초록
Styrene butadiene rubber solution for a binder of carbon powder and the marketed peroxidase extracted from horseradish for the biocatalyst were used to construct a biosensor to determine hydrogen peroxide. The symmetry factor (0.2), the exchange current density (2.42 × 10−5 A cm−2) and 10 and more electrode parameters were obtained for the cathodic branch of the signal current. They showed that the electrode fulfills its function normally and is not contrary to our expectations.
Abstract
Styrene butadiene rubber solution for a binder of carbon powder and the marketed peroxidase extracted from horseradish for the biocatalyst were used to construct a biosensor to determine hydrogen peroxide. The symmetry factor (0.2), the exchange current density (2.42 × 10−5 A cm−2) and 10 and more electrode parameters were obtained for the cathodic branch of the signal current. They showed that the electrode fulfills its function normally and is not contrary to our expectations.
참고문헌 (23)
- 윤길중, "EPDM으로 결합된 HRP 고정 바이오센서의 전기화학적 특성", 엘라스토머 및 콤포지트, 42(2), pp.112~118 (2007), 한국고무학회
- 윤길중, "Electrochemical Studies on the Voltammetric Characteristics of Hydrogen Peroxide Biosensor Immobilized by Natural Rubber", 대한화학회지, 52(2), pp.197~202 (2008), 대한화학회
- K. J. Yoon, "Study of Practical Use of Carbon Paste Biosensor Mechanically Reinforced by Chloroprene Rubber", Bulletin of the Korean Chemical Society, 29(11), pp.2264~2266 (2008), 대한화학회
- Beom-Gyu Lee, "Electrochemical Investigation of Carbon Paste Biosensor Bound with Natural Rubber Solution", Bulletin of the Korean Chemical Society, 30(10), pp.2457~2460 (2009), 대한화학회
- J Wang, "Glucose microsensors based on carbon paste enzyme electrodes modified with cupric hexacyanoferrate", Anal Chim Acta, 395, pp.11~16 (1999)
- KJ Yoon, "Determination of optimum pH of enzyme by electrochemical method", Anal Sci Tech, 13, pp.41~48 (2000)
- Kil-Joong Yoon*, "A New Strategy for Determining Optimum pH of Isozymes", Bulletin of the Korean Chemical Society, 25(7), pp.997~1002 (2004), 대한화학회
- S. Tingry, "Carbon paste biosensor for phenol detection of impregnated tissue: modification of selectivity by using β-cyclodextrin-containing PVA membrane", Mater Sci Eng C, 26, pp.222~226 (2006)
- Beom-Gyu Lee, "Amperometric study of hydrogen peroxide biosensor with butadiene rubber as immobilization matrix", Journal of Industrial and Engineering Chemistry, 16(3), pp.340~343 (2010), 한국공업화학회
- 유근배, "Amperometric Kinetics of Hydrogen Peroxide Biosensor Bound with Natural Rubber", 공업화학, 21(6), pp.689~693 (2010), 한국공업화학회
- Kil-Joong Yoon, "Electrochemical Investigation of Animal Tissue Embedded Biosensor Bound with Ethylene-Propylene Rubber", Bulletin of the Korean Chemical Society, 31(10), pp.2913~2917 (2010), 대한화학회
- 윤길중, "부틸고무를 결합재로 사용한 바이오센서의 전기화학적 성질", 엘라스토머 및 콤포지트, 41(4), pp.231~237 (2006), 한국고무학회
- NR Anatoly, "FET-microbial sensor for xylose detection based on gluconobacter oxydans cells", Biosensors & Bioelectrinics, 11, pp.401~408 (1996)
- Z Wang, "Feasibility of protein A for the oriented immobilization of immunoglobulin of silicon surface for a biosensor with imaging ellipsometry", J Biochem Biophys Methods, 57, pp.203~211 (2003)
- L Su, "Amperometric glucose sensor based on enzyme-modified boron-doped diamond electrode by cross-linking method", Sens Actuators B, 99, pp.499~504 (2004)
- D Ogoñczyk, "Screen-printed disposable urase-based biosensors for inhibitive detection of heavy metal ions", Sens Actuators B, 99, pp.103~450 (2005)
- E Crouch, "Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon inc incorporating glucose oxidase", Anal Biochem, 347, pp.17~23 (2005)
- VC Sanz, "Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes Application to the measurement of a bioelectrochemical polyphenols index in wines", Anal Chim Acta, 528, pp.1~8 (2005)
- JA Brydson, "Rubbery Materials and their Compounds", pp.108~ (1988), Elsevier Applied Science
- JR Kirchner, "Encyclopedia of Chemical Technology Vol. 13", pp.12~ (1981), Wiley-Interscience
- NI Sax, "Hawley’s Condensed Chemical Dictionary", pp.618~ (1987), Van Nostrand Reinhold
- A Mansouri, "Determination of hydrogen peroxide scavenging activity of cinnamic and benzoic acids employing a highly sensititive peroxyoxalate chemiluminescence-based assay: Structure-activity relationships", J Pham Bio Anal, 39, pp.22~26 (2005)
- 윤길중, "Electrochemical kinetic study of amperometric hydrogen peroxide biosensor fabricated using SBR", Journal of Industrial and Engineering Chemistry, 17(2), pp.254~258 (2011), 한국공업화학회