.001). Conclusions: Scleral buckling surgery performed under a slit-lamp illumination system yielded a similar anatomicalsuccess rate and similar functional improvement in RRD compared with surgery performed under anindirect ophthalmoscope. The slit-lamp system could save time, especially in bullous RRD, which requires additionalsubretinal fluid drainage.

참고문헌 (23)

  1. Escoffery RF, "Vitrectomy without scleral buckling for primary rhegmatogenous retinal detachment", Am J Ophthalmol, 99, pp.275~281 (1985)[DOI]
  2. Ho CL, "Selection of scleral buckling for primary retinal detachment", Ophthalmologica, 216, pp.33~39 (2002)[DOI]
  3. Schwartz SG, "Primary retinal detachment: scleral buckle or pars plana vitrectomy?", Curr Opin Ophthalmol, 17, pp.245~250 (2006)[DOI]
  4. Schepens CL, "The scleral buckling procedures. I. Surgical techniques and management", AMA Arch Ophthalmol, 58, pp.797~811 (1957)[DOI]
  5. Aras C, "Scleral buckling with a non-contact wide-angle viewing system", Ophthalmologica, 227, pp.107~110 (2012)[DOI]
  6. Narayanan R, "Scleral buckling with wide-angled endoillumination as a surgical educational tool", Retina, 36, pp.830~833 (2016)[DOI]
  7. Gogia V, "Endoilluminator-assisted scleral buckling: our results", Indian J Ophthalmol, 62, pp.893~894 (2014)[DOI]
  8. Hu Y, "Outcomes of scleral buckling using chandelier endoillumination", Acta Ophthalmol, 95, pp.591~594 (2017)[DOI]
  9. Seider MI, "Scleral buckling with chandelier illumination", J Ophthalmic Vis Res, 11, pp.304~309 (2016)[DOI]
  10. Zhang Z, "The scleral buckling of primary rhegmatogenous retinal detachment under the surgical microscope", Ophthalmic Surg Lasers Imaging, 42, pp.96~101 (2011)
  11. Ohji M, "Vitreoretinal surgery with slit-lamp illumination combined with a wide-angle-viewing contact lens", Am J Ophthalmol, 137, pp.955~956 (2004)[DOI]
  12. McPherson SD Jr., "A modified Zeiss operating slit-lamp microscope", Trans Am Ophthalmol Soc, 66, pp.419~420 (1968)
  13. Bonnet M, "Biomicroscopy of the fundus in retinal detachment surgery", J Fr Ophtalmol, 2, pp.209~216 (1979)
  14. The repair of rhegmatogenous retinal detachments, "American Academy of Ophthalmology", Ophthalmology, 103, pp.1313~1324 (1996)[DOI]
  15. Sharma A, "Management of primary rhegmatogenous retinal detachment with inferior breaks", Br J Ophthalmol, 88, pp.1372~1375 (2004)[DOI]
  16. Park SW, "Comparison of scleral buckling and vitrectomy using wide angle viewing system for rhegmatogenous retinal detachment in patients older than 35 years", BMC Ophthalmol, 15, pp.121~ (2015)[DOI]
  17. Setlur VJ, "Combined 23-gauge PPV and scleral buckle versus 23-gauge PPV alone for primary repair of pseudophakic rhegmatogenous retinal detachment", Ophthalmic Surg Lasers Imaging Retina, 46, pp.702~707 (2015)[DOI]
  18. Haug SJ, "Chandelier-assisted external subretinal fluid drainage in primary scleral buckling for treatment of rhegmatogenous retinal detachment", Retina, 36, pp.203~205 (2016)[DOI]
  19. Li XJ, "Comparison of scleral buckling using wide-angle viewing systems and indirect ophthalmoscope for rhegmatogenous retinal detachment", Int J Ophthalmol, 9, pp.1310~1314 (2016)
  20. Temkar S, "Endoillumination (chandelier) assisted scleral buckling for a complex case of retinal detachment", Indian J Ophthalmol, 64, pp.845~846 (2016)[DOI]
  21. Yan H, "Scleral buckling with a noncontact wide-angle viewing system in the management of rhegmatogenous retinal detachment", Eur J Ophthalmol, 27, pp.98~103 (2017)[DOI]
  22. Nawrocki J, "Optic Fibre Free Intravitreal Surgical System (OFFISS) in retinal detachment surgery", Ophthalmic Surg Lasers Imaging, 39, pp.466~470 (2008)[DOI]
  23. Pagot V, "Surgery of retinal detachment of patients with pseudophakia using the panfunduscope", J Fr Ophtalmol, 15, pp.587~591 (1992)

관련 논문AI추천

이 간행물의 다른 논문 (14건)