본문 바로가기
KERD
논문KCI 등재

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가

Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

Abstract

This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

참고문헌 (25)

  1. Nag S, "High dose rate brachytherapy : Its clinical applications and treatment guidelines", Technol Cancer Res Treat, 3(3), pp.269~287 (2004)
  2. Kapp KS, "Prognostic factors in patients with carcinoma of the uterine cervix treated with external beam irradiation and IR-192high-dose-rate brachytherapy", Int J Radiat Oncol Biol Phys, 42(3), pp.531~540 (1998)
  3. Schmidt-Ullrich R, "Interstitial Ir-192 implants of the oral cavity : The planning and construction of volume implants", Int J Radiat Oncol Biol Phys, 20(5), pp.1079~1085 (1991)
  4. Escobar-Sacristán JA, "Endobronchial brachytherapy in the treatment of malignant lung tumours", European Respiratory Journal, 24, pp.348~352 (2004)
  5. Foppiano F, "A general-purpose dosimetric system for brachytherapy" (2005), American Nuclear Society
  6. 강상구, "몬테카를로 방법에 의한 6MV 선형가속기의 광자 흡수선량 분포 평가에 관한 연구", 방사선기술과학, 34(1), pp.43~50 (2011), 대한방사선과학회
  7. Xu XG, "An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: A review of the fifty-year history", Phys Med Biol, 59(18), pp.R233~R302 (2014)
  8. Borg J, "Monte Carlo calculations of photon spectra in air from 192Ir sources", NRC Institute for National Measurement Standards;National Research Council Canada, ~ (1999)
  9. Chu SYF, "WWW Table of Radioactive Isotopes", Lawrence Berkeley National Laboratory; Version 2, ~ (1999)
  10. Schoenfeld AA, "Water equivalent phantom materials for 192Ir brachytherapy", Phys Med Biol, 60(24), pp.9403~9420 (2015)
  11. On the neutron transparency of various materials proposed for the AIDA enclosure, "Reillo E", CINEMAT, ~ (2008)
  12. Gronostajski JZ, "Formability, damage and corrosion resistance of coated steel sheets", Materials Processing Defects, 43, pp.203~218 (1995)
  13. "Sheet Metal Density Table (Common Materials)"[URL]
  14. Andreo P, "Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water", International Atomic Energy Agency Iaea; V.12, ~ (2006)
  15. 정동혁, "원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구", 의학물리, 20(1), pp.30~36 (2009), 한국의학물리학회
  16. Photon, electron, proton and neutron interaction data for body tissues, International Commission on Radiological Units and Measurements, "ICRU", ~, pp.ICRU Report 46 (1992)
  17. Karaiskos P, "Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source", Med Phys, 25(10), pp.1975~1984 (1998)
  18. Mowlavi AA, "Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom", International Journal of Radiation Research, 6(1), pp.37~42 (2008)
  19. Kutcher GJ, "Comprehensive QA for radiation oncology : Report of AAPM Radiation Therapy Committee Task Group 40", Med Phys, 21(4), pp.581~618 (1994)
  20. Khan FM, "Khan's The Physics of Radiation Therapy" (2014), Lippincott Williams & Wilkins, A Wolters Kluwer Business
  21. Thomadsen BR, "Anniversary paper : Past and current issues, and trends in brachytherapy physics", Med Phys, 35(10), pp.4708~4723 (2008)
  22. Metcalfe P, "The physics of radiotherapy X-rays from linear accelerators", pp.395~417 (1997), Medical Physics Publishing
  23. 강정구, "Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산", 의학물리, 26(1), pp.36~41 (2015), 한국의학물리학회[DOI]
  24. 이상호, "유방촬영에서 Geant4 시뮬레이션을 이용한 유방조직내 흡수선량에 관한 연구", 방사선기술과학, 35(4), pp.345~352 (2012), 대한방사선과학회
  25. ChatGipapas C, "Clinical evaluation of pediatric brachytherapy applications, using MC simulations", Master, pp.2016

관련 논문AI추천

이 간행물의 다른 논문 (11건)