에어로졸 공정에 의한 그래핀-팔라듐 복합체 제조 및 글루코스 바이오센서 특성평가
Preparation of Graphene-Palladium Composite by Aerosol Process and It's Characterization for Glucose Biosensor
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Palladium (Pd) nanoparticles attached graphene (GR) composite was synthesized for an enhanced glucose biosensor. Aerosol spray pyrolysis (ASP) was employed to synthesize the GR-Pd composite using a colloidal mixture of graphene oxide (GO) and palladium chloride (PdCl2) precursor. The effects of the weight ratio of the Pd/GR on the particle properties including the morphology and crystal structure were investigated. The morphology of GR-Pd composites was generally the shape of a crumpled paper ball, and the average composite size was about 1 µm. Pd nanoparticles less than 20 nm in diameter were deposited on GR sheets and the Pd nanoparticles showed clear crystallinity. The characteristic of the glucose biosensor fabricated with the as-prepared GR-Pd composite was tested through cyclic voltammetry measurements. The biosensor exhibited a high current flow as well as clear redox peaks, which resulted in a superior ability of the catalyst in terms of an electrochemical reaction. The highest sensitivity obtained from the amperometric response of the glucose biosensor was 14.4 µA/mM·㎠.
Abstract
Palladium (Pd) nanoparticles attached graphene (GR) composite was synthesized for an enhanced glucose biosensor. Aerosol spray pyrolysis (ASP) was employed to synthesize the GR-Pd composite using a colloidal mixture of graphene oxide (GO) and palladium chloride (<TEX>$PdCl_2$</TEX>) precursor. The effects of the weight ratio of the Pd/GR on the particle properties including the morphology and crystal structure were investigated. The morphology of GR-Pd composites was generally the shape of a crumpled paper ball, and the average composite size was about <TEX>$1{\mu}m$</TEX>. Pd nanoparticles less than 20 nm in diameter were deposited on GR sheets and the Pd nanoparticles showed clear crystallinity. The characteristic of the glucose biosensor fabricated with the as-prepared GR-Pd composite was tested through cyclic voltammetry measurements. The biosensor exhibited a high current flow as well as clear redox peaks, which resulted in a superior ability of the catalyst in terms of an electrochemical reaction. The highest sensitivity obtained from the amperometric response of the glucose biosensor was <TEX>$14.4{\mu}A/mM{\cdot}cm^2$</TEX>.
참고문헌 (20)
- Chen, Y., "Fabrication of gold nanoparticles on bilayer graphene for glucose electrochemical biosensing", Journal of Materials Chemistry, 21, pp.7604~7610 (2011)
- Cote, L. J., "Flash reduction and patterning of graphite oxide and its polymer composite", Journal of the American Chemical Society, 131, pp.11027~11032 (2009)
- Hummers, W. S., "Preparation of graphitic oxide", Journal of the American Chemical Society, 80, pp.1339~ (1958)
- Jang, H. D., "A glucose biosensor based on TiO2-graphene composite", Biosensors and Bioelectronics, 38, pp.184~188 (2012)
- Jang, H. D., "Synthesis of graphene based noble metal composites for glucose biosensor", Materials Letters, 106, pp.277~280 (2013)
- Jia, F., "Carbon nanotube", gold nanoparticles, Biosensors and Bioelectronics, pp.2008, 24[DOI]
- Kim, S. K., "Aerosol processing of graphene and its application to oil absorbent and glucose biosensor", KONA Powder and Particle Journal, 31, pp.111~125 (2014)
- Kuila, T., "Recent advances in graphene-based biosensors", Biosensors and Bioelectronics, 26, pp.4637~4648 (2011)
- Kuila, T., "Chemical functionalization of graphene and its applications", Progress in Materials Science, 57, pp.1061~1105 (2012)
- Lim, S. H., "A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode", Biosensors and Bioelectronics, 20, pp.2341~2346 (2005)
- Lu, J., "Nanometal-decorated exfoliated graphite nanoplatelet based glucose biosensors with high sensitivity and fast response", ACS Nano, 2, pp.1825~1832 (2008)
- O’Neill, R. D., "Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate", Biosensors and Bioelectronics, 19, pp.1521~1528 (2004)
- Shan, C., "Graphene", AuNPs, Biosensors and Bioelectronics, pp.2010, 25[DOI]
- Singh, V., "Graphene based materials : Past, present and future", Progress in Materials Science, 56, pp.1178~1271 (2011)
- Wang, J., "Electrochemical Glucose Biosensors", Chemical Reviews, 108, pp.814~825 (2008)
- Wu, B., "Noble metal nanoparticles", carbon nanotubes nanohybrids : synthesis and applications, 2011, pp.6, 75~90
- Yang, M. H., "Development of a glucose biosensor using advanced electrode modified by nanohybrid composing chemically modified graphene and ionic liquid", Electroanalysis, 22, pp.1223~1228 (2010)
- Yang, J., "Electrochemical synthesis of reduced graphene sheet–AuPd alloy nanoparticle composites for enzymatic biosensing", Biosensors and Bioelectronics, 29, pp.159~166 (2011)
- Zeng, Q., "Palladium nanoparticle", chitosangrafted graphene nanocomposites for construction of a glucose biosensor, 2011, pp.26, 3456~3463
- Zhou, K., "A novel hydrogen peroxide biosensor based on Au-graphene-HRP-chitosan biocomposites", Electrochimica Acta, 55, pp.3055~3060 (2010)