대형 서점 내 서적 종류 및 가구배치에 따른 포름알데히드 발생 특성

Formaldehyde Concentration Characteristics according to Type of Books and Furniture Arrangement in Bookstores

1

조회

0

다운로드

3

인용

0

참고문헌

초록

Utilization of underground floor is becoming the main issue of our society to maximize and diversify the potential of recent urban space. It has brought about the changes of underground floor. Recently there are lots of huge bookstores in these underground floor. Bleach, adhesive and ink used for manufacturing books pollute indoor air in bookstore. Therefore, the purpose of this study is to analyze indoor air quality in these large bookstores. Concentrations of carbon dioxide and formaldehyde in three large bookstores in Seoul were measured by presence and type of books and distance of main entrance which is well-ventilated. According to the data, space that places lots of volumes measured higher concentration of formaldehyde than that of non-existence books. Children’s book section was measured more concentration of formaldehyde than other book section. Closer main entrance near outside, lower concentration of formaldehyde was measured. Concentration of carbon dioxide was affected by the number of people in bookstore.

Abstract

book store, Indoor Air Quality (IAQ), formaldehyde, carbon dioxide

참고문헌 (5)

  1. 환경부, "다중이용시설 등의 실내공기질관리법 시행규칙", ~ (2004)
  2. 박귀남, "도심 지하공간의 이용실태와 만족도의 인식에 관한 조사분석 연구 : 서울시 지하상가를 중심으로", 석사, pp.2010
  3. 여락규, "지하상업공간의 공기오염물질이 인체에 미치는 영향 분석", 대한건축학회논문집 계획계, 24(11), pp.321~328 (2008), 대한건축학회
  4. 김미경, "폼알데히드 오염에 의한 학교 실내공기질 평가", 한경관리학회지, 13(1), pp.35~40 (2007)
  5. 박승엽, "흡연에 따른 커피 전문점 내부 위치별 실내공기질 분석", 한국생활환경학회지, 18(5), pp.519~528 (2011), 한국생활환경학회

관련 논문AI추천

이 간행물의 다른 논문 (17건)