Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach’s alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach’s alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.
Abstract
Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach’s alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach’s alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.
참고문헌 (23)
- Fadahunsi KP, "Information quality frameworks for digital health technologies : systematic review", J Med Internet Res, 23, pp.e23479~ (2021)[DOI]
- Mickle KJ, "Foot pain, plantar pressures, and falls in older people : a prospective study", J Am Geriatr Soc, 58, pp.1936~1940 (2010)[DOI]
- 김어진, "Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children", Clinics in Orthopedic Surgery, 10(4), pp.484~490 (2018), 대한정형외과학회
- Murphy DF, "Efficacy of plantar loading parameters during gait in terms of reliability, variability, effect of gender and relationship between contact area and plantar pressure", Foot Ankle Int, 26, pp.171~179 (2005)[DOI]
- Ramanathan AK, "Repeatability of the Pedar-X in-shoe pressure measuring system", Foot Ankle Surg, 16, pp.70~73 (2010)[DOI]
- Hsiao H, "Accuracy and precision of two in-shoe pressure measurement systems", Ergonomics, 45, pp.537~555 (2002)[DOI]
- Putti AB, "The Pedar in-shoe system : repeatability and normal pressure values", Gait Posture, 25, pp.401~405 (2007)[DOI]
- Kernozek TW, "Reliability of an in-shoe pressure measurement system during treadmill walking", Foot Ankle Int, 17, pp.204~209 (1996)[DOI]
- Marshall SJ, "Translating physical activity recommendations into a pedometer-based step goal : 3000 steps in 30 minutes", Am J Prev Med, 36, pp.410~415 (2009)[DOI]
- Cicchetti DV, "Developing criteria for establishing interrater reliability of specific items : applications to assessment of adaptive behavior", Am J Ment Defic, 86, pp.127~137 (1981)
- George D, "SPSS for Windows step by step : a simple guide and reference 11.0 update" (2003), Allyn and Bacon
- Marey ÉJ, "De la locomotion terrestre chez les bipèdes et les quadrupèdes" (1873), Editeur inconnu
- Salpavaara T, "Wireless insole sensor system for plantar force measurements during sport events", Paper presented at : IMEKO XIX World Congress on Fundamental and Applied Metrology, pp.2118~2123 (2009)
- MacWilliams BA, "Clinical applications of plantar pressure measurement in pediatric orthopedics", Paper presented at: Pediatric Gait, A new Millennium in Clinical Care and Motion Analysis Technology, pp.143~150 (2000)
- Razak AH, "Foot plantar pressure measurement system : a review", Sensors(Basel), 12, pp.9884~9912 (2012)[DOI]
- Gefen A, "Pressure-sensing devices for assessment of soft tissue loading under bony prominences : technological concepts and clinical utilization", Wounds, 19, pp.350~362 (2007)
- Barnett S, "A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform", Clin Biomech(Bristol, Avon), 16, pp.353~357 (2001)[DOI]
- Frykberg RG, "Feasibility and efficacy of a smart mat technology to predict development of diabetic plantar ulcers", Diabetes Care, 40, pp.973~980 (2017)[DOI]
- Najafi B, "Smarter sole survival : will neuropathic patients at high risk for ulceration use a smart insole-based foot protection system?", J Diabetes Sci Technol, 11, pp.702~713 (2017)[DOI]
- Macdonald EM, "Factors influencing Australian podiatrists’ behavioural intentions to adopt a smart insole into clinical practice : a mixed methods study", J Foot Ankle Res, 13, pp.28~ (2020)[DOI]
- Chatzaki C, "The Smart-Insole dataset : gait analysis using wearable sensors with a focus on elderly and Parkinson’s patients", Sensors(Basel), 21, pp.2821~ (2021)[DOI]
- Putti AB, "Foot pressure differences in men and women", Foot Ankle Surg, 16, pp.21~24 (2010)[DOI]
- Yamamoto T, "Plantar pressure sensors indicate women to have a significantly higher peak pressure on the hallux, toes, forefoot, and medial of the foot compared to men", J Foot Ankle Res, 13, pp.40~ (2020)[DOI]