초음파 검사용 젤과 젤 용기의 세균증식 원인

Causes of Bacterial Growth in Gels and Gel Containers Used for Ultrasonography

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner's hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner's hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner's hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.

Abstract

This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner's hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner's hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner's hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.

참고문헌 (20)

  1. 유진홍, "국내 최신 감염관리 동향과 전망", 의료관련감염관리, 21(1), pp.1~8 (2016), 대한의료관련감염관리학회
  2. Kim EJ, "Infection control and prevention in Healthcare facilities(4)" (2011), Hanmimedical Publishing Printing
  3. Lee MK, "Intensive Care Unit Nurses' Knowledge, Recognition, and Performance of Hospital Infection Control", ~ (2012)
  4. Korean Socity for Healthcare-associated Infection Control and Prevention, "Infection control and Prevention in Healthcare Facilities" (2017), Hanmimedical Publishing Printing
  5. Trick WE, "Impact of ring wearing on hand contamination and comparison of hand hygiene agents in a hospital", Clinical Infectious Diseases, 36(11), pp.1383~1390 (2003)
  6. 정선영, "국내 의료기관의 소독과 멸균 관리 실태", 기본간호학회지, 21(4), pp.392~402 (2014), 기본간호학회[DOI]
  7. Sim HS, "Diagnostic ultrasound physics" (2011), Hanmimedical Publishing Printing
  8. Sim HS, "Ultrasonography" (2012), Hanmimedical Publishing Printing
  9. Sim HS, "Ultrasonography Anatomy&Scan Technique", ~ (2009)
  10. "Guideline for disinfection and sterilization in healthcare facilities" (2014)[URL]
  11. "Ultrasonic gel, safety management blind spot" (2014)[URL]
  12. Baron EJ, "Specimen collection, transport, and processing: Bacteriology" (2015), American Society for Microbiology
  13. Korean Socity for Laboratory Medicine, "Laboratory Medicine(5)" (2014), E-PUBIC Publishing Printing
  14. Korean Socity for Healthcare-associated Infection Control and Prevention, "Infection control and Prevention in Healthcare Facilities" (2017), Hanmimedical Publishing Printing
  15. Korean Socity for Healthcare-associated Infection Control and Prevention, "Infection control and Prevention in Healthcare Facilities" (2017), Hanmimedical Publishing Printing
  16. Hwang SW, "Opportunistic infections and intra-infested infections", Busan Social Paper, 21(3), pp.3~5 (1985)
  17. 최성호, "Staphylococcus lugdunensis에 의한 감염성 심내막염 1예", Infection and Chemotherapy, 38(5), pp.277~281 (2006), 대한감염학회
  18. 이희진, "일개 상급종합병원에 근무하는 간병인의 의료 관련감염 관리 수행도 및 손의 미생물 오염도에 영향을 미치는 요인", 근관절건강학회지, 26(3), pp.241~250 (2019), 대한근관절건강학회[DOI]
  19. "WHO Guidelines on Hand Hygiene in Health Care:First Global Patient Safety Challenge Clean Care Is Safer Care" (2009)[URL]
  20. Boyce JM, "Guideline for hand hygiene in health-care settings. recommendations of the healthcare infection control practices advisory committee and the hicpac", shea, idsa hand hygiene task force, pp.American Journal of Infection Control, 2002[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)