201-Tl의 생산과정에서 발생한 방사성 폐기물의 제염 효율 평가
Evaluation of the Decontamination Efficiency of Radioactive Wastes Generated during the Production of 201Tl
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study was conducted for the purpose of efficient radioactive waste disposal and management. Experiment was evaluated the decontamination efficiencies of the four types decontamination materials(Water, Alcohol, Decontamination Water, Decontamination Gel) with radioactive wastes generated during radio-pharmaceutical production process at Korea Institute Radiological and Medical Sciences(KIRAMS). The radioactive waste sample used in experiment is a lead plate of the fume hood that was disposed in April, 2019. In the experimental method, radioactive waste was measured before and after decontamination using a HPGe semiconductor detector and Gamma survey meter. The measured values before and after decontamination were evaluated for decontamination efficiency as a percentage. As a result, it was confirmed that a lot of specific activity and surface dose rate was removed from the radioactive wastes. In particular, when decontamination water was used, most of the radioactivity of radioactive wastes was removed. Considering these results, if decontamination water is used in decontamination of radioactive waste, decontamination efficiency equivalent to the disposition criteria can be expected with just one decontamination treatment. In addition, in the case of water and alcohol, only on decontamination was effective in approximately 75% and 95%. Otherwise, when decontamination gel was used, it was confirmed that the largest deviation occurred among all experimental results.
Abstract
This study was conducted for the purpose of efficient radioactive waste disposal and management. Experiment was evaluated the decontamination efficiencies of the four types decontamination materials(Water, Alcohol, Decontamination Water, Decontamination Gel) with radioactive wastes generated during radio-pharmaceutical production process at Korea Institute Radiological and Medical Sciences(KIRAMS). The radioactive waste sample used in experiment is a lead plate of the fume hood that was disposed in April, 2019. In the experimental method, radioactive waste was measured before and after decontamination using a HPGe semiconductor detector and Gamma survey meter. The measured values before and after decontamination were evaluated for decontamination efficiency as a percentage. As a result, it was confirmed that a lot of specific activity and surface dose rate was removed from the radioactive wastes. In particular, when decontamination water was used, most of the radioactivity of radioactive wastes was removed. Considering these results, if decontamination water is used in decontamination of radioactive waste, decontamination efficiency equivalent to the disposition criteria can be expected with just one decontamination treatment. In addition, in the case of water and alcohol, only on decontamination was effective in approximately 75% and 95%. Otherwise, when decontamination gel was used, it was confirmed that the largest deviation occurred among all experimental results.
참고문헌 (17)
- Vértes A, "Handbook of Nuclear Chemistry", pp.1904~1933 (2011), Springer
- 황선용, "IBA 사이클로트론 표적집합체에서의 잔류 방사화 분석 및 선량률 평가", 방사선기술과학, 39(4), pp.643~649 (2016), 대한방사선과학회[DOI]
- IAEA, "Application of the Concepts of Exclusion Exemption and Clearance: SAFETY GUIDE No. RS-G-1.7", IAEA, ~ (2004)
- IAEA, "Classification of radioactive waste: General Safety Guide GSG-1", IAEA, ~ (2009)
- "Korea Act. Nuclear Safety Act(Act No. 16575, 27. Aug, 2019., Partial Amendment)", ~ (2019)
- "Korea Act. Nuclear Safety and Security Commission, Enforcement decree of the nuclear safety Act(Presidential Decree No. 29521, Feb. 8, 2019)", ~ (2019)
- 김창범, "의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가", 의학물리, 25(1), pp.8~14 (2014), 한국의학물리학회[DOI]
- Ruhman N, "The effectiveness of decontamination products in the nuclear medicine department", J Nucl Med Technol, 38(4), pp.191~194 (2010)
- Akchata S, "Influence of Decontaminating Agents and Swipe Materials on Laboratory Simulated Working Surfaces Wet Spilled with Sodium Pertechnetate", Indian J Nucl Med, 32(3), pp.173~176 (2017)
- Leonardi NM, "Radioactivity decontamination of materials commonly used as surfaces in general-purpose radioisotope laboratories", J Nucl Med Technol, 42(4), pp.292~295 (2014)
- VanHorne-Sealy JD, "Evaluating the Efficiency of Decon Gel 1101 for Removal of Cs-137, Co-60, and Eu-154 On Common Commercial Construction Materials", master’s, pp.2008
- Gurau D, "The use of chemical gel for decontamination during decommissioning of nuclear facilities", Radiation Physics and Chemistry, 106, pp.371~375 (2015)
- 김창범, "의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정", 방사선기술과학, 40(4), pp.633~638 (2017), 대한방사선과학회[DOI]
- Heo H., "Application of the Surfactant-Enhanced soil washing to crude oil contamination soils in Kuwait", master’s, pp.2015
- Rosen MJ, "Surfactants and interfacial phenomena", pp.1~34 (2012), Wiley
- Pinho SP, "Solubility of NaCl, NaBr and KCl in Water, Methanol, Ethanol, and their Mixed Solvents", J Chemical and Engineering Data, 50(1), pp.29~32 (2005)
- Plutonium Decontamination Using CBI DecongelTM 1101 in Highly Contaminated and Unique Areas at LLNL, "Sutton M", LLNL, ~, pp.LLNL-TR-404723 (2008)