경골 천정(pilon) 골절의 최신 치료
Current Treatment of Tibial Pilon Fractures
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured,fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location,rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started.. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point,the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.
Abstract
Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured,fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location,rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started.. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point,the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.
참고문헌 (19)
- Ovadia DN, "Fractures of the tibial plafond", J Bone Joint Surg Am, 68, pp.543~551 (1986)
- Mast JW, "A reproducible approach to the internal fixation of adult ankle fractures: rationale, technique, and early results", Orthop Clin North Am, 11, pp.661~679 (1980)
- "Unfallchirurg", 1994, 39~46
- Bone LB, "Fractures of the tibial plafond. The pilon fracture", Orthop Clin North Am, 18, pp.95~104 (1987)
- Barei DP, "Fractures of the tibial plafond", Foot Ankle Clin, 13, pp.571~591 (2008)
- Rüedi TP, "The operative treatment of intra- articular fractures of the lower end of the tibia", Clin Orthop Relat Res, 138, pp.105~110 (1979)
- Teeny SM, "Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications", Clin Orthop Relat Res, 292, pp.108~117 (1993)
- Baumgaertel F, "Fracture healing in biological plate osteosynthesis", Injury, 29 (1998)
- Helfet DL, "Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia", Instr Course Lect, 53, pp.471~475 (2004)
- Coonrad RW, "Fracture-dislocations of the ankle joint with impaction injury of the lateral weight-bearing surface of the tibia", J Bone Joint Surg Am, 52, pp.1337~1344 (1970)
- Bedi A, "Surgical treatment of nonarticular distal tibia fractures", J Am Acad Orthop Surg, 14, pp.406~416 (2006)
- Helfet DL, "Minimally invasive plate osteosynthesis of distal fractures of the tibia", Injury, 28 (1997)
- 이근배, "원위 경골 골절: 금속판 고정술", 대한골절학회지, 22(4), pp.306~313 (2009), 대한골절학회
- Collinge C, "Treatment of complex tibial periarticular fractures using percutaneous techniques", Clin Orthop Relat Res, 375, pp.69~77 (2000)
- Arens S, "Susceptibility to local infection in biological internal fixation. Experimental study of open vs minimally invasive plate osteosynthesis in rabbits", Arch Orthop Trauma Surg, 119, pp.82~85 (1999)
- Foux A, "Improved fracture healing with less rigid plates. A biomechanical study in dogs", Clin Orthop Relat Res, 339, pp.232~245 (1997)
- Bone L, "External fixation of severely comminuted and open tibial pilon fractures", Clin Orthop Relat Res, 292, pp.101~107 (1993)
- Blauth M, "Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques", J Orthop Trauma, 15, pp.153~160 (2001)
- Gehr J, "New concepts in the treatment of ankle joint fractures. The IP-XS (XSL) and IP-XXS (XXSL) nail in the treatment of ankle joint fractures", Arch Orthop Trauma Surg, 124, pp.96~103 (2004)