Postmortem Computed Tomography 영상을 이용한 한국인 영아 체중 추정 방법 연구: 부피 및 곱셈 인자의 활용
Postmortem Computed Tomography–Based Body Weight Estimation in Korean Infants Using Volume and Multiplication Factors
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Postmortem computed tomography (PMCT) is used in forensic medicine worldwide due to its ability to non-invasively visualize injuries, hemorrhage, and estimate volume. In the autopsy of infants, assessing nutritional conditions such as weight is crucial for identifying neglect. This study aims to evaluate the usefulness of retrospectively estimating the weight of Korean infants using PMCT-based volume and multiplication factors, even when the body has been cremated. A total of 44 cases of infant death (under 12 months) were analyzed. PMCT images were obtained before autopsy. Autopsy records and documentation provided by the police at the time of autopsy were reviewed to determine the weight (g) of the infant. PMCT-based infant volumes (mL) were estimated using a three-dimensional semi-automatic segmentation method. Multiplication factors (g/mL) were calculated by dividing the weight recorded at autopsy by the PMCT-based volume, yielding a mean of 1.047 g/mL, ranging from 1.014 g/ mL to 1.085 g/mL. The mean absolute error compared to weights recorded at autopsy was 95 g. Significant discrepancies were observed between weights recorded at the scene or medical center and those measured at autopsy. This study demonstrates that PMCT-based weight estimation for Korean infants is a reliable method and has the potential for retrospectively validating incorrect weight measurements and addressing inconsistencies in recorded weight data.
Abstract
Postmortem computed tomography (PMCT) is used in forensic medicine worldwide due to its ability to non-invasively visualize injuries, hemorrhage, and estimate volume. In the autopsy of infants, assessing nutritional conditions such as weight is crucial for identifying neglect. This study aims to evaluate the usefulness of retrospectively estimating the weight of Korean infants using PMCT-based volume and multiplication factors, even when the body has been cremated. A total of 44 cases of infant death (under 12 months) were analyzed. PMCT images were obtained before autopsy. Autopsy records and documentation provided by the police at the time of autopsy were reviewed to determine the weight (g) of the infant. PMCT-based infant volumes (mL) were estimated using a three-dimensional semi-automatic segmentation method. Multiplication factors (g/mL) were calculated by dividing the weight recorded at autopsy by the PMCT-based volume, yielding a mean of 1.047 g/mL, ranging from 1.014 g/ mL to 1.085 g/mL. The mean absolute error compared to weights recorded at autopsy was 95 g. Significant discrepancies were observed between weights recorded at the scene or medical center and those measured at autopsy. This study demonstrates that PMCT-based weight estimation for Korean infants is a reliable method and has the potential for retrospectively validating incorrect weight measurements and addressing inconsistencies in recorded weight data.
참고문헌 (13)
- Ebert LC, "Image segmentation of post-mortem computed tomography data in forensic imaging : methods and applications", Forensic Imaging, 28, pp.200483~ (2022)
- Heo JH, "Examination of the cerebellomedullary cistern using postmortem computed tomography in various types intracranial hemorrhage", Korean J Leg Med, 47, pp.105~109 (2023)
- Yang KM, ""Buckle"rib fracture : an artifact following cardio-pulmonary resuscitation detected on postmortem CT", Leg Med(Tokyo), 13, pp.233~239 (2011)
- Huh GY, "Education and training of clinical forensic examination in the management of child abuse in Korea : comparison with Germany, the United Kingdom, Australia, and the United States of America", Korean J Leg Med, 47, pp.87~94 (2023)
- Piercecchi-Marti MD, "Malnutrition, a rare form of child abuse : diagnostic criteria", J Forensic Sci, 51, pp.670~673 (2006)
- Jackowski C, "Body weight estimation based on postmortem CT data : validation of a multiplication factor", Int J Legal Med, 129, pp.1121~1125 (2015)
- Hagen F, "Correlation between liver volume and liver weight in a cohort with chronic liver disease : a semiautomated CT-volumetry study", Quant Imaging Med Surg, 12, pp.376~383 (2022)
- Ichikawa S, "A deep-learning method using computed tomography scout images for estimating patient body weight", Sci Rep, 11, pp.15627~ (2021)
- Heo JH, "The significance of evaluating sphenoid sinus fluid by postmortem computed tomography in cases of drowning", J Forensic Leg Med, 97, pp.102551~ (2023)
- Lee S, "Estimation of stature from femur length measured using computed tomography after the analysis of three-dimensional characteristics of femur bone in Korean cadavers", Int J Legal Med, 131, pp.1355~1362 (2017)
- Pham CV, "Age estimation based on 3D post-mortem computed tomography images of mandible and femur using convolutional neural networks", PLoS One, 16, pp.e0251388~ (2021)
- Ebert LC, "Automatic detection of hemorrhagic pericardial effusion on PMCT using deep learning : a feasibility study", Forensic Sci Med Pathol, 13, pp.426~431 (2017)
- Heo JH, "U-Net-based automatic segmentation of sphenoid sinus fluid in drowning cases using postmortem CT images : a feasibility study", Korean J Leg Med, 48, pp.7~13 (2024)
