본문 바로가기
KERD
논문KCI 등재

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy・cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

Abstract

The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy・cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

참고문헌 (25)

  1. Kim MS, "The carotid artery ultrasonogrphy's usefulness for the prediction of ischemic brain vessel disease", Korean Society of Medical Sonographers, 3(1), pp.15~ (2012)
  2. Hirai T, "Prospective evaluation of suspected stenooccluive disease of the intracranial artery: combined MR angiography and CT angiography compared with digital subtraction angiography", AJNRAm J Neuroradiol, 23(1), pp.93~ (2002)
  3. 이정민, "족부 혈관의 평가: 3차원 Gadolinium 조영 증강 자기공명 혈관조영술과 디지털 감산 혈관조영술의 비교", 대한영상의학회지, 47(1), pp.21~26 (2002), 대한영상의학회
  4. 이정근, "MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구", 방사선기술과학, 36(2), pp.131~139 (2013), 대한방사선과학회
  5. Goldenberg G, "Angiographic findings in relation to clinical course and results of computed tomography in cerebrovascular disease", EUR Neurol, 22, pp.124~ (1983)
  6. Rubin GD, "Multi-detector row CT angiography of lower extremity arterial inflow and runoff: initial experience", Radiology, 221(1), pp.146~ (2001)
  7. Schramm P, "Comparison of perfusion computed tomography and computed tomography angiography source images with perfusion-weighted imaging and diffusion-weighted imaging in patients with acute stroke of less than 6 hours’duration", Stroke, 35(7), pp.1652~ (2004)
  8. Lin CH, "Dual energy computed tomography angiography for the rapid diagnosis of reversible cerebral vasoconstriction syndromes:report of a case", Acta Neurol Taiwan, 22(1), pp.36~ (2013)
  9. Lee W, "Technical aspect of coronary CT angiography: Imaging tips and safety issues", J Korean Med Assoc, 50(2), pp.104~ (2007)
  10. Kirchner J, "Optimized enhancement in helical CT:experiences with a real-time bolus tracking system in 628patients", Clin Radiol, 55(5), pp.368~ (2000)
  11. Brenner DJ, "Computed tomography an increasing source of radiation exposure", N Engl J Med, 357(22), pp.2277~ (2007)
  12. Hany TF, "Optimization of contrast timing for breath-hold three dimentional MR angiography", J Magn Reson Imaging, 7(3), pp.551~ (1997)
  13. Strouse PJ, "Effect of the rate of gadopentetate dimeglumine administration on abdominal vascular and soft-tissue MR imaging enhancement patterns", Radiology, 201(3), pp.809~ (1996)
  14. Seo MR, "Usefulness of test bolus injection on contrast-enhanced 3D FISP abdominal MR angiography", pp.1998
  15. Bae KT, "Test-bolus versus bolus-tracking techniques for CT angiographic timing", Radiology, 236(1), pp.369~ (2005)
  16. 박선미, "TCD를 이용한 정상군과 고지혈증군의 혈류측정에 관한 비교연구", 동의생리병리학회지, 23(6), pp.1513~1520 (2009), 한의병리학회
  17. Paksoy Y, "Retrograde flow in the left inferior petrosal sinus and blood steal of the cavernous sinus associated with central vein stenosis: MR angiographic f indings", AJNR Am J Neuroradiol, 24(7), pp.1364~ (2003)
  18. You SY, "Effects of right-versus left-arm injections of contrast material on computed tomography of the head and neck", J Comput Assist Tomogr, 31(5), pp.677~ (2007)
  19. Yakup Y, "Endovascular management of iatrogenic renal artery aneurysm and arteriovenous fistula", Saudi J Kidney Dis Transpl, 23(4), pp.838~ (2012)
  20. Dinkel HP, "Optimizing liver contrast in helical liver CT: value of a real-time bolus-triggering technique", Eur Radiol, 8(9), pp.1608~ (1998)
  21. Bae KT, "Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate-pharmacokinetic analysis and experimental porcine model", Radiology, 206(2), pp.455~ (1998)
  22. Kim JK, "Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography", Radiology, 206(1), pp.283~ (1998)
  23. Cai Z, "Bolus characteristics based on Magnetic Resonance Angiography", Biomed Eng Online, 5, pp.53~ (2006)
  24. Brenner D, "Estimated risks of radiation-induced fatal cancer from pediatric CT", AJR Am J Roentgenol, 176(2), pp.289~ (2001)
  25. Pierce DA, "Radiation-related cancer risks at low doses among atomic bomb survivors", Radiat Res, 154(2), pp.178~ (2000)