Evaluation of Analyzer and Measurement Conditions of Blood Ammonia

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타자연과학

초록

Ammonia is very toxic, and causes neuronal damage via excitotoxicity, oxidative stress, and inflammation. Because the liver is the primary organ for ammonia metabolism, compromised liver function can result from inborn errors of metabolism. Measurement of blood ammonia has some limitations. Recently, several laboratories examined possible concurrent increases in plasma ammonia. However, the collection, handling, storage, and analysis of blood samples are all potential sources of error. For evaluation of rapidity and reliability of measurement of blood ammonia, the DRI-CHEM 100 (Fuji Film Co., Japan) and COBAS 8000 (Roche Diagnostic Ltd., Switzerland) analyzer were used for analysis of ammonia level values. The results of this study detected a high correlation between analyzer. Therefore, one-step measurement was suitable for ammonia analysis. After sampling of the ammonia in the time slot for measurement an increase to 46.5, 57.4, and 79.0 (μg/dL) was observed at 30, 90, and 180 minutes. In addition, specific capacity of the ammonia, 7, 10, and 13 (μL), was measured as 39, 46, and 43 (μg/dL), respectively, and the FDC-100 analyzer was more effective in 10 μL (p<0.001). In conclusion, the evaluated analysis may offer useful information for clinical application.

Abstract

Ammonia is very toxic, and causes neuronal damage via excitotoxicity, oxidative stress, and inflammation. Because the liver is the primary organ for ammonia metabolism, compromised liver function can result from inborn errors of metabolism. Measurement of blood ammonia has some limitations. Recently, several laboratories examined possible concurrent increases in plasma ammonia. However, the collection, handling, storage, and analysis of blood samples are all potential sources of error. For evaluation of rapidity and reliability of measurement of blood ammonia, the DRI-CHEM 100 (Fuji Film Co., Japan) and COBAS 8000 (Roche Diagnostic Ltd., Switzerland) analyzer were used for analysis of ammonia level values. The results of this study detected a high correlation between analyzer. Therefore, one-step measurement was suitable for ammonia analysis. After sampling of the ammonia in the time slot for measurement an increase to 46.5, 57.4, and 79.0 (μg/dL) was observed at 30, 90, and 180 minutes. In addition, specific capacity of the ammonia, 7, 10, and 13 (μL), was measured as 39, 46, and 43 (μg/dL), respectively, and the FDC-100 analyzer was more effective in 10 μL (p<0.001). In conclusion, the evaluated analysis may offer useful information for clinical application.

참고문헌 (20)

  1. Souba WW, "Interorgan ammonia metabolism in health and disease : a surgeon's view", J Parenter Enteral Nutr, 11, pp.569~579 (1987)
  2. Hai-Xing Jiang, "Association of Helicobacter pylori with Elevated Blood Ammonia Levels in Cirrhotic Patients: A Meta-Analysis", Yonsei Medical Journal, 54(4), pp.832~838 (2013), 연세대학교의과대학[DOI]
  3. Qureshi MO, "Ammonia levels and the se verity of hepatic encephalopathy", J Coll Physicians Surg Pak, 24, pp.160~163 (2014)
  4. Häberle J, "Clinical practice: the management of hyperammonemia", Eur J Pediatr, 170, pp.21~34 (2011)
  5. Tomita K, "Clinical significance of plasma ammonia in patients with generalized convulsion", Intern Med, 50, pp.2297~2301 (2011)
  6. Hibbard T1, "Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors", Anal Chem, 85, pp.12158~12165 (2013)
  7. Donaldson AE, "Biochemistry changes that occur after death: potential markers for determining post-mortem interval", PLoS One, 8, pp.e82011~ (2013)
  8. Drolz A, "Clinical impact of arterial ammonia levels in ICU patients with different liver diseases", Intensive Care Med, 39, pp.1227~1237 (2013)
  9. El-Khoury JM, "Is the effect of hemolysis on plasma ammonia measurement overrated?", Arch Pathol Lab Med, 136, pp.471~472 (2012)
  10. Dimeski G, "Interference testing", Clin Biochem Rev, 29, pp.S43~S48 (2008)
  11. Barsotti RJ, "Measurement of ammonia in blood", J Pediatr, 138(1 Suppl), pp.S11~S19 (2001)
  12. Ye JL, "Changes of ammonia levels in patients with acute on chronic liver failure treated by plasma exchange", Hepatogastroenterology, 61, pp.141~145 (2014)
  13. Shin CH, "Quantitative analysis in plasma ammonia", Korean Journal of Medical Technologists, 3, pp.36~41 (1971)
  14. Jones PM, "Altered mental status in a teenager", Clin Chem, 59, pp.1442~1444 (2013)
  15. Roquilly A, "Ammonia plasma concentration and prolonged infusion of remifentanil in patients with acute kidney injury", Minerva Anestesiol, 79, pp.884~890 (2013)
  16. Jóźwik M, "Ammonia and female sex hormones concentrations in human preovulatory follicular fluid are not directly related", Ginekol Pol, 83, pp.899~903 (2012)
  17. Kasai A, "Prognostic value of venous blood ammonia in patients with out-of-hospital cardiac arrest", Circ J, 76, pp.891~899 (2012)
  18. Cho YM, "Blood ammonia is a predictive biomarker of neurologic outcome in cardiac arrest patients treated with therapeutic hypothermia", Am J Emerg Med, 30, pp.1395~1401 (2012)
  19. Blanco Vela Cl, "Determination of ammonia concentrations in cirrhosis patients-still confusing after all these years?", Ann Hepatol, 10(Suppl 2), pp.S60~S65 (2011)
  20. 안병락, "일반화학검사를 위한 혈청의 보관 시간 및 온도에 따른 영향", 대한임상검사과학회지, 46(4), pp.111~116 (2014), 대한임상검사과학회

관련 논문AI추천

이 간행물의 다른 논문 (17건)