53ft 액화천연가스 탱크 컨테이너의 정적 구조 강도 평가에 관한 연구
A Study on the Static Structural Strength Evaluation of 53ft Liquefied Natural Gas Tank Container
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University's Subsea Umbilical cable Riser Flowline R&D Center, which provided a suitable testing environment. The study found that calculated stresses met the allowable stress under specified load conditions, confirming the structural safety of the tank container. Additionally, the maximum deformation and permanent deformation satisfied the design criteria for all test cases, indicating the container's structural strength meets requirements. The research also contributed valuable data for future structural strength tests of similar products and facilitated the development of safe and efficient LNG transportation solutions by developing effective test procedures in accordance with ISO 1496-3 standards.
Abstract
This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University's Subsea Umbilical cable Riser Flowline R&D Center, which provided a suitable testing environment. The study found that calculated stresses met the allowable stress under specified load conditions, confirming the structural safety of the tank container. Additionally, the maximum deformation and permanent deformation satisfied the design criteria for all test cases, indicating the container's structural strength meets requirements. The research also contributed valuable data for future structural strength tests of similar products and facilitated the development of safe and efficient LNG transportation solutions by developing effective test procedures in accordance with ISO 1496-3 standards.
참고문헌 (19)
- American Bureau of Shipping (ABS), "Guide for liquefied gas carriers with independent tanks" (2019), ABS
- American Society of Mechanical Engineers(ASME), "AN International code 2019 ASME boiler & pressure vessel code VIII rules for construction of pressure vessels division 1" (2019), ASME
- Portable tank specification Transport Canada (TC) 44 CSA B626-09, "Canadian Standards Association(CSA)Group", CSA Group, ~ (2009)
- 최훈석, "Cold Stretching 압력용기용 ASS304 소재의 극저온 인장 및 피로거동", 대한기계학회논문집 A, 40(5), pp.429~435 (2016), 대한기계학회
- International Maritime Organization(IMO), "The international Convention for Safe Containers (CSC) annex I &II" (1972), IMO
- International Maritime Dangerous Goods (IMDG) Code 6.7.2, 6.7.3, and 6.7.4, "International Maritime Organization(IMO)", IMO, ~ (2018)
- Series 1 freight containers - specification and testing -Part 3: tank containers for liquids, gases and pressurized dry bulk, "International Organization for Standardization(ISO)", ISO, ~ (2019)
- Jeon, E. K., "A study of consequence analysis for gas leakage of mobile LNG filling station", Academic Presentation of the Korea Energy Engineering Association, pp.183~183 (2022)
- 김태우, "LNG 연료 추진선의 연료 탱크로서 탱크컨테이너의 적용성 연구 및 구조설계", 대한조선학회 논문집, 49(6), pp.504~511 (2012), 대한조선학회
- Kim, J. S., "Impact test method of tank container using full-scale crash test facilities for a train", Korea Automotive Engineering Association General Conference, 5, pp.2127~2132 (2013)
- Kim, K. D., "Analysis of overseas small scale LNG trend and implications", Journal of the Korea Gas Society, 5, pp.163~163 (2018)
- Report of type approval test for freight container-general information CTR5, "Korea Register(KR)", KR, ~ (2017)
- Lee, Y. H., "An analysis of safety and feasibility for a transfer equipment of LNG tank containers", Journal of the Korea Gas Society, 11, pp.85~85 (2014)
- Report on the investigation into the loss of 137 containers from the container ship CMA CGM G, "Marine Accident Investigation Branch (MAIB)", MAIB, ~ (2018)
- Application of environment-friendly LNG vehicle distribution and smallscale LNG logistics KGU newsletter Vol.4, "Korea Gas Corporation(KOGAS)", KOGAS, ~ (2019)
- Park, K. I., "Strategies for the LNG supply on island area using a ISO tank containers", Journal of the Korea Gas Society, 6, pp.69~69 (2016)
- Global LNG ISO tank container market research report 2020, "QYResearch Korea", QYResearch Korea, ~ (2020)
- Ryu, Y. D., "Study on small scale LNG supply and LNG as fuel", Academic Presentation of the Korea Energy Engineering Association, 11, pp.78~78 (2013)
- 류영돈, "이동식 LNG 야드트랙터 충전 기준 개발 연구", 한국가스학회지, 22(6), pp.59~64 (2018), 한국가스학회[DOI]