초록

Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically ad- just the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement de- vice was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

Abstract

Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically ad- just the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement de- vice was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

참고문헌 (16)

  1. Managing low radioactivity material from the decommissioning of nuclear facilities, "International Atomic Energy Agency", IAEA, ~, pp.IAEA Technical Report Series No. 462
  2. "Regulations on the calculation standards of radioactive waste management costs and spent nuclear fuel management charges, etc. MOTIE Notification No. 2022-11"[URL]
  3. "Cyclotrons used for radionuclide production"[URL]
  4. Woo RN, "A study on the adoption of cyclotron decommissioning plan criteria by the analysis of domestic relocation and abroad dismantling practices", Journal of Radiation Protection, 38(2), pp.91~99 (2013)[DOI]
  5. Hwang SY, "Evaluation of residual radioactivity and dose rate of a target assembly in an IBA cyclotron", Radiological Science and Technology, 39(4), pp.643~649 (2016)[DOI]
  6. Lee DY, "Characterization of the neutron for linear accelerator shielding wall using a monte carlo simulation", Radiological Science and Technology, 39(1), pp.89~97 (2016)[DOI]
  7. Lee DY, "A study on the calculation of the shielding wall thickness in Medical Linear Accelerator", Radiological Science and Technology, 40(2), pp.281~287 (2017)[DOI]
  8. Kim YS, "Large-area compton camera for high-speed and three-dimensional imaging", IEEE Transactions on Nuclear Science, 65(11), pp.2817~2822 (2018)[DOI]
  9. Lee JY, "Development of simultaneous multi-channel data acquisition system for Large-Area Compton Camera(LACC)", Nuclear Engineering and Technology, 55, pp.3822~3830 (2023)[DOI]
  10. Lee HS, "Design and performance prediction of Large-area Hybrid Gamma Imaging System(LAHGIS)for localization of lowlevel radioactive material", Nuclear Engineering and Technology, 53(4), pp.1259~1265 (2021)[DOI]
  11. Lee HS, "Development and performance evaluation of large-area hybrid gamma imager", Nuclear Engineering and Technology, 53(8), pp.2640~2645 (2021)[DOI]
  12. Choi SH, "Real-time contextual data-updated 3-D radiation image reconstruction for large-area hybrid gamma imager", Transactions of the Korean Nuclear Society Spring Meeting (2022)
  13. Vetter K, "Gamma-ray imaging for nuclear security and safety : Towards 3-D gamma-ray vision", Nuclear Instruments and Methods, Physics Research Section A : Accelerators, Spectrometers, Detectors, and Associated Equipment, 878(11), pp.159~168 (2018)[DOI]
  14. Kim JH, "Development of CZT-based portable gamma imaging system for Korea customs service", The Eleventh international Symposium on Radiation Safety and Detection Technology, pp.333~334 (2023)
  15. Kim JH, "Development of hybrid shielding system for largearea Compton camera : A Monte Carlo study", Nuclear Engineering and Technology, 52, pp.2361~2369 (2020)[DOI]
  16. Ajay K, "Natural activities of 238U, 232Th and 40K in some Indian building materials", Radiation Measurements, 36, pp.465~469 (2003)[DOI]