A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.
Abstract
A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.
참고문헌 (11)
- Suppression of shipboard fires in large volume spaces using monitors, "Back, Gerard G.", National Research Laboratory, ~ (2015)
- Tao Chen, "An automatic fire searching and suppression system for large spaces", Fire Safety Journal, 39(4), pp.297~307 (2004), Elsevier BV[DOI]
- 최병일, "선박기관구역 미분무수 소화설비 화재진압 성능 평가", 한국화재소방학회 논문지, 21(2), pp.111~117 (2007), 한국화재소방학회
- "Full line catalogue F8.1"[URL]
- "Performance documents of monitors and master stream"[URL]
- 임다빈, "파랑 중 운동하는 선박 내부 소화 모니터의 소화수 거동 모델링", 한국CDE학회 논문집, 26(1), pp.50~58 (2021), 한국CDE학회[DOI]
- "analysis of water discharge trajectory with large capacity monitor"[URL]
- 정인수, "선박 거주구역용 소화시스템의 전산 시뮬레이션", 한국전산유체공학회지, 21(4), pp.40~45 (2016), 한국전산유체공학회[DOI]
- Joshua G. McNeil, "Autonomous Fire Suppression System for Use in High and Low Visibility Environments by Visual Servoing", Fire Technology, 52(5), pp.1343~1368 (2016), Springer Science and Business Media LLC[DOI]
- Tatsuya Miyashita, "Modeling and analysis of water discharge trajectory with large capacity monitor", Fire Safety Journal, 63, pp.1~8 (2014), Elsevier BV[DOI]
- 박진욱, "복층터널 화재대응을 위한 원격 자동소화시스템 개발 연구", 한국터널지하공간학회 논문집, 21(1), pp.167~175 (2019), 사단법인 한국터널지하공간학회[DOI]