도시 협곡에서 건물 지붕 냉각이 스칼라 물질 확산에 미치는 영향
Effects of Building-roof Cooling on Scalar Dispersion in Urban Street Canyons
2
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
In this study, the effects of building-roof cooling on scalar dispersion in threedimensionalstreet canyons are investigated using a computational fluid dynamics (CFD)model. For this, surface temperature of building roof is systematically changed and non-reactivepollutants are released from street bottom in urban street canyons with the aspect ratio of1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the controlexperiment are analyzed first. Then, the effects of building-roof cooling are investigated bycomparing the results with those in the control experiment. In the control experiment, a portalvortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon,because warmer air is coming into the street canyon from the roof level. However, airtemperature near the street bottom is lower inside the street canyon due to the inflow of coolerair from both sides of the street canyon. As building-roof temperature decreases, wind speed atthe roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow,and updraft becomes stronger). Building-roof cooling contributes to the reduction of averageconcentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermalenvironment and air quality in urban areas.
Abstract
In this study, the effects of building-roof cooling on scalar dispersion in threedimensionalstreet canyons are investigated using a computational fluid dynamics (CFD)model. For this, surface temperature of building roof is systematically changed and non-reactivepollutants are released from street bottom in urban street canyons with the aspect ratio of1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the controlexperiment are analyzed first. Then, the effects of building-roof cooling are investigated bycomparing the results with those in the control experiment. In the control experiment, a portalvortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon,because warmer air is coming into the street canyon from the roof level. However, airtemperature near the street bottom is lower inside the street canyon due to the inflow of coolerair from both sides of the street canyon. As building-roof temperature decreases, wind speed atthe roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow,and updraft becomes stronger). Building-roof cooling contributes to the reduction of averageconcentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermalenvironment and air quality in urban areas.
참고문헌 (39)
- Alexandria, E., "Temperature decreases Fig. 13. Variation of air temperature and non-dimensional concentration averaged over the street canyon with buildingroof cooling. in an urban canyon due to green walls and green roofs in diverse climates", Build. Environ., 43, pp.480~493 (2008)
- Asaeda, T., "Heat storage of pavement and its effect on the lower atmosphere", Atmos. Environ., 30, pp.413~427 (1996)
- Baik, J. J., "On the escape of pollutants from urban street canyons", Atmos. Environ., 36, pp.527~536 (2002)
- Baik, J. J., "Urban flow and dispersion simulation using a CFD model coupled to a mesoscale model", J. Appl. Meteor. Climatol., 48, pp.1667~1681 (2009)
- Baik, J. J., "Effects of building roof greening on air quality in street canyons", Atmos. Environ., 61, pp.48~55 (2012)
- Castro, I. P., "Flow and dispersion over topography: a comparison between numerical and laboratory data for two-dimensional flows", Atmos. Environ., 31, pp.893~850 (1997)
- Giridharan, R., "Urban design factors influencing heat island intensity in high-rise high-density environments of Hong Kong", Build. Environ., 42, pp.3669~3684 (2007)
- Huang, H., "CFD analysis on traffic-induced air pollutant dispersion under non-isothermal condition in a complex urban area in water", J. Wind Eng. Ind. Aerodynamics, 96, pp.1774~1788 (2008)
- Kang, Y. S., "Further studies of flow and reactive pollutant dispersion in a street canyon with bottom heating", Atmos. Environ., 42, pp.4964~4975 (2008)
- 김현옥, "도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로", 대한원격탐사학회지, 28(2), pp.203~214 (2012), 대한원격탐사학회[DOI]
- 김재진, "장애물 외관비가 주변 흐름에 미치는 영향", 대기, 17(4) (2007), 한국기상학회
- Kim, J. J., "Physical experiments to investigate the effects of street bottom heating and inflow turbulence on urban street-canyon flow", Adv. Atmos. Sci., 22, pp.230~237 (2005)
- Kim, J. J., "Effects of street-bottom and building-roof heating on flow in three-dimensional street canyons", Adv. Atmos. Sci., 27, pp.513~527 (2010)
- Kim, J. J., "Two-dimensional numerical modeling of flow and dispersion in the presence of hill and buildings", J. Wind Eng. Ind. Aerodynamics, 89, pp.947~966 (2001)
- 김재진, "Effects of Building-Roof Cooling on Flow and Air Temperature in Urban Street Canyons", 한국기상학회지, 50(3), pp.365~375 (2014), 한국기상학회
- 김수봉, "대구광역시 중구의 가로수 및 열섬 모자이크 현황 분석", 한국환경과학회지, 15(4), pp.325~332 (2006), 한국환경과학회
- Kolokotroni, M., "Urban heat island intensity in London: An investigation of the impact of physical characteristics on changes in outdoor air temperature during summer", Solar Energy, 82, pp.986~998 (2008)
- 이동근, "옥상녹화조성에 따른 온도저감효과에 관한 연구-서울대학교 실험구를 중심으로-", 한국환경복원기술학회지, 8(6), pp.34~44 (2005), 한국환경복원기술학회
- 이응직, "옥상녹화와 비 옥상녹화 표면의 온도변화 상관관계 고찰 -대전지역을 중심으로-", 한국태양에너지학회 논문집, 32(6), pp.134~140 (2012), 한국태양에너지학회
- Lee, K. G., "The study on the heat island and cool island according to trend toward higher temperature in urban: Case study oh Taegu metropolitian city", J. Archit. Inst. Korean, 23, pp.219~228 (2007)
- 이우성, "친환경적 공간계획을 위한 도시의 열환경 분석", 한국지리정보학회지, 13(1), pp.142~154 (2010), 한국지리정보학회
- Niachou, A., "Analysis of the green roof thermal properties and investigation of its energy performance", Energ. Buildings, 33, pp.719~729 (2001)
- Offerle, B., "Surface heating in relation to air temperature, wind and turbulence in an urban street canyon", Bound.-Layer Meteor., 122, pp.273~292 (2007)
- 박석봉, "광주지역의 여름철 열섬현상 측정 및 분석", 한국태양에너지학회 논문집, 24(4), pp.65~75 (2004), 한국태양에너지학회
- Patankar, S. V., "Numerical Heat Transfer and Fluid Flow", pp.197~ (1980), McGraw-Hill
- Pavageau, M., "Wind tunnel measurements of concentration fluctuations in an urban street canyon", Atmos. Environ., 33, pp.3961~3971 (1999)
- Rosenfeld, A. H., "Mitigation of urban heat islands: materials, utility program, updates", Energ. Buildings, 22, pp.255~265 (1995)
- Santamouris, M., "On the impact of urban climate on the energy consumption of buildings", Solar Energy, 70, pp.201~216 (2001)
- Schlünzen, K. H., "Flow and transport in the obstacle layer: First results of the microscale model MITRAS", J. Atmos. Chem., 44, pp.113~130 (2003)
- Shashua-Bar, L., "The Green CTTC model for predicting the air temperature in small urban wooded sites", Build. Environ., 37, pp.1279~1288 (2002)
- Sini, J. F., "Pollutant dispersion and thermal effects in urban street canyons", Atmos. Environ., 30, pp.2659~2677 (1996)
- Takahashi, K., "Measurement of thermal environment in Kyoto city and its prediction by CFD simulation", Energ. Buildings, 36, pp.771~779 (2004)
- Tewari, M., "Impact of coupling a microscale computational fluid dynamics model with a mesoscale model on urban scale contaminant transport and dispersion", Atmos. Res., 96, pp.656~664 (2010)
- Theodosiou, T. G., "Summer period analysis of the performance of a planted roof as a passive cooling technique", Energ. Buildings, 35, pp.909~917 (2003)
- Voogt, J. A., "Effects of urban surface geometry on remotely sensed surface temperature", Int. J. Remote Sens., 19, pp.895~920 (1998)
- Versteeg, H. K., "An Introduction to Computational Fluid Dynamics: The Finite Volume Method", pp.257~ (1995), Longman
- Wong, N. H., "Investigation of thermal benefits of rooftop garden in the tropical environment", Build. Environ., 38, pp.261~270 (2003)
- Yakhot, V., "Development of turbulence models for shear flows by a double expansion technique", Physics of Fluids, 4, pp.1510~1520 (1992)
- Yeo, I. A., "Numerical simulation on the urban heat island effect formed by urban planning elements in summer", J. Archit. Inst. Korean, 29, pp.557~580 (2009)