Purpose: To evaluate the usefulness of a newly generated monofocal intraocular lens (IOL) in patients with various retinal diseases who underwent combined cataract and pars plana vitrectomy surgery. Methods: This prospective observational study included 33 patients with various retinal diseases. Monocular best-corrected distance visual acuity (BCDVA), uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), and contrast sensitivity were measured and compared with 40 age-matched patients in the standard monofocal IOL. Results: The Eyhance IOL group demonstrated significantly better UCIVA at 6 months follow-up compared to the standard monofocal IOL group. No significant differences were observed between the two groups in contrast sensitivity, BCDVA, UCDVA, or UCNVA. The regression analysis showed a significant association between preoperative corrected distance visual acuity and improved UCIVA in the Eyhance IOL group. Conclusions: The Eyhance ICB00 IOL proved to be a valuable option for patients with retinal diseases undergoing combined cataract surgery and vitrectomy. It effectively improved intermediate vision without compromising contrast sensitivity or distance visual acuity.
Abstract
Purpose: To evaluate the usefulness of a newly generated monofocal intraocular lens (IOL) in patients with various retinal diseases who underwent combined cataract and pars plana vitrectomy surgery. Methods: This prospective observational study included 33 patients with various retinal diseases. Monocular best-corrected distance visual acuity (BCDVA), uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), and contrast sensitivity were measured and compared with 40 age-matched patients in the standard monofocal IOL. Results: The Eyhance IOL group demonstrated significantly better UCIVA at 6 months follow-up compared to the standard monofocal IOL group. No significant differences were observed between the two groups in contrast sensitivity, BCDVA, UCDVA, or UCNVA. The regression analysis showed a significant association between preoperative corrected distance visual acuity and improved UCIVA in the Eyhance IOL group. Conclusions: The Eyhance ICB00 IOL proved to be a valuable option for patients with retinal diseases undergoing combined cataract surgery and vitrectomy. It effectively improved intermediate vision without compromising contrast sensitivity or distance visual acuity.
참고문헌 (20)
- Bellucci R, "Multifocal intraocular lenses", Curr Opin Ophthalmol, 16, pp.33~37 (2005)
- Dick HB, "Accommodative intraocular lenses : current status", Curr Opin Ophthalmol, 16, pp.8~26 (2005)
- Kamath GG, "Visual outcome with the array multifocal intraocular lens in patients with concurrent eye disease", J Cataract Refract Surg, 26, pp.576~581 (2000)
- Gayton JL, "Implantation of multifocal intraocular lenses using a magnification strategy in cataractous eyes with age-related macular degeneration", J Cataract Refract Surg, 38, pp.415~418 (2012)
- Sokol S, "Contrast sensitivity in diabetics with and without background retinopathy", Arch Ophthalmol, 103, pp.51~54 (1985)
- Tognetto D, "Surface profiles of new-generation IOLs with improved intermediate vision", J Cataract Refract Surg, 46, pp.902~906 (2020)
- Mencucci R, "Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results", J Cataract Refract Surg, 46, pp.378~387 (2020)
- Unsal U, "Comparison of new monofocal innovative and standard monofocal intraocular lens af ter phacoemulsification", Int Ophthalmol, 41, pp.273~282 (2021)
- Auffarth GU, "Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract", J Cataract Refract Surg, 47, pp.184~191 (2021)
- Cinar E, "Vision outcomes with a new monofocal IOL", Int Ophthalmol, 41, pp.491~498 (2021)
- Lopes D, "Comparative evaluation of visual outcomes after bilateral implantation of an advanced or conventional monofocal intraocular lens", Eur J Ophthalmol, 32, pp.229~234 (2022)
- Aptel F, "Management of postoperative inflammation after cataract and complex ocular surgeries : a systematic review and Delphi survey", Br J Ophthalmol, 101, pp.1451~1460 (2017)
- Vega F, "Optical performance of a monofocal intraocular lens designed to extend depth of focus", J Refract Surg, 36, pp.625~632 (2020)
- Cao K, "Multifocal versus monofocal intraocular lenses for age-related cataract patients : a system review and meta-analysis based on randomized controlled trials", Surv Ophthalmol, 64, pp.647~658 (2019)
- Patel SB, "Combined phacoemulsification surgery with multifocal intraocular lens implantation and pars plana vitrectomy for symptomatic vitreous opacities", Retin Cases Brief Rep, 15, pp.724~729 (2021)
- Altun A, "Comparing the effect of monofocal and multifocal intraocular lenses on macular surgery", J Ophthalmol, 2020, pp.1375298~ (2020)
- Gibbons A, "Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses", Clin Ophthalmol, 10, pp.1965~1970 (2016)
- de Vries NE, "Dissatisfaction after implantation of multifocal intraocular lenses", J Cataract Refract Surg, 37, pp.859~865 (2011)
- Abou-Shousha M, "The accuracy of axial length measurements in cases of macula-off retinal detachment", Can J Ophthalmol, 51, pp.108~112 (2016)
- Sakamoto M, "Postoperative refractive prediction error measured by optical and acoustic biometry after phacovitrectomy for rhegmatogenous retinal detachment without macular involvement", J Ophthalmol, 2019, pp.5964127~ (2019)