본문 바로가기
KERD
논문KCI 등재

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정

Scattering Measurement of Syringe Shield Used in PET/CT

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

Abstract

PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

참고문헌 (21)

  1. 박준철, "핵의학 종사자에서 손 부위의 외부 피폭선량 연구", 방사선기술과학, 35(2), pp.141~149 (2012), 대한방사선과학회[DOI]
  2. ICRP, "General principle of monitoring for radiological protection. ICRP Publication 35" (1982), pergamon Press
  3. 한동현, "GEANT4를 이용한 99mTc 주입시 손가락 선량계산", 방사선방어학회지, 33(1), pp.41~46 (2008), 테스트학회
  4. Warren-Forward H, "A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation", Radiation Protection Dosimetry, 124(2), pp.89~96 (2007)
  5. Deb P, "An evaluation of the shielding effectiveness of lead aprons used in clinics for protection against ionising radiation from novel radioisotopes", Radiation Protection Dosimetry, 165, pp.443~447 (2015)
  6. Ianniello A, "McParland: Nuclear medicine radiation dosimetry" (2011), Springer
  7. Tissue substitutes in radiation dosimetry and measurement, "Goldstone KE", International Commission on Radiation Units and Measurements, ~, pp.ICRU Report 44 (1990)
  8. Stopping powers and ranges for electrons and positrons, "ICRU", International Commission on Radiation Units and Measurements, ~, pp.ICRU Report 37 (1984)
  9. Smith H, "Conversion coefficients for use in radiological protection against external radiation. ICRP publication 74" (1997), International Commission on Radiological Protection, Pergamon Press
  10. Menzel HG, "ICRP Publication 110. Realistic reference phantoms: An ICRP", ICRU joint effort. A report of adult reference computational phantoms, 2009, pp.39(2), 1~
  11. Valentin J, "Basic anatomical and physiological data for use in radiological protection : Reference values : ICRP Publication 89", Annals of the ICRP, 32, pp.1~277 (2002)
  12. Compendium of material composition data for radiation transport modeling, "Williams RG", Pacific Northwest National Lab.(PNNL), ~, pp.No. PNNL-15870 (2006)
  13. -FDG in PET, "CT and cyclotron center using thermoluminescent dosimetry", Journal of Biomedical Physics & Engineering, 7(1), pp.1~ (2017)
  14. 장동근, "의료 방사선사용에 따른 납과 텅스텐의 차폐효과 분석", 한국방사선학회논문지, 12(2), pp.173~178 (2018), 한국방사선학회[DOI]
  15. Aminian M, "Comparison of the protection performance in a composite shield and a lead standard shield in terms of biological effects in nuclear medicine", Iranian Journal of Nuclear Medicine, 25(2), pp.129~135 (2017)
  16. 장동근, "몬테카를로 모의 모사를 이용한 핵의학과 방사선작업종사자의 손에 대한 피폭선량 분석", 방사선기술과학, 38(4), pp.477~482 (2015), 대한방사선과학회[DOI]
  17. 장동근, "PET", CT 검사에서 납 차폐체 사용에 따른 에너지 흡수 분포에 관한 모의실험, 2015, pp.9(7), 459~465[DOI]
  18. He X, "Answers to if the lead aprons are really helpful in nuclear medicine from the perspective of spectroscopy", Radiation Protection Dosimetry, 174(4), pp.558~564 (2017)
  19. Mariotti F, "Extremity dosimetry problems during the handling of radionuclides syringes in nuclear medicine : A Monte Carlo radiation transport simplified approach", Radiation Measurements, 46(4), pp.430~435 (2011)
  20. Jang DG, "Therapeutic radionuclides : Beta radiation range", Journal of Instrumentation, 15(08), pp.T08002~ (2020)
  21. 심대무, "척추 주사요법을 시행한 정형외과 의사수부에 발생한 방사선 유발 피부괴사", 대한정형외과학회지, 49(3), pp.250~254 (2014), 대한정형외과학회

관련 논문AI추천

이 간행물의 다른 논문 (10건)