Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

Abstract

Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

참고문헌 (18)

  1. Knoll GF, "Radiation detection and measurement" (2010), John Wiley & Sons
  2. Ahmed SN, "Physics and engineering of radiation detection" (2007), Academic Press
  3. Sinclair TR, "Advances in agronomy, 65", pp.215~265 (1999), Academic Press
  4. Yoshimuta T, "Inventors; Shimadzu Corp, assignee. Radiation detector and method of manufacturing the same", United States patent US 9,985,150, ~ (2018)
  5. Lindell B, "A history of radiation protection", Radiation Protection Dosimetry, 68(1-2), pp.83~95 (1996)
  6. Wagenaar DJ, "Advantages of semiconductor CZT for medical imaging", Penetrating Radiation Systems and Applications VIII. International Society for Optics and Photonics, 6707, pp.67070I~ (2007)
  7. Simulation and performance test technology development for semiconductor radiation detection instrument fabrication, "Kim JK", Korea Atomic Energy Research Institute, ~ (2010)
  8. Iniewski K, "CZT detector technology for medical imaging", Journal of Instrumentation, 9(11), pp.C11001~ (2014)
  9. Zha G, "The development of CZT semiconductor X-ray and γ-ray detectors", Wuli, 42(12), pp.862~869 (2013)
  10. Park SY, "Development and utilization of portable nuclide-analysis system for simultaneous measurements of neutrons and gamma rays", The Journal of the Korean Radioactive Waste Society, 18(1), pp.335~336 (2020)
  11. Development of charge sensitive preamplifier and readout integrate circuit board for high resolution detector using ASIC process, "Jeon JY", Korea Atomic Energy Research Institute, ~ (2010)
  12. Analysis of study trend of growth and characterization of CdZnTe single crystal, "Lee KH", Korea Atomic Energy Research Institute, ~ (2011)
  13. Streicher M, "Fast neutron detection using pixelated CdZnTe spectrometers", IEEE Transactions on Nuclear Science, 64(7), pp.1920~1926 (2017)
  14. Attix FH, "Introduction to radiological physics and radiation dosimetry" (2008), John Wiley & Sons
  15. Andreo P, "Fundamentals of ionizing radiation dosimetry" (2017), John Wiley & Sons
  16. Schulte RL, "Inventors; Northrop Grumman Corp, assignee. Directional thermal neutron detector", United States patent US 5,659,177, 177~ (1997)
  17. 배상일, "몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가", 방사선기술과학, 43(5), pp.389~395 (2020), 대한방사선과학회
  18. 이동연, "몬테칼로시뮬레이션을 이용한 선형가속기 차폐벽에 대한 중성자 특성 평가", 방사선기술과학, 39(1), pp.89~97 (2016), 대한방사선과학회[DOI]

관련 논문AI추천

CZT 반도체 검출기를 활용한 중성자 및 감마선 측정과 분석 기술에 관한 연구곽상수, 김희경, 이재근, 진동식, 홍용호대한방사선과학회 · Journal of Radiological Science and Technology2022 · 제45권 제1호Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-rayDong-Sik Jin, Hui-Gyeong Kim, Jae-Geun Lee, Sang-Soo Kwak, Yong-Ho Hong, Young-Suk Jung한국분석과학회 · 분석과학2022 · 제35권 제2호사용후핵연료 연소도 측정을 위한 감마선 검출기의 분광특성 연구김태영, 박혜민, 송양수, 이운장, 함철민(사)한국방사선산업학회 · 방사선산업학회지2023 · 제17권 제1호습식 저장시설 내 사용후핵연료 연소도 측정을 위한 감마선/중성자 검출기 개발김태영, 박혜민, 송양수, 이운장, 이인호, 장대헌, 함철민(사)한국방사선산업학회 · 방사선산업학회지2024 · 제18권 제3호Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film김기현, 김용훈, 박범준, 박지수, 변장원, 서지원, 신기창, 이경원, 이원호한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제3호현장형 사용후핵연료 연소도 측정 시스템 개발을 위한 예비실험김태영, 박혜민, 송양수, 이운장, 장대헌, 함철민(사)한국방사선산업학회 · 방사선산업학회지2025 · 제19권 제1호

이 간행물의 다른 논문 (11건)