Comparison of Each Eye According to the Order of Noninvasive Keratographic Tear Film Evaluation
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To investigate the effect of order of examination on the results of noninvasive keratograph tear film evaluation usingKeratograph5M in dry eye patients. Methods: One hundred and four patients with dry eye symptoms were analyzed retrospectively. All patients underwentbilateral noninvasive tear film evaluation using measurements of tear meniscus height (TMH) and noninvasive keratographbreak-up time (NIKBUT) obtained using Keratograph5M. Measurements were performed sequentially in the order of rightTMH, left TMH, right NIKBUT, and left NIKBUT. Results: There was no statistically significant difference in TMH values between the right and left eyes (0.24 ± 0.08 and 0.23± 0.08 mm, respectively). Mean NIKBUT-first (time at first tear film break-up) and mean NIKBUT-average (the mean of all tearfilm break-up time over the entire cornea) were 6.17 ± 3.28 and 10.00 ± 3.97 seconds, respectively, for right, and 7.43 ± 3.86and 11.57 ± 4.34 seconds, respectively, for left eyes. In addition, mean NIKBUT-first between right and left eyes, and meanNIKBUT-average between them were statistically significant (p = 0.013 and p = 0.007, respectively). Mean NIKBUT and meanTMH differences were not significantly influenced by right or left eyes, age, or sex (all p > 0.050). Spearman correlation analysesof TMH, NIKBUT-first, and NIKBUT-average results showed moderate positive correlations between right and left eyes(r = 0.470, r = 0.322, and r = 0.576, respectively; p < 0.001). Conclusions: TMH evaluation was not affected by test order; however, NIKBUT measurement was affected by test order,because of reflex tearing due to forced eye opening during the examination. Therefore, TMH should be evaluated before NIKBUT,and sufficient time interval and caution should be needed between NIKBUT measurements on both eyes.
Abstract
Purpose: To investigate the effect of order of examination on the results of noninvasive keratograph tear film evaluation usingKeratograph5M in dry eye patients. Methods: One hundred and four patients with dry eye symptoms were analyzed retrospectively. All patients underwentbilateral noninvasive tear film evaluation using measurements of tear meniscus height (TMH) and noninvasive keratographbreak-up time (NIKBUT) obtained using Keratograph5M. Measurements were performed sequentially in the order of rightTMH, left TMH, right NIKBUT, and left NIKBUT. Results: There was no statistically significant difference in TMH values between the right and left eyes (0.24 ± 0.08 and 0.23± 0.08 mm, respectively). Mean NIKBUT-first (time at first tear film break-up) and mean NIKBUT-average (the mean of all tearfilm break-up time over the entire cornea) were 6.17 ± 3.28 and 10.00 ± 3.97 seconds, respectively, for right, and 7.43 ± 3.86and 11.57 ± 4.34 seconds, respectively, for left eyes. In addition, mean NIKBUT-first between right and left eyes, and meanNIKBUT-average between them were statistically significant (p = 0.013 and p = 0.007, respectively). Mean NIKBUT and meanTMH differences were not significantly influenced by right or left eyes, age, or sex (all p > 0.050). Spearman correlation analysesof TMH, NIKBUT-first, and NIKBUT-average results showed moderate positive correlations between right and left eyes(r = 0.470, r = 0.322, and r = 0.576, respectively; p < 0.001). Conclusions: TMH evaluation was not affected by test order; however, NIKBUT measurement was affected by test order,because of reflex tearing due to forced eye opening during the examination. Therefore, TMH should be evaluated before NIKBUT,and sufficient time interval and caution should be needed between NIKBUT measurements on both eyes.
참고문헌 (31)
- Craig JP, "TFOS DEWS II definition and classification report", Ocul Surf, 15, pp.276~283 (2017)
- Jacobi C, "Ophthalmological complications in Sjogren’s syndrome", Z Rheumatol, 69, pp.32~40 (2010)
- Messmer EM, "The pathophysiology, diagnosis, and treatment of dry eye disease", Dtsch Arztebl Int, 112, pp.71~81 (2015)
- Mengher LS, "A non-invasive instrument for clinical assessment of the pre-corneal tear film stability", Curr Eye Res, 4, pp.1~7 (1985)
- Doughty MJ, "Video-assessment of tear meniscus height in elderly Caucasians and its relationship to the exposed ocular surface", Curr Eye Res, 22, pp.420~426 (2001)
- 전수지, "마이봄샘 기능 이상 환자에서 빛간섭단층촬영을 이용한 눈물띠 분석", 대한안과학회지, 56(11), pp.1684~1691 (2015), 대한안과학회
- Wang MT, "Comparative evaluation of clinical methods of tear film stability assessment : a randomized crossover trial", JAMA Ophthalmol, 136, pp.291~294 (2018)
- Koh S, "Effect of non-invasive tear stability assessment on tear meniscus height", Acta Ophthalmol, 93, pp.e135~9 (2015)
- 현준영, "Korean Guidelines for the Diagnosis and Management of Dry Eye: Development and Validation of Clinical Efficacy", Korean Journal of Ophthalmology, 28(3), pp.197~206 (2014), 대한안과학회
- Abdelfattah NS, "Noninvasive imaging of tear film dynamics in eyes with ocular surface disease", Cornea, 34(Suppl 10), pp.S48~52 (2015)
- Lee KW, "Assessment of the tear meniscus by strip meniscometry and keratograph in patients with dry eye disease according to the presence of meibomian gland dysfunction", Cornea, 36, pp.189~195 (2017)
- Arriola-Villalobos P, "Assessment of lower tear meniscus measurements obtained with Keratograph and agreement with Fourier-domain optical-coherence tomography", Br J Ophthalmol, 99, pp.1120~1125 (2015)
- Kim J, "Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes", Acta Ophthalmol, 97, pp.e1089~97 (2019)
- Jiang Y, "Noninvasive Keratograph assessment of tear film break-up time and location in patients with age-related cataracts and dry eye syndrome", J Int Med Res, 42, pp.494~502 (2014)
- Jung JW, "Assessment of meibomian glands and tear film in post-refractive surgery patients", Clin Exp Ophthalmol, 45, pp.857~866 (2017)
- Lee R, "Agreement of noninvasive tear break-up time measurement between Tomey RT-7000Auto Refractor-Keratometer and Oculus Keratograph 5M", Clin Ophthalmol, 10, pp.1785~1790 (2016)
- Holly FJ, "Physical chemistry of the normal and disordered tear film", Trans Ophthalmol Soc U K(1962), 104(Pt 4), pp.374~380 (1985)
- Mishima S, "The tear flow dynamics in normal and keratoconjunctivitis sicca cases", Excerpta Medica Int Congr Ser, 222, pp.1801~1805 (1970)
- Mainstone JC, "Tear meniscus measurement in the diagnosis of dry eye", Curr Eye Res, 15, pp.653~661 (1996)
- Lim KJ, "Measurement of the tear meniscus height using 0.25% f luorescein sodium", Korean J Ophthalmol, 5, pp.34~36 (1991)
- Shen M, "Upper and lower tear menisci in the diagnosis of dry eye", Invest Ophthalmol Vis Sci, 50, pp.2722~2726 (2009)
- Yuan Y, "Reduced tear meniscus dynamics in dry eye patients with aqueous tear deficiency", Am J Ophthalmol, 149, pp.932~938 (2010)
- Palakuru JR, "Effect of blinking on tear dynamics", Invest Ophthalmol Vis Sci, 48, pp.3032~3037 (2007)
- Li J, "Clinical significance of tear menisci in dry eye", Eye Contact Lens, 38, pp.183~187 (2012)
- Cui L, "Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye", Eye Contact Lens, 38, pp.240~244 (2012)
- Bron AJ, "TFOS DEWS II pathophysiology report", Ocul Surf, 15, pp.438~510 (2017)
- Norn MS, "Desiccation of the precorneal film. I. Corneal wetting-time", Acta Ophthalmol(Copenh), 47, pp.865~880 (1969)
- Garcia-Resua C, "Clinical assessment of the lower tear meniscus height", Ophthalmic Physiol Opt, 29, pp.487~496 (2009)
- Lam AK, "Lower tear meniscus height measurements using keratography and swept-source optical coherence tomography and effect of fluorescein instillation methods", Curr Eye Res, 44, pp.1203~1208 (2019)
- Goto T, "Tear film stability analysis system : introducing a new application for videokeratography", Cornea, 23(8 Suppl), pp.S65~70 (2004)
- Tian L, "Repeatability and reproducibility of noninvasive keratograph 5m measurements in patients with dry eye disease", J Ophthalmol, 2016, pp.8013621~ (2016)
