Simple Electrochemical Immunosensor for the Detection of Hippuric Acid on the Screen-printed Carbon Electrode Modified Gold Nanoparticles
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This paper describes an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in tolueneexposed humans. The feature of this electrochemical system for immunoassay of hippuric acid is based on the direct conjugation of ferrocene to a hippuric acid. With the competition between the ferrocene-hippuric acid complex and hippuric acid for binding to the anti-hippuric acid monoclonal antibody coated onto gold nanoparticles, the electrical signals are turned out to be proportional to urinary hippuric acid in the range of 0.01-10 mg/mL, which is enough to be used for the point-of-care. The proposed electrochemical method could extend its applications to detect a wide range of different small molecules of antigens in the health care area.
Abstract
This paper describes an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in tolueneexposed humans. The feature of this electrochemical system for immunoassay of hippuric acid is based on the direct conjugation of ferrocene to a hippuric acid. With the competition between the ferrocene-hippuric acid complex and hippuric acid for binding to the anti-hippuric acid monoclonal antibody coated onto gold nanoparticles, the electrical signals are turned out to be proportional to urinary hippuric acid in the range of 0.01-10 mg/mL, which is enough to be used for the point-of-care. The proposed electrochemical method could extend its applications to detect a wide range of different small molecules of antigens in the health care area.
참고문헌 (25)
- J. W. Boor, "Permanent cerebellar ataxiaafter exposure to toluene’", Ann. Neurol, 2, pp.440~ (1977)
- N. L. Rosenberg, "Central nervous system effects ofchronic toluene abuse-clinical, brainstem evoked responseand magnetic -resonance imaging studies", Neurotoxicol.Teratol, 10, pp.489~ (1988)
- R. G. Feldman, "Chronic toxicencephalopathy in a painter exposed to mixed solvents", Environmental Health Perspectives, 107, pp.417~ (1999)
- 유기열, "Immunochromatographic analysis of hippuric acid in urine", JOURNAL OF ANALYTICAL TOXICOLOGY, 31, pp.347~353, PRESTON PUBL INC
- P. Kongtip, "Modified method for determination of hippuric acid andmethylhippuric acid in urine by gas chromatography’", JChromatogr B Biomed Sci Appl, 751, pp.199~ (2001)
- K. Tomokuni, "Direct ColorimetricDetermination of Hippuric Acid in Urine’", Clin Chem, 18, pp.349~ (1972)
- T. Sakai, "Simultaneous determination of hippuric acid and o-, mandp-methylhippuric acids in urine by high-performanceliquid chromatography’", J Chromatogr, 276, pp.182~ (1983)
- A. C. Lee, "Sensitive electrochemical detection of horseradishperoxidase at disposable screen-printed carbon electrode", Electroanalysis, 20, pp.2040~ (2008)
- Y. Y. Lin, "Label", immunochromatographic electrochemical biosensorfor rapid and sensitive detection of prostate-specificantigen’, 2008, pp.23, 1659~
- S. Prabhulkar, "Amperometric micro-immunosensor for the detection oftumor biomarker’", Biosensor and Bioelectronics, 24, pp.3524~ (2009)
- S. J. Yoo, "Microfluidic chip-based electrochemical immunoassay for hippuric acid", ANALYST, 134, pp.2462~2467 (2009), ROYAL SOC CHEMISTRY
- J. Wang, "Electrochemical enzyme immunoassays on microchipplatforms’", Anal Chem, 73, pp.5323~ (2001)
- C. Duan, "Immobilization of proteinson gold Coated Porous Membranes Via an ActivatedSelf-Assembled Monolayer of Thioctic acid’", Anal Chem, 66, pp.1369~ (1994)
- T. J. Moore, "Enzymically Amplified Voltammetric Sensor for MicroliterSample Volumes of Salicylate’", Anal Chem, 67, pp.1896~ (1995)
- J. Wang, "Thick-film electrochemicalimmunosensor based on stripping potentiometricdetection of a metal ion label", Anal Chem, 70, pp.1682~ (1998)
- T. K. Lim, "Construction of electrochemicalflow immunoassay system using capillary columnsand ferrocene conjugated immunoglobulin G for detectionof human chorionic gonadotrophin’", Biosens Bioelectron, 16, pp.1063~ (2001)
- T. K. Lim, "‘Miniaturizedamperometric flow immunoassay system using a glassfiber membrane modified with anion", Biotechnol Bioeng, 77, pp.758~ (2002)
- T. K. Lim, "MicrofabricatedOn-Chip-Type Electrochemical Flow Immunoassay Systemfor the Detection of Histamine Released in Whole BloodSamples", Anal Chem, 75, pp.3316~ (2003)
- S. Purushothama, "Small Volume Bead Assayfor Ovalbumin with Electrochemical Detection’", Analyst, 126, pp.337~ (2001)
- Y. Zhang, "Reduction of the nonspecificbinding of a target antibody and of its enzyme-labeleddetection probe enabling electrochemical immunoassayof an antibody through the 7 pg", ml-100 ng, Anal Chem, pp.2005, 77[DOI]
- C. Padeste, "Ferroceneavidinconjugates for bioelectrochemical applications’", applications’Biosens Bioelectron, 15, pp.431~ (2000)
- H. C. Yoon, "Functionalizationof a poly(amidoamine) dendrimer with ferrocenyls andits application to the construction of a reagentless enzymeelectrode", Anal Chem, 72, pp.4420~ (2000)
- 김혁한, "오스뮴 착물 합성과 전기화학적인 방법을 이용한 바이오센서에 관한 연구", 전기화학회지, 10(2), pp.150~154 (2007), 한국전기화학회
- M. O. Finot, "Characterization of electrochemically deposited goldnanocrystals on glassy carbon electrodes", J ElectrochemSoc, 466, pp.234~ (1999)
- M. S. El-Deab, "Electrochemicalreduction of oxygen on gold nanoparticle-electrodepositedglassy carbon electrodes’", Electrochem Soc, 150, pp.851~ (2003)