The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with 18F FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

Abstract

The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with 18F FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

참고문헌 (23)

  1. Robeson W, "Dosimetry of the dopamine transporter radioligand 18F FP-CIT in human subjects", J Nucl Med, 44(6), pp.961~966 (2003)
  2. 홍석경, "파킨슨병 환자의 삶의 질", 대한신경과학회지, 20(3), pp.227~233 (2002), 대한신경과학회
  3. 전형준, "파킨슨병의 진단에 있어서 123I-IPT SPECT 검사의 임상적 의미", 대한신경외과학회지, 34(2), pp.104~109 (2003), 대한신경외과학회
  4. Kathleen R. Fink, "Imaging of brain metastases", Surg Neurol Int, 4(4), pp.209~219 (2013)
  5. Marc C. Mabray, "Modern Brain Tumor Imaging", Brain Tumor Research and Treatment, 3(1), pp.8~23 (2015), 대한뇌종양학회
  6. Lee WY, "Transcranial sonography in parkinsons’s disease and parkinsonism", Journal of Movement Disorders, 1(1), pp.6~12 (2008)
  7. Lee WH, "Clinical application of 18F-FDG PET in parkinson’s disease", Nucl Med Mol Imaging, 42, pp.177~180 (2008)
  8. 이상규, "우리나라 고가 의료장비 현황과 정책대안: 정책의 수직적, 수평적 동기화", 대한의사협회지, 55(10), pp.950~958 (2012), 대한의사협회[DOI]
  9. Pasha Razifar, "Noise correlation in PET, CT, SPECT and PET", CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM, 2005, pp.5(5), 148~152
  10. Marcus Soderberg, "The effect of different adaptation strengths on image quality and radiation dose using siemens care dose 4D", Radiation Protection Dosimetry, 139(1-3), pp.173~179 (2010)
  11. W Mazrani, "The radiation burden of radiological investigations", Arch Dis Child, 92(12), pp.1127~1131 (2007)
  12. Vigh Teichmann I, "The system of cerebrospinal fluid-contacting neurons", Arch Histol Jpn, 46(4), pp.427~468 (1983)
  13. Balajiranganathan Anupreethi, Shivaramu, "Effective atomic numbers for photon energy absorption and energy dependence of some thermoluminescent dosimetric materials", IARP, 39(2), pp.62~67 (2016)
  14. Hidehiro Iida, "Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour", Ann Nucl Med, 27(1), pp.25~36 (2013)
  15. Abraham T, "Evolution of brain imaging instrumentation", Semin Nucl Med, 41(3), pp.202~219 (2011)
  16. Qinan Bao, "Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method", Med Phys, 31(11), pp.6070~6083 (2010)
  17. Daube-Witherspoon ME, "PET performance measurements using the NEMA NU 2-2201 standard", J Nucl Med, 43(10), pp.1398~1409 (2002)
  18. Charles C. Watson, "NEMA NU 2 performance tests for scanners with intrinsic radioactivity", J Nucl Med, 45(5), pp.822~826 (2004)
  19. The measurement, reporting and management of radiation dose in CT, "AAPM", American Association of Physicists in Medicine, ~, pp.AAPM Report 96 (2007)
  20. Ting Xia, "Ultra-low dose CT attenuation correction for PET", CT, 2012, pp.57(2), 309~328
  21. Xia T, "Dual energy CT for attenuation correction with PET", CT, 2014, pp.41(1), 012501~
  22. Joshi A, "Reducing between scanner differences in multi-center PET studies", NeuroImage, 46(1), pp.154~159 (2009)
  23. Calvini P, "The basal ganglia matching tools package for striatal uptake semi-quantification : description and validation", Eur J Nucl Med Mol Imaging, 34(8), pp.1240~1253 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (15건)