The purpose of this study is to build urban canopy model (Met Office Reading Urban Surface Exchange Scheme, MORUSES) based to Unified Model (UM) by using urban building information data in Seoul, and then to compare the improving urban canopy model simulation result with that of Seoul Automatic Weather Station (AWS) observation site data. UM-MORUSES is based on building information database in London, we performed a sensitivity experiment of UM-MOURSES model using urban building information database in Seoul. Geographic Information System (GIS) analysis of 1.5 km resolution Seoul building data is applied instead of London building information data. Frontal-area index and planar-area index of Seoul are used to calculate building height. The height of the highest building in Seoul is 40m, showing high in Yeoido-gu, Gangnam-gu and Jamsil-gu areas. The street aspect ratio is high in Gangnam-gu, and the repetition rate of buildings is lower in Eunpyeong-gu and Gangbuk-gu. UM-MORUSES model is improved to consider the building geometry parameter in Seoul. It is noticed that the Root Mean Square Error (RMSE) of wind speed is decreases from 0.8 to 0.6 m s1 by 25 number AWS in Seoul. The surface air temperature forecast tends to underestimate in pre-improvement model, while it is improved at night time by UM-MORUSES model. This study shows that the post-improvement UM-MORUSES model can provide detailed Seoul building information data and accurate surface air temperature and wind speed in urban region.
Abstract
The purpose of this study is to build urban canopy model (Met Office Reading Urban Surface Exchange Scheme, MORUSES) based to Unified Model (UM) by using urban building information data in Seoul, and then to compare the improving urban canopy model simulation result with that of Seoul Automatic Weather Station (AWS) observation site data. UM-MORUSES is based on building information database in London, we performed a sensitivity experiment of UM-MOURSES model using urban building information database in Seoul. Geographic Information System (GIS) analysis of 1.5 km resolution Seoul building data is applied instead of London building information data. Frontal-area index and planar-area index of Seoul are used to calculate building height. The height of the highest building in Seoul is 40m, showing high in Yeoido-gu, Gangnam-gu and Jamsil-gu areas. The street aspect ratio is high in Gangnam-gu, and the repetition rate of buildings is lower in Eunpyeong-gu and Gangbuk-gu. UM-MORUSES model is improved to consider the building geometry parameter in Seoul. It is noticed that the Root Mean Square Error (RMSE) of wind speed is decreases from 0.8 to 0.6 m s1 by 25 number AWS in Seoul. The surface air temperature forecast tends to underestimate in pre-improvement model, while it is improved at night time by UM-MORUSES model. This study shows that the post-improvement UM-MORUSES model can provide detailed Seoul building information data and accurate surface air temperature and wind speed in urban region.
참고문헌 (20)
- M. J. Best, "The Joint UK Land Environment Simulator (JULES), model description – Part 1: Energy and water fluxes", Geoscientific Model Development, 4(3), pp.677~699 (2011), Copernicus GmbH[DOI]
- S. I. Bohnenstengel, "Simulations of the London urban heat island", Quarterly Journal of the Royal Meteorological Society, 137(659), pp.1625~1640 (2011), Wiley[DOI]
- 변재영, "WRF-UCM (Urban Canopy Model)을 이용한 서울 지역의 도시기상 예보 평가", 대기, 20(1), pp.13~26 (2010), 한국기상학회
- M. Roth, "The integrated WRF", urban modelling system: development, evaluation, and applications to urban environmental problems, 2011, pp.31(2), 273~288[DOI]
- Davies, T., "A new dynamical core for the Met Office’s global and regional modelling of the atmosphere", Q. J. R. Meteorol. Soc, 131, pp.1759~1782 (2005)
- Edwards, J. M., "Studies with a flexible new radiation code. I: Choosing a configuration for a large-scale model", Q. J. R. Meteorol. Soc, 122, pp.689~719 (1996)
- 홍선옥, "통합모델을 이용한 토지피복변화와 도시 모수화 방안에 따른지상 기온 모의성능 민감도 분석", 대기, 28(4), pp.427~441 (2018), 한국기상학회[DOI]
- Kusaka, H., "A simple single-layer urban canopy model for atmospheric models: Comparison with multi-layer and slab models", Bound.-Layer Meteor, 101, pp.329~358 (2001)
- Lee, S. -H., "A vegetated urban canopy model for meteorological and environmental modelling", Bound.-Layer Meteor, 126, pp.73~102 (2008)
- Li, D., "Synergistic interactions between urban heat islands and heat waves: The impact in cities is larger than the sum of its parts", J. Appl. Meteor. Climatol, 52, pp.2051~2064 (2013)
- X. Liang, "SURF: Understanding and Predicting Urban Convection and Haze", Bulletin of the American Meteorological Society, 99(7), pp.1391~1413 (2018), American Meteorological Society[DOI]
- Lock, A. P., "A new boundary layer mixing scheme. Part I: Scheme description and single-column model tests", Mon. Wea. Rev, 128, pp.3187~3199 (2000)
- Masson, V., "A physically-based scheme for the urban energy budget in atmospheric models", Bound.-Layer Meteor, 94, pp.357~397 (2000)
- Integrated Weather Services for Urban and Rural Area(III) - Development of Prediction Model for Urban and Rural Area(III), "NIMR", National Institute of Meteorological Research, 146~160, pp.National Institute of Meteorological Research 11-1360000-0011310-10 (2014)
- Oleson, K. W., "An urban parameterization for a global climate model. Part II: Sensitivity to input parameters and the simulated urban heat island in offline simulations", J. Appl. Meteorol, 47, pp.1061~1076 (2008)
- A. Porson, "Implementation of a new urban energy budget scheme in the MetUM. Part I: Description and idealized simulations", Quarterly Journal of the Royal Meteorological Society, 136(651), pp.1514~1529 (2010), Wiley[DOI]
- Alvin Christopher G. Varquez, "The Effects of Highly Detailed Urban Roughness Parameters on a Sea-Breeze Numerical Simulation", Boundary-Layer Meteorology, 154(3), pp.449~469 (2015), Springer Science and Business Media LLC[DOI]
- Webster, S., "Improvements to the representation of orography in the Met Office Unified Model", Q. J. R. Meteorol. Soc, 129, pp.1989~2010 (2003)
- Wilson, D. R., "A microphysically based precipitation scheme for the UK Meteorological Office Unified Model", Q. J. R. Meteorol. Soc, 125, pp.1607~1636 (1999)
- 이채연, "서울시 건물형태에 따른 거칠기길이 분포특성 연구", 대기, 25(2), pp.339~351 (2015), 한국기상학회