Purpose: To evaluate a customized, portable Farnsworth-Munsell 100 (FM 100) hue viewing booth for compliance with colour vision testing standards and to compare it with room illumination in subjects with normal colour vision (trichromats), subjects with acquired colour vision defects (secondary to diabetes mellitus), and subjects with congenital colour vision defects (dichromats). Methods: Discrete wavelengths of the tube in the customized booth were measured using a spectrometer using the normal incident method and were compared with the spectral distribution of sunlight. Forty-eight subjects were recruited for the study and were divided into 3 groups: Group 1, Normal Trichromats (30 eyes); Group 2, Congenital Colour Vision Defects (16 eyes); and Group 3, Diabetes Mellitus (20 eyes). The FM 100 hue test performance was compared using two illumination conditions, booth illumination and room illumination. Results: Total error scores of the classical method in Group 2 as mean±SD for room and booth illumination was 243.05±85.96 and 149.85±54.50 respectively (p=0.0001). Group 2 demonstrated lesser correlation (r=0.50, 0.55), lesser reliability (Cronbach’s alpha, 0.625, 0.662) and greater variability (Bland & Altman value, 10.5) in total error scores for the classical method and the moment of inertia method between the two illumination conditions when compared to the other two groups. Conclusions: The customized booth demonstrated illumination meeting CIE standards. The total error scores were overestimated by the classical and moment of inertia methods in all groups for room illumination compared with booth illumination, however overestimation was more significant in the diabetes group.

Abstract

Purpose: To evaluate a customized, portable Farnsworth-Munsell 100 (FM 100) hue viewing booth for compliance with colour vision testing standards and to compare it with room illumination in subjects with normal colour vision (trichromats), subjects with acquired colour vision defects (secondary to diabetes mellitus), and subjects with congenital colour vision defects (dichromats). Methods: Discrete wavelengths of the tube in the customized booth were measured using a spectrometer using the normal incident method and were compared with the spectral distribution of sunlight. Forty-eight subjects were recruited for the study and were divided into 3 groups: Group 1, Normal Trichromats (30 eyes); Group 2, Congenital Colour Vision Defects (16 eyes); and Group 3, Diabetes Mellitus (20 eyes). The FM 100 hue test performance was compared using two illumination conditions, booth illumination and room illumination. Results: Total error scores of the classical method in Group 2 as mean±SD for room and booth illumination was 243.05±85.96 and 149.85±54.50 respectively (p=0.0001). Group 2 demonstrated lesser correlation (r=0.50, 0.55), lesser reliability (Cronbach’s alpha, 0.625, 0.662) and greater variability (Bland & Altman value, 10.5) in total error scores for the classical method and the moment of inertia method between the two illumination conditions when compared to the other two groups. Conclusions: The customized booth demonstrated illumination meeting CIE standards. The total error scores were overestimated by the classical and moment of inertia methods in all groups for room illumination compared with booth illumination, however overestimation was more significant in the diabetes group.

참고문헌 (8)

  1. Smith VC, "Effect of hypoxia on FM 100- Hue test performance", Mod Probl Ophthalmol, 17, pp.248~256 (1976)
  2. Farnsworth D, "The Farnsworth-Munsell 100-hue test for the examination of color discrimination", pp.2~5 (1957), Munsell Color Company
  3. Johnson DD, "The True Daylight Illuminator (TDI): a less expensive source of illumination for color vision screening", J Am Optom Assoc, 63, pp.491~495 (1992)
  4. Lakowski R, "Theory and practice of colour vision testing: a review 2", Br J Ind Med, 26, pp.265~288 (1969)
  5. Validation of an inexpensive illuminant for aeromedical color vision screening: final report, "Milburn NJ", National Technical Information Service, 1~11 (1993)
  6. Birch J, "Diagnosis of defective colour vision. 2nd ed", pp.123~125 (2001), Butterworth-Heinemann
  7. Judd DB, "Spectral distribution of typical daylight as a function of correlated color temperature", J Opt Soc Am, 54, pp.1031~1036 (1964)
  8. Barton FB, "ETDRS Research Group. Classification of Farnsworth-Munsell 100-hue test results in the early treatment diabetic retinopathy study", Am J Ophthalmol, 138, pp.119~124 (2004)

관련 논문AI추천

이 간행물의 다른 논문 (12건)