Comparison of OVD and BSS for Maintaining the Anterior Chamber during IOL Implantation
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To compare surgical results between conventional intraocular lens (IOL) implantation using an ophthalmic viscosurgical device (OVD) and IOL implantation using a balanced salt solution (BSS) after irrigation/aspiration (I/A) of the lens cortex. Methods: A randomized prospective study was conducted on 62 patients who underwent cataract surgery. Following completion of conventional I/A of the lens cortex, we divided patients into two groups according to whether or not BSS was used. In group A (n = 31), the anterior chamber and the capsular bag were completely filled with an OVD before IOL implantation. On the other hand, in group B (n = 31), BSS was irrigated into the anterior chamber through a previous side port during IOL implantation. Surgical results were compared between the two groups. Results: In both groups, IOP peaked six hours after surgery. The occurrence of an IOP spike by postoperative day one was observed in six cases (6 / 31) in group A and in no cases (0 / 31) in group B, a difference that was statistically significant (p = 0.024). The values of endothelial cell density, central corneal thickness, anterior chamber inflammation, myopic shift, and posterior capsule opacification were not significantly different between the two groups. Conclusions: Compared with the use of OVD for IOL implantation, use of BSS during IOL implantation resulted in reductions in postoperative IOP spike and OVD removal time.
Abstract
Purpose: To compare surgical results between conventional intraocular lens (IOL) implantation using an ophthalmic viscosurgical device (OVD) and IOL implantation using a balanced salt solution (BSS) after irrigation/aspiration (I/A) of the lens cortex. Methods: A randomized prospective study was conducted on 62 patients who underwent cataract surgery. Following completion of conventional I/A of the lens cortex, we divided patients into two groups according to whether or not BSS was used. In group A (n = 31), the anterior chamber and the capsular bag were completely filled with an OVD before IOL implantation. On the other hand, in group B (n = 31), BSS was irrigated into the anterior chamber through a previous side port during IOL implantation. Surgical results were compared between the two groups. Results: In both groups, IOP peaked six hours after surgery. The occurrence of an IOP spike by postoperative day one was observed in six cases (6 / 31) in group A and in no cases (0 / 31) in group B, a difference that was statistically significant (p = 0.024). The values of endothelial cell density, central corneal thickness, anterior chamber inflammation, myopic shift, and posterior capsule opacification were not significantly different between the two groups. Conclusions: Compared with the use of OVD for IOL implantation, use of BSS during IOL implantation resulted in reductions in postoperative IOP spike and OVD removal time.
참고문헌 (18)
- Tognetto D, "Survey of ophthalmic viscosurgical devices", Curr Opin Ophthalmol, 15, pp.29~32 (2004)
- Kim MS, "Clinical evaluation of domestic hyal 2000(R)as a viscoelastic substance in phacoemulsification with posterior chamver intraocular lens", J Korean Ophthalmol Soc, 39, pp.2064~2073 (1998)
- Park YK, "The changes of corneal endothelial morphology after phacoemulsification by using healon gv of viscoat", J Korean Ophthalmol Soc, 39, pp.1729~1734 (1998)
- Long-term corneal endothelial cell loss after cataract surgery, "Results of a randomized controlled trial.Oxford Cataract Treatment and Evaluation Team(OCTET)", Arch Ophthalmol, 104, pp.1170~1175 (1986)
- Ruiz RS, "Management of increased intraocular pressure after cataract extraction", Am J Ophthalmol, 103, pp.487~491 (1987)
- Bomer TG, "Intraocular pressure rise after phacoemulsification with posterior chamber lens implantation:effect of prophylactic medication,wound closure,and surgeon's experience", Br J Ophthalmol, 79, pp.809~813 (1995)
- Lehmann R, "Clinical comparison of Provisc and Healon in cataract surgery", J Cataract Refract Surg, 21, pp.543~547 (1995)
- Arshinoff SA, "Prospective,randomized trial comparing Micro Visc Plus and Healon GV in routine phacoemulsification", J Cataract Refract Surg, 24, pp.814~820 (1998)
- Berson FG, "Obstruction of aqueous outflow by sodium hyaluronate in enucleated human eyes", Am J Ophthalmol, 95, pp.668~672 (1983)
- Arshinoff S, "Postoperative intraocular pressure spikes", J Cataract Refract Surg, 30, pp.733~734 (2004)
- Kocak-Altintas AG, "Effects of topical dorzolamide on IOP after phacoemulsification with different types of ophthalmic viscosurgical devices", Eur J Ophthalmol, 17, pp.38~44 (2007)
- Wedrich A, "Intraocular pressure following smallincision cataract surgery and polyHEMA posterior chamber lens implantation.A comparison between acetylcholine and carbachol", J Cataract Refract Surg, 18, pp.500~505 (1992)
- Kohnen T, "Evaluation of intraocular pressure with Healon and Healon GV in sutureless cataract surgery with foldable lens implantation", J Cataract Refract Surg, 22, pp.227~237 (1996)
- Jacobi PC, "Effect of trabecular aspiration on early intraocular pressure rise after cataract surgery", J Cataract Refract Surg, 23, pp.923~929 (1997)
- Nayak BK, "Comparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device:randomized controlled trial", Indian J Ophthalmol, 57, pp.99~103 (2009)
- Pinter SM, "Phacoemulsification in eyes with past pars plana vitrectomy:case-control study", J Cataract Refract Surg, 25, pp.556~561 (1999)
- Smiddy WE, "Cataract extraction after vitrectomy", Ophthalmology, 94, pp.483~487 (1987)
- Apple DJ, "Posterior capsule opacification", Surv Ophthalmol, 37, pp.73~116 (1992)
