본문 바로가기
KERD
논문KCI 등재

Bacterial Contamination of Surfaces in an Ultrasound Room

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The ongoing coronavirus disease 2019 (COVID-19) pandemic has highlighted the importance of hospital hygiene and infection control in hospital settings. To raise hygiene awareness among ultrasound technicians, we evaluated the hygiene status of an ultrasound room, in comparison with that of objects used in daily life. Using the swab method, the following surfaces were examined: eight surfaces in the ultrasound room including the ultrasound probes (convex, linear, sector, 3D), ultrasound track ball, ultrasound keyboard, ultrasound gel (sealed and in use) and pillow as well as four surfaces of everyday objects including subway handles, common computer keyboards, common computer mouse, and cell phones. The streak plate technique was used for inoculation into media, which was observed for the formation of bacterial colonies following incubation for 24 h. Six bacterial strains were detected from objects used in the ultrasound room, including methicillin-resistant Staphylococcus aureus. Four strains of bacteria were detected on surfaces of everyday objects. The equipment and accessories used in an ultrasound room can act as vehicles for infecting patients. Establishment of standardized hygiene protocols and periodic training of the staff are recommended to avoid cross-infection.

Abstract

The ongoing coronavirus disease 2019 (COVID-19) pandemic has highlighted the importance of hospital hygiene and infection control in hospital settings. To raise hygiene awareness among ultrasound technicians, we evaluated the hygiene status of an ultrasound room, in comparison with that of objects used in daily life. Using the swab method, the following surfaces were examined: eight surfaces in the ultrasound room including the ultrasound probes (convex, linear, sector, 3D), ultrasound track ball, ultrasound keyboard, ultrasound gel (sealed and in use) and pillow as well as four surfaces of everyday objects including subway handles, common computer keyboards, common computer mouse, and cell phones. The streak plate technique was used for inoculation into media, which was observed for the formation of bacterial colonies following incubation for 24 h. Six bacterial strains were detected from objects used in the ultrasound room, including methicillin-resistant Staphylococcus aureus. Four strains of bacteria were detected on surfaces of everyday objects. The equipment and accessories used in an ultrasound room can act as vehicles for infecting patients. Establishment of standardized hygiene protocols and periodic training of the staff are recommended to avoid cross-infection.

참고문헌 (24)

  1. Sartoretti T, "Bacterial contamination of ultrasound probes in different radiological institutions before and after specific hygiene training:do we have a general hygienical problem?", European Radiology, 27(10), pp.4181~4187 (2017)
  2. Paintsil E, "Hepatitis C virus maintains infectivity for weeks after drying on inanimate surfaces at room temperature : Implications for risks of transmission", The Journal of Infectious Diseases, 209(8), pp.1205~1211 (2014)
  3. 김아영, "초음파 검사용 젤과 젤 용기의 세균증식 원인", 방사선기술과학, 43(5), pp.359~365 (2020), 대한방사선과학회
  4. Rutala WA, "APIC guideline for selection and use of disinfectants", American Journal of Infection Control, 18(2), pp.99~117 (1990)
  5. "Guideline for disinfection and sterilization in healthcare facilities" (2008)[URL]
  6. 윤준, "의료용 초음파 프로브 상제균의 효과적인소독법에 관한 연구", 한국산학기술학회논문지, 19(1), pp.346~354 (2018), 한국산학기술학회[DOI]
  7. report, data summary of 45 countries for 2012-2017 : Device-associated module, "American Journal of Infection Control", 2020, 423~432
  8. McBryde E, "An investigation of contact transmission of methicillin-resistant Staphylococcus aureus", Journal of Hospital Infection, 58(2), pp.104~108 (2004)
  9. Eckstein BC, "Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods", BMC Infectious Diseases, 7(1), pp.1~6 (2007)
  10. Guerrero DM, "Beyond the Hawthorne effect : Reduction of Clostridium difficile environmental contamination through active intervention to improve cleaning practices", Infection Control &Hospital Epidemiology, 34(5), pp.524~526 (2013)
  11. Nyhsen CM, "Infection prevention and control in ultrasound-best practice recommendations from the European Society of Radiology Ultrasound Working Group", Insights into Imaging, 8(6), pp.523~535 (2017)
  12. Liu R, "Policy statement guideline for ultrasound transducer cleaning and disinfection", Annals of Emergency Medicine, 72, pp.1016~ (2018)
  13. Rutala WA, "Disinfection and sterilization:an overview", American Journal of Infection Control, 41(5), pp.S2~S5 (2013)
  14. 하명진, "초음파 탐촉자의 위생관리에 관한 연구", 방사선기술과학, 43(2), pp.87~96 (2020), 대한방사선과학회
  15. Sweet D, "An improved method to recover saliva from human skin : The double swab technique", Journal of Forensic Science, 42(2), pp.320~322 (1997)
  16. Harley J, "Laboratory exercises in microbiology", pp.49~53 (1990), Wm. C. Brown Publishers
  17. Cappuccino JG, "Microbiology: A laboratory manual", pp.2005, Benjamin
  18. Tarzmani MK, "Role of ultrasound probes in transmission of hospital infections", Caspian Journal of Internal Medicine, 1(4), pp.134~136 (2010)
  19. Chu K, "Bacterial contamination of ultrasound probes at a tertiary referral university medical center", American Journal of Roentgenology, 203(5), pp.928~932 (2014)
  20. Yue J, "Linezolid versus vancomycin for skin and soft tissue infections", Evidence‐Based Child Health : A Cochrane Review Journal, 9(1), pp.103~166 (2014)
  21. Maselli DJ, "Inhaled antibiotic therapy in chronic respiratory diseases", International Journal of Molecular Sciences, 18(5), pp.1062~ (2017)
  22. An R, "Moraxella osloensis gene expression in the slug host Deroceras reticulatum", BMC Microbiology, 8(1), pp.1~11 (2008)
  23. infections in surgical wounds, "Cochrane Database of Systematic Reviews", 2013, CD010427~
  24. Schenck LP, "Composition and immunological significance of the upper respiratory tract microbiota", FEBS Letters, 590(21), pp.3705~3720 (2016)

이 간행물의 다른 논문 (12건)