국방 주요 시설의 HEMP 및 IEMI 공격에 대비한 방호용 CCTV 시스템 구축 필요성 제안
Proposal for the need to establish CCTV systems for protection against HEMP and IEMI attacks in major defense facilities
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
A Pulse Current Injection (PCI) experiment was conducted in accordance with the MIL-STD-188-125 standard to test the resistance results of HEMP and IEMI attacks on existing CCTV systems. Experiments have shown that the adapter is broken at the pulse current of 200A and blacked out the surveillance screen. Through further current injection experiments, the monitoring screen was blacked out because the pulse current of 2500A broke not only the adapter and camera but also the input terminals of the DVR. Given the results of these experiments, it is believed that for CCTV systems monitoring external conditions at major defense installations, it is essential to establish CCTV systems for high-power electromagnetic pulse protection against HEMP and IEMI attacks.
Abstract
A Pulse Current Injection (PCI) experiment was conducted in accordance with the MIL-STD-188-125 standard to test the resistance results of HEMP and IEMI attacks on existing CCTV systems. Experiments have shown that the adapter is broken at the pulse current of 200A and blacked out the surveillance screen. Through further current injection experiments, the monitoring screen was blacked out because the pulse current of 2500A broke not only the adapter and camera but also the input terminals of the DVR. Given the results of these experiments, it is believed that for CCTV systems monitoring external conditions at major defense installations, it is essential to establish CCTV systems for high-power electromagnetic pulse protection against HEMP and IEMI attacks.
참고문헌 (8)
- "Information and Communication Terminology Dictionary"[URL]
- "MIL-STD-2169 Revision B: High-Altitude Electromagnetic Pulse(HEMP) Environment", ~ (2012)
- "IEC TR 61000-1-3, Electromagnetic compatibility (EMC)- Part 1-3: General - The effects of high - altitude EMP(HEMP) on civil equipment and systems", ~ (2002)
- "MIL-STD-188-125-1, High-Altitude Electromagnetic Pulse (HEMP) Protection For Ground-Based C4I Facilities Performing Critical, Time-Urgent Missions, Part1: Fixed Facilities", ~ (1998)
- "EMP : formidable weapon to make electronic equipment ‘fool’" (2017)[URL]
- "Have a ‘high electromagnetic wave’ safety manual" (2010)[URL]
- F. Sabath, "What can be learned from documented Intentional Electromagnetic Interference(IEMI)Attacks?", Proc. General Assem. Sci. Symp., 201130th URSI (2011)
- "IEC 61000-4-23 Ed.1.0: Electromagnetic compatibility (EMC) Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances", ~ (2000)