본문 바로가기
KERD
논문KCI 등재

원위 경골 골절에서 전외측 잠김 금속판을 사용한 전외측 최소 침습적 금속판 고정술

Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: Anterolateral minimally invasive plate osteosynthesis (MIPO) was performed to treat patients with distal tibial fractures as￾sociated with open fractures or extensive soft tissue injuries, which is limited medial MIPO. The treatment results of the anterolateral MIPO technique were evaluated and analyzed. Materials and Methods: Seventeen patients with distal tibial fractures associated with an open fracture or large bullae formation on the distal tibia medial side were treated with anterolateral MIPO using anterolateral locking plates. Within 24 hours of visiting the emergen￾cy room, external fixation was applied, and the medial side wound was managed. After damage control, the anterolateral locking plate was applied using an anterolateral MIPO technique. The union time, nonunion, or malunion were evaluated with regular postoperative radiographs. The ankle range of motion, operative time, blood loss, Iowa score, and wound complications were investigated. Results: Radiological evidence of bony union was obtained in all cases. The mean time to union was 16.7 weeks (12∼25 weeks). The mean operation time was 44.0 minutes. Regarding the ankle range of motion, the mean dorsiflexion was 15°, and the mean plantarflex￾ion was 35°. Satisfactory results were obtained in 15 out of 17 cases; five results were classified as excellent, four were good, and six were fair. The mean blood loss was 125.2 mL. Two complications were recorded. Conclusion: In distal tibial fractures with severe medial soft tissue damage caused by high-energy trauma, the staged anterolateral MIPO technique using anterolateral locking plates is a useful alternative treatment to achieving optimal wound care, rapid union with biological fixation, and intra-articular reduction.

Abstract

Purpose: Anterolateral minimally invasive plate osteosynthesis (MIPO) was performed to treat patients with distal tibial fractures as￾sociated with open fractures or extensive soft tissue injuries, which is limited medial MIPO. The treatment results of the anterolateral MIPO technique were evaluated and analyzed. Materials and Methods: Seventeen patients with distal tibial fractures associated with an open fracture or large bullae formation on the distal tibia medial side were treated with anterolateral MIPO using anterolateral locking plates. Within 24 hours of visiting the emergen￾cy room, external fixation was applied, and the medial side wound was managed. After damage control, the anterolateral locking plate was applied using an anterolateral MIPO technique. The union time, nonunion, or malunion were evaluated with regular postoperative radiographs. The ankle range of motion, operative time, blood loss, Iowa score, and wound complications were investigated. Results: Radiological evidence of bony union was obtained in all cases. The mean time to union was 16.7 weeks (12∼25 weeks). The mean operation time was 44.0 minutes. Regarding the ankle range of motion, the mean dorsiflexion was 15°, and the mean plantarflex￾ion was 35°. Satisfactory results were obtained in 15 out of 17 cases; five results were classified as excellent, four were good, and six were fair. The mean blood loss was 125.2 mL. Two complications were recorded. Conclusion: In distal tibial fractures with severe medial soft tissue damage caused by high-energy trauma, the staged anterolateral MIPO technique using anterolateral locking plates is a useful alternative treatment to achieving optimal wound care, rapid union with biological fixation, and intra-articular reduction.

참고문헌 (17)

  1. Ahmad MA, "Percutaneous locking plates for fractures of the distal tibia : our experience and a review of the literature", J Trauma Acute Care Surg, 72, pp.E81~E87 (2012)[DOI]
  2. Borg T, "Percutaneous plating of distal tibial fractures. Preliminary results in 21 patients", Injury, 35, pp.608~614 (2004)[DOI]
  3. Collinge C, "Minimally invasive plating of high-energy metaphyseal distal tibia fractures", J Orthop Trauma, 25, pp.355~361 (2007)[DOI]
  4. Hasenboehler E, "Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture : a retrospective study of 32 patients", Injury, 38, pp.365~370 (2007)[DOI]
  5. Helfet DL, "Minimally invasive plate osteosynthesis of distal fractures of the tibia", Injury, 28(Suppl 1), pp.A42~A47 (1997)
  6. Helfet DL, "Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia", Instr Course Lect, 53, pp.471~475 (2004)
  7. 김성규, "원위 경골 골절에서 잠김 압박 금속판을 이용한 최소 침습적 골유합술", 대한골절학회지, 24(1), pp.33~40 (2011), 대한골절학회
  8. 김원유, "원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과", 대한족부족관절학회지, 16(2), pp.94~100 (2012), 대한족부족관절학회[DOI]
  9. Krackhardt T, "Fractures of the distal tibia treated with closed reduction and minimally invasive plating", Arch Orthop Trauma Surg, 125, pp.87~94 (2005)[DOI]
  10. Lau TW, "Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures", Int Orthop, 32, pp.697~703 (2008)[DOI]
  11. 이근배, "원위 경골 골절: 금속판 고정술", 대한골절학회지, 22(4), pp.306~313 (2009), 대한골절학회
  12. Oh CW, "Distal tibia metaphyseal fractures treated by percutaneous plate osteosynthesis", Clin Orthop Relat Res., (408), pp.286~291 (2003)[DOI]
  13. Yenna ZC, "Anterolateral and medial locking plate stiffness in distal tibial fracture model", Foot Ankle Int, 32, pp.630~637 (2011)[DOI]
  14. 박성기, "원위 경골 골절에 대한 단계적 최소 침습적 금속판 고정술", 대한골절학회지, 23(3), pp.289~295 (2010), 대한골절학회
  15. Redfern DJ, "Fractures of the distal tibia: minimally invasive plate osteosynthesis", Injury, 35, pp.615~620 (2004)[DOI]
  16. Ronga M, "Minimally invasive osteosynthesis of distal tibial fractures using locking plates", Orthop Clin North Am, 40, pp.499~504 (2009)[DOI]
  17. Wyrsch B, "Operative treatment of fractures of the tibial plafond. A randomized, prospective study", J Bone Joint Surg Am, 78, pp.1646~1657 (1996)[DOI]

관련 논문AI추천

원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과권오수, 길호진, 김영율, 김원유, 박상은, 정재중, 지종훈대한족부족관절학회 · 대한족부족관절학회지2012 · 제16권 제2호원위 경골 골절의 수술적 치료강도준, 정재중대한족부족관절학회 · 대한족부족관절학회지2013 · 제17권 제3호잠김-압박 금속판을 사용하여 MIPPO 수기를 적용한 원위부 경골 골절의 치료: 관절내 골절과 관절외 골절의 비교김주학, 김형수, 박재형, 유정현, 정수태, 정진하, 차승도대한족부족관절학회 · 대한족부족관절학회지2009 · 제13권 제2호경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과정형진, 추지웅대한족부족관절학회 · 대한족부족관절학회지2013 · 제17권 제2호원위 경골 골절에서 금속정 및 금속판 고정술의 결과 비교곽희철, 김정한, 이창락, 정양환대한족부족관절학회 · 대한족부족관절학회지2015 · 제19권 제3호경골 원위간부 골절 치료의 골수강내 금속정 고정술과 최소침습 금속판 고정술의 비교: 기능적, 미용적 결과의 후향적 비교김가현, 김건중, 김용민, 김인희, 김종원, 윤지영, 임성준대한족부족관절학회 · 대한족부족관절학회지2023 · 제27권 제3호

이 간행물의 다른 논문 (5건)