본문 바로가기
KERD
논문KCI 등재

Effects of Cyclotorsion Orientation and Magnitude in Eyes with Compound Myopic Astigmatism on the Compensation Capacity of WaveLight EX500 Photorefractive Keratectomy

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To investigate the clinical effects of different orientation and magnitude of cyclotorsion on the compensationcapacity of the WaveLight EX500 photorefractive keratectomy (PRK) platform. Methods: This retrospective study comprised 400 eyes of 200 patients who underwent bilateral simultaneousPRK due to compound myopic astigmatism. The subjects were separated according to the orientation of cyclotorsioninto incyclotorsion and excyclotorsion groups, and by the magnitude of cyclotorsion into group 1 (0.50to 2.50 degrees), group 2 (3.00 to 5.00 degrees), group 3 (5.50 to 7.50 degrees), and group 4 (8.00 to 9.50 degrees). Results: The mean magnitude of cyclotorsion was 3.50 ± 2.4 degrees (0.50 to 9.50 degrees) in the incyclotorsiongroup and 3.32 ± 2.3 degrees (0.50 to 9.50 degrees) in the excyclotorsion group (p = 0.617). The postoperativerefractive outcomes of the incyclotorsion and excyclotorsion groups were similar (p > 0.05 for all). Thepostoperative mean cylindrical refractive error was -0.32 ± 0.3 diopters (D, -1.25 to 0.00 D) in group 1, -0.47 ± 0.2D (-2.00 to 0.00 D) in group 2, -0.62 ± 0.2 D (-1.00 to -0.25 D) in group 3, and -0.91 ± 0.2 D (-1.50 to -0.50 D) ingroup 4 (p < 0.001). Preoperative cylindrical refractive error was positively correlated with magnitude of cyclotorsion(r = 0.125 and p = 0.013), which was also positively correlated with postoperative cylindrical refractiveerror (r = 0.600 and p < 0.001). Conclusions: Incyclotorsion and excyclotorsion can be equally compensable in the WaveLight EX500 PRKplatform for compound myopic astigmatism. A value of ≤2.50 degrees cyclotorsion magnitude was observedto be more compensable than higher degrees of cyclotorsion magnitude. Preoperative high astigmatism wasassociated with high cyclotorsion magnitude, which was also associated with a high degree of postoperativeastigmatism.

Abstract

Purpose: To investigate the clinical effects of different orientation and magnitude of cyclotorsion on the compensationcapacity of the WaveLight EX500 photorefractive keratectomy (PRK) platform. Methods: This retrospective study comprised 400 eyes of 200 patients who underwent bilateral simultaneousPRK due to compound myopic astigmatism. The subjects were separated according to the orientation of cyclotorsioninto incyclotorsion and excyclotorsion groups, and by the magnitude of cyclotorsion into group 1 (0.50to 2.50 degrees), group 2 (3.00 to 5.00 degrees), group 3 (5.50 to 7.50 degrees), and group 4 (8.00 to 9.50 degrees). Results: The mean magnitude of cyclotorsion was 3.50 ± 2.4 degrees (0.50 to 9.50 degrees) in the incyclotorsiongroup and 3.32 ± 2.3 degrees (0.50 to 9.50 degrees) in the excyclotorsion group (p = 0.617). The postoperativerefractive outcomes of the incyclotorsion and excyclotorsion groups were similar (p > 0.05 for all). Thepostoperative mean cylindrical refractive error was -0.32 ± 0.3 diopters (D, -1.25 to 0.00 D) in group 1, -0.47 ± 0.2D (-2.00 to 0.00 D) in group 2, -0.62 ± 0.2 D (-1.00 to -0.25 D) in group 3, and -0.91 ± 0.2 D (-1.50 to -0.50 D) ingroup 4 (p < 0.001). Preoperative cylindrical refractive error was positively correlated with magnitude of cyclotorsion(r = 0.125 and p = 0.013), which was also positively correlated with postoperative cylindrical refractiveerror (r = 0.600 and p < 0.001). Conclusions: Incyclotorsion and excyclotorsion can be equally compensable in the WaveLight EX500 PRKplatform for compound myopic astigmatism. A value of ≤2.50 degrees cyclotorsion magnitude was observedto be more compensable than higher degrees of cyclotorsion magnitude. Preoperative high astigmatism wasassociated with high cyclotorsion magnitude, which was also associated with a high degree of postoperativeastigmatism.

참고문헌 (20)

  1. Collewijn H, "Human ocular counterroll : assessment of static and dynamic properties from electromagnetic scleral coil recordings", Exp Brain Res, 59, pp.185~196 (1985)
  2. Tjon-Fo-Sang MJ, "Cyclotorsion : a possible cause of residual astigmatism in refractive surgery", J Cataract Refract Surg, 28, pp.599~602 (2002)
  3. Rocha GJ, "Study of torsional movements in refractive surgery", Arq Bras Oftalmol, 68, pp.769~772 (2005)
  4. Bicas HE, "Ocular motility : foundations", Arq Bras Oftalmol, 66, pp.687~700 (2003)
  5. Guirao A, "Effect of rotation and translation on the expected benefit of an ideal method to correct the eye’s higher-order aberrations", J Opt Soc Am A Opt Image Sci Vis, 18, pp.1003~1015 (2001)
  6. Tunnacliffe AH, "Optics", pp.93~ (1996), Association of British Dispensing Opticians
  7. Popp N, "Evaluation of 4corneal astigmatic marking methods", J Cataract Refract Surg, 38, pp.2094~2099 (2012)
  8. Swami AU, "Rotational malposition during laser in situ keratomileusis", Am J Ophthalmol, 133, pp.561~562 (2002)
  9. Zhao F, "Correlative factors’ analysis of postural-related ocular cyclotorsion with image-guided system", Jpn J Ophthalmol, 62, pp.237~242 (2018)
  10. Ganesh S, "Results of intraoperative manual cyclotorsion compensation for myopic astigmatism in patients undergoing small incision lenticule extraction(SMILE)", J Refract Surg, 33, pp.506~512 (2017)
  11. Kim H, "Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis", J Cataract Refract Surg, 34, pp.557~561 (2008)
  12. Hummel CD, "Cyclorotation during femtosecond laser-assisted cataract surgery measured using iris registration", J Cataract Refract Surg, 43, pp.952~955 (2017)
  13. Alipour F, "Factors influencing cyclotorsion during photorefractive keratectomy", J Refract Surg, 34, pp.106~112 (2018)
  14. Adib-Moghaddam S, "Factors associated with ocular cyclotorsion detected by high-speed dual-detection eye tracker during single-step transepithelial photorefractive keratectomy", J Refract Surg, 34, pp.736~744 (2018)
  15. Aslanides IM, "The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism", Cont Lens Anterior Eye, 34, pp.114~120 (2011)
  16. Chang J, "Cyclotorsion during laser in situ keratomileusis", J Cataract Refract Surg, 34, pp.1720~1726 (2008)
  17. Tomita M, "Supplementary effect of static cyclotorsion compensation with dynamic cyclotorsion compensation on the refractive and visual outcomes of laser in situ keratomileusis for myopic astigmatism", J Cataract Refract Surg, 39, pp.752~758 (2013)
  18. Prakash G, "Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis", Am J Ophthalmol, 149, pp.229~237 (2010)
  19. Fahd DC, "Static cyclotorsion measurements using the Schwind Amaris laser", Arq Bras Oftalmol, 77, pp.159~163 (2014)
  20. Ivarsen A, "Safety and complications of more than 1500 small-incision lenticule extraction procedures", Ophthalmology, 121, pp.822~828 (2014)

관련 논문AI추천

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism이훈, 김응권, 김태임, 최진영, David Sung Yong Kang, Jeihoon Lee연세대학교의과대학 · Yonsei Medical Journal2016 · 제57권 제6호Comparison of Corneal Wavefront-optimized and Wavefront-guided Alcohol-assisted Photorefractive Keratectomy Using Schwind Amaris 750S Laser for Myopia정소향, Jehyung Hwang, Min-Ji Kang대한안과학회 · Korean Journal of Ophthalmology2020 · 제34권 제3호Comparison of Outcomes after Wavefront-optimized and Topography-guided Transepithelial Photorefractive KeratectomySangkyung Choi, SooJin Kim, Sung-Ho Choi, Sungjin Na대한안과학회 · Korean Journal of Ophthalmology2024 · 제38권 제4호The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia김미금, 위원량, 이상목, 이진학, 이현주, Min Joung Lee대한안과학회 · Korean Journal of Ophthalmology2007 · 제21권 제3호Clinical Outcomes of Small Incision Lenticule Extraction in Myopia: Study of Vector Parameters and Corneal Aberrations곽지용, 김응권, 김태임, 서경률, 전익현대한안과학회 · Korean Journal of Ophthalmology2020 · 제34권 제1호Clinical Outcomes of an Optimized Prolate Ablation Procedure for Correcting Residual Refractive Errors Following Laser Surgery이훈, 김대연, 김응권, 김태임, 서경률, 정병훈, 최봉준대한안과학회 · Korean Journal of Ophthalmology2017 · 제31권 제1호

이 간행물의 다른 논문 (14건)