초록

.

Abstract

Methotrexate (MTX) in one of the antineoplastic drug and it is known to effective to management of acute lymphoblastic leukemia in children, management of choriocarcinoma and related trophoblastic tumors in women, management of carcinomas of the breast, tongue, pharynx, and tests, maintenance of remission in leukemia and treatment of serve, debilitating psoriasis. Intermediate to high-dose methotrexate administration followed by leucovorin rescue is effective in treatment of carcinoma of the lung and osteogenic sarcoma. Intrathecal administration is effective in treating meningeal leukemia or lymphoma. There are FPIA (Fluorescence polarization immunoassay) and EMIT (Enzyme multiplied immunotechique) methods that measure for MTX. We evaluated the FPIA and EMIT methods. MTX were measured by Hitachi-7600 P-module using EMIT and FPIA using TDX in the sera 60 patients. The performance characteristics evaluated were, light influence, linearity, comparison with FPIA. Also, precision evaluated were three level controls through put following CLSI evaluation protocols (EP10-A). When the MTX value of 4.16±5.78 μμmol/L (mean, SD) by the Hitachi-7600 P-module was compared with that of 4.05±5.47 μμ mol/L by FPIA, coefficients of correlation of 0.988 was obtained. The regression equation was Y (Hitachi-7600 P-module) = 0.9408 x (FPIA) + 0.1316 (r=0.9885, n=60). CVs of MTX measured by Hitachi 7600 P-module was 6.78% at 0.33 μμmol/L, 0.96% at 1.16 μμmol/L, and 0.96% at 8.04 μμmol/L. The precision was excellent in each group. The linearity was acceptable. We evaluated that MTX is light-sensitive on prolonged exposure to direct sunlight. Comparing with the FPIA using TDX, the Hitachi-7600 P-module using EMIT showed good coefficient of correlation and precision. Therefore the Hitachi-7600 P-module can replace the FPIA for quantitative analysis of MTX.

참고문헌 (16)

  1. Beller GA, "Digitalis intoxication. A prospective clinical study with serum level correlations", N Eng J Med, 284, pp.989~997 (1971)
  2. Buice RG, "Evaluation of enzyme immunoassay, radioassay, and radioimmunoassay of serum methotrexate, as compared with liquid chromatography", Clin Chem, 26, pp.1902~1904 (1980)
  3. Crom WR, "Individualizing Drug Therapy: Practical Applications of Drug Monitoring", pp.149~173 (1981), Townsend, Frank, Inc
  4. Evans WE, "Applied Therapeutics" (1992)
  5. Eadie MJ, "Therapeutic drug monitoring-antiepileptic drugs", Br J Clin Pharmacol, 52(Suppl 1), pp.11S~20S (2001)
  6. Albertioni F, "Evaluation of clinical assays for measuring high-dose methotrexate in plasma", Clin Chem, 42(1), pp.39~44 (1996)
  7. Oellerich M, "Enzyme immunoassays in clinical chemistry: present status and trends", J Clin Chem Clin Biochem, 18(4), pp.197~208 (1980)
  8. OSHA, "Occupational exposure to bloodborne pathogens-OSHA. Final rule. Part II; Department of Labor, Occupational Safety and Health Administration (OSHA); 29 CFR Part 1910.1030", Fed Regist, 56(235), pp.64004~64182 (1991)
  9. Robinson JD, "A Textbook For The Clinical Application of Therapeutic Drug Monitoring", pp.31~45 (1986), Abbott Laboratories
  10. Spector R, "Therapeutic drug monitoring", Clin Pharmacol Ther, 43(3), pp.345~353 (1988)
  11. Allwood M, "The cytotoxics handbook by Michael Allwood", Andrew Stanley, Patricia Wright, ~ (2002)
  12. Wolf BA, "Overview of therapeutic drug monitoring and biotechnologic drugs", Ther Drug Monit, 18, pp.402~404 (1996)
  13. 신재국, "적정약물요법과 TDM", 대한의학협회지, 37(2), pp.170~180 (1994)
  14. 윤영란, "적정약물요법을 위한 TDM의 임상적이용", 임상약리학회지, 8(1), pp.132~143 (2000)
  15. 이귀녕, "임상화학" (1988), 의학문화사
  16. 장인진, "임상약리학", pp.29~ (1995), 서울대학교 출판부

관련 논문AI추천