One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population
3
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UTDSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population. Methods: This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed. Results: At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 μm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D. Conclusions: The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.
Abstract
Purpose: To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UTDSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population. Methods: This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed. Results: At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 μm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D. Conclusions: The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.
참고문헌 (29)
- Melles GR, "A surgical technique for posterior lamellar keratoplasty", Cornea, 17, pp.618~626 (1998)
- Singh R, "Corneal transplantation in the modern era", Indian J Med Res, 150, pp.7~22 (2019)
- Gorovoy MS, "Descemet-stripping automated endothelial keratoplasty", Cornea, 25, pp.886~889 (2006)
- Koenig SB, "Early results of small-incision Descemet’s stripping and automated endothelial keratoplasty", Ophthalmology, 114, pp.221~226 (2007)
- Lee WB, "Descemet’s stripping endothelial keratoplasty : safety and outcomes : a report by the American Academy of Ophthalmology", Ophthalmology, 116, pp.1818~1830 (2009)
- Stuart AJ, "Descemet’s membrane endothelial keratoplasty(DMEK)versus Descemet’s stripping automated endothelial keratoplasty(DSAEK)for corneal endothelial failure", Cochrane Database Syst Rev, 6, pp.CD012097~ (2018)
- Deng SX, "Descemet membrane endothelial keratoplasty : safety and outcomes : a report by the American Academy of Ophthalmology", Ophthalmology, 125, pp.295~310 (2018)
- Singh A, "Systematic review and meta-analysis of clinical outcomes of descemet membrane endothelial keratoplasty versus Descemet stripping endothelial keratoplasty", descemet stripping automated endothelial keratoplasty, 2017, pp.36, 1437~1443
- Busin M, "Microkeratome-assisted preparation of ultrathin grafts for Descemet stripping automated endothelial keratoplasty", Invest Ophthalmol Vis Sci, 53, pp.521~524 (2012)
- Dunker SL, "Descemet membrane endothelial keratoplasty versus ultrathin Descemet stripping automated endothelial keratoplasty : a multicenter randomized controlled clinical trial", Ophthalmology, 127, pp.1152~1159 (2020)
- Covert DJ, "New triple procedure : Descemet’s stripping and automated endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation", Ophthalmology, 114, pp.1272~1277 (2007)
- Dupps WJ Jr, "Multivariate model of refractive shift in Descemet-stripping automated endothelial keratoplasty", J Cataract Refract Surg, 34, pp.578~584 (2008)
- Ham L, "Refractive change and stability after Descemet membrane endothelial keratoplasty : effect of corneal dehydration-induced hyperopic shift on intraocular lens power calculation", J Cataract Refract Surg, 37, pp.1455~1464 (2011)
- Holz HA, "Corneal profile analysis after Descemet stripping endothelial keratoplasty and its relationship to postoperative hyperopic shift", J Cataract Refract Surg, 34, pp.211~214 (2008)
- Jun B, "Refractive change after Descemet stripping automated endothelial keratoplasty surgery and its correlation with graft thickness and diameter", Cornea, 28, pp.19~23 (2009)
- van Dijk K, "Near complete visual recovery and refractive stability in modern corneal transplantation : Descemet membrane endothelial keratoplasty(DMEK)", Cont Lens Anterior Eye, 36, pp.13~21 (2013)
- van Dijk K, "Two-year refractive outcomes after Descemet membrane endothelial keratoplasty", Cornea, 35, pp.1548~1555 (2016)
- Sarnicola V, "Suture pullthrough insertion of graft donor in Descemet stripping automated endothelial keratoplasty : results of 4-year follow-up", Taiwan J Ophthalmol, 5, pp.114~119 (2015)
- Yoo SH, "One-year results and anterior segment optical coherence tomography findings of Descemet stripping automated endothelial keratoplasty combined with phacoemulsification", Arch Ophthalmol, 126, pp.1052~1055 (2008)
- Chamberlain W, "Changes in corneal power up to 2 years after endothelial keratoplasty : results from the randomized controlled Descemet endothelial thickness comparison trial", Am J Ophthalmol, 245, pp.233~241 (2023)
- Terry MA, "Endothelial keratoplasty for Fuchs’ dystrophy with cataract : complications and clinical results with the new triple procedure", Ophthalmology, 116, pp.631~639 (2009)
- Schoenberg ED, "Refractive outcomes of Descemet membrane endothelial keratoplasty triple procedures(combined with cataract surgery)", J Cataract Refract Surg, 41, pp.1182~1189 (2015)
- Laaser K, "Descemet membrane endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation : advanced triple procedure", Am J Ophthalmol, 154, pp.47~55 (2012)
- Geggel HS, "Intraocular lens implantation after penetrating keratoplasty: improved unaided visual acuity, astigmatism, and safety in patients with combined corneal disease and cataract", Ophthalmology, 97, pp.1460~1467 (1990)
- Ozbek Uzman S, "Corneal pathology and cataract : combined surgery or sequential surgery?", Turk J Ophthalmol, 51, pp.1~6 (2021)
- Pineros OE, "Triple vs nonsimultaneous procedures in Fuchs’ dystrophy and cataract", Arch Ophthalmol, 114, pp.525~528 (1996)
- Han YE, "Clinical outcomes of nanothin Descemet stripping automated endothelial keratoplasty in Korean patients with corneal endothelial dysfunction", Korean J Ophthalmol, 36, pp.131~137 (2022)
- Romano V, "Combined or sequential DMEK in cases of cataract and Fuchs endothelial corneal dystrophy : a systematic review and meta-analysis", Acta Ophthalmol, 102, pp.e22~e30 (2024)
- Clemmensen K, "Changes in corneal power after Descemet stripping automated endothelial keratoplasty", J Refract Surg, 31, pp.807~812 (2015)
