1.5 MW 풍력 터빈 소음 측정 및 저주파 소음 특성 분석
1.5 MW Wind Turbine Noise Measurement and Analysis of Low-Frequency Noise
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The noise from a 1.5 MW wind turbine was measured and the apparent sound power level, tonal audibility, and spectrumbalance were analyzed. The apparent sound power level and tonal audibility were analyzed according to IEC 61400-11: ed3. (2012-11). The measured noise data at the turbine site was mainly in the north-west (NW) and north-north-west (NNW) directions,and approximately 500 and 250 samples of total noise and background noise data were obtained. Three tone components wereobserved in the low frequency region below 100 Hz. The tones in the low frequency critical band with a center frequency of 78.1 Hzwere found to have a higher level than the hearing threshold. The possibility of wind turbine noise annoyance was also analyzedthrough the spectrum balance analysis.
Abstract
The noise from a 1.5 MW wind turbine was measured and the apparent sound power level, tonal audibility, and spectrumbalance were analyzed. The apparent sound power level and tonal audibility were analyzed according to IEC 61400-11: ed3. (2012-11). The measured noise data at the turbine site was mainly in the north-west (NW) and north-north-west (NNW) directions,and approximately 500 and 250 samples of total noise and background noise data were obtained. Three tone components wereobserved in the low frequency region below 100 Hz. The tones in the low frequency critical band with a center frequency of 78.1 Hzwere found to have a higher level than the hearing threshold. The possibility of wind turbine noise annoyance was also analyzedthrough the spectrum balance analysis.
참고문헌 (9)
- Eja Pedersen, "Perception and annoyance due to wind turbine noise—a dose-response relationship", The Journal of the Acoustical Society of America, 116, pp.3460~3470 (2004)
- Seunghoon Lee, "Annoyance caused by amplitude modulation of wind turbine noise", Noise Control Eng. J, 59(1) (2011)
- 정성수, "Experimental Identication of Acoustic Emission Characteristics of Large Wind Turbines with Emphasis on Infrasound and Low-Frequency Noise", Journal of the Korean Physical Society, 53(4), pp.1897~1905 (2008), 한국물리학회
- Con Doolan, "A Review of Wind Turbine Noise Perception, Annoyance and Low Frequency Emission", WIND ENGINEERING, 37(1), pp.97~104 (2013)
- Low Frequency Noise from Large Wind Turbines - A procedure for evaluation of the audibility for low frequency sound and a literature study, "DELTA", DELTA, ~ (2008)
- Bryan, M. E., "Infrasound and Low Frequency Vibration" (1976), Academic Press
- "IEC 61400-11:ed3.(2012-11), Wind turbines -Part 11: Acoustic noise measurement techniques", International Electrotechnical Commission, ~ (2012)
- Henrik Møller, "Low-frequency noise from large wind turbines", J. Acoust. Soc. Am, 129(6) (2011)
- Bill DAWSON, "Tonal characteristics of wind turbine drive trains", Inter-noise, ~ (2014)