Purpose: The purpose of this study was to identify the noise level and frequency experienced by premature infants receiving incubator care in the neonatal intensive care unit (NICU). Methods: The participants were 20 premature infants receiving incubator care in the NICU of a university hospital in Daejeon Metropolitan city. The noise level was measured using a professional sound-level meter (ET-958, FLUS, Shenzhen, China) based on a noise classification table developed by the author. The data were analyzed with descriptive statistics, the t-test, analysis of variance, and Pearson correlation coefficients using SPSS for Windows version 22.0. Results: The average noise level experienced by premature infants receiving incubator care in the NICU was 51.25 dB (range: 45.0~81.7 dB). The frequency of noises was highest for factors related to nursing activities (40.3%), followed by human factors (29.1%), machine alarm sounds (20.1%), incubator operation (6.6%), and internal environmental factors (3.9%). Conclusion: According to the above results, the noise level experienced by premature infants receiving incubator care in the NICU exceeded the recommendations of the American Academy of Pediatrics. Therefore, it is necessary to develop an interventional program to reduce noise in the NICU, and to conduct follow-up studies to verify its effectiveness.

Abstract

Purpose: The purpose of this study was to identify the noise level and frequency experienced by premature infants receiving incubator care in the neonatal intensive care unit (NICU). Methods: The participants were 20 premature infants receiving incubator care in the NICU of a university hospital in Daejeon Metropolitan city. The noise level was measured using a professional sound-level meter (ET-958, FLUS, Shenzhen, China) based on a noise classification table developed by the author. The data were analyzed with descriptive statistics, the t-test, analysis of variance, and Pearson correlation coefficients using SPSS for Windows version 22.0. Results: The average noise level experienced by premature infants receiving incubator care in the NICU was 51.25 dB (range: 45.0~81.7 dB). The frequency of noises was highest for factors related to nursing activities (40.3%), followed by human factors (29.1%), machine alarm sounds (20.1%), incubator operation (6.6%), and internal environmental factors (3.9%). Conclusion: According to the above results, the noise level experienced by premature infants receiving incubator care in the NICU exceeded the recommendations of the American Academy of Pediatrics. Therefore, it is necessary to develop an interventional program to reduce noise in the NICU, and to conduct follow-up studies to verify its effectiveness.

참고문헌 (30)

  1. "2018 annual report on live births and deaths statistics" (2019)[URL]
  2. Olejnik BK, "Inadvertent noise in neonatal intensive care unit and its impact on prematurely born infants", Biomedical Journal of Scientific and Technical Research, 11(2), pp.8346~8350 (2018)[DOI]
  3. Pineda RG, "Patterns of altered neurobehavior in preterm infants within the neonatal intensive care unit", The Journal of Pediatrics, 162(3), pp.470~476 (2013)[DOI]
  4. Sa MM, "Noise in an intensive care nursery", newborn unit, 2018, pp.6(2), 265~
  5. Wachman EM, "The effects of noise on preterm infants in the NICU", Archives of Disease in Childhood-Fetal and Neonatal Edition, 96(4), pp.F305~F309 (2011)[DOI]
  6. Wang D, "Examining the effects of a targeted noise reduction program in a neonatal intensive care unit", Archives of Disease in Childhood-Fetal and Neonatal Edition, 99(3), pp.F203~F208 (2014)[DOI]
  7. Graven SN, "Auditory development in the fetus and infant", Newborn and Infant Nursing Reviews, 8(4), pp.187~193 (2008)[DOI]
  8. Cardoso SM, "Newborn physiological responses to noise in the neonatal unit", Brazilian Journal of Otorhinolaryngology, 81(6), pp.583~588 (2015)[DOI]
  9. Shimizu A, "Sound environments surrounding preterm infants within an occupied closed incubator", Journal of Pediatric Nursing, 31(2), pp.e149~e154 (2016)[DOI]
  10. Beken S, "Negative effects of noise on NICU graduates' cochlear functions", Fetal and Pediatric Pathology, 25, pp.1~10 (2020)[DOI]
  11. Heidelise Als, "Toward a synactive theory of development: Promise for the assessment and support of infant individuality", Infant Mental Health Journal, 3(4), pp.229~243 (1982), Wiley[DOI]
  12. Calikusu Incekar M, "The effect of training on noise reduction in neonatal intensive care units", Journal for Specialists in Pediatric Nursing, 22(3), pp.e12181~ (2017)[DOI]
  13. Carvalhais C, "Is there sufficient training of health care staff on noise reduction in neonatal intensive care units? A pilot study from neonoise project", Journal of Toxicology and Environmental Health, 78(13-14), pp.897~903 (2015)[DOI]
  14. Casavant SG, "Noise in the neonatal intensive care unit : What does the evidence tell us", Advances in Neonatal Care, 17(4), pp.265~273 (2017)[DOI]
  15. Jayamanne C, "Determinants of noise level in the neonatal intensive care unit at Castle Street Hospital for Women, Colombo, a level III tertiary care facility", Sri Lanka Journal of Child Health, 48(4), pp.312~315 (2019)[DOI]
  16. Committee on Environmental Health, "Noise : A hazard for the fetus and newborn", Pediatrics, 100(4), pp.724~727 (1997)[DOI]
  17. Parra J, "Sound levels in a neonatal intensive care unit significantly exceeded recommendations, especially inside incubators", Acta Paediatrica, 106(12), pp.1909~1914 (2017)[DOI]
  18. Susilaningsih F, "Lighting and noise levels in the neonatal intensive care unit (NICU)", Indian Journal of Public Health Research and Development, 10(9), pp.878~882 (2019)[DOI]
  19. Hernandez-Molina R, "Effect of filters on the noise generated by continuous positive airway pressure delivered via a helmet", Noise and Health, 19(86), pp.20~23 (2017)[DOI]
  20. Lee HJ, "The effects of NICU noises on the physiological responses and behavioral state of premature babies", Master, pp.1997
  21. Cheong JLY, "Early environment and long-term outcomes of preterm infants", Journal of Neural Transmission, 127(1), pp.1~8 (2020)[DOI]
  22. Ahamed MF, "Noise reduction in the neonatal intensive care unit : A quality improvement initiative", American Journal of Medical Quality, 33(2), pp.177~184 (2018)[DOI]
  23. Weis J, "Reducing noise through awareness in the NICU", Developmental Observer, 12(1), pp.13~ (2019)[DOI]
  24. Kim EK, "NICU nurses' perception on noise and noise control behaviors", Master, pp.2008
  25. Lasky RE, "Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit", Pediatrics, 123(2), pp.540~546 (2009)[DOI]
  26. Biabanakigoortani A, "Effect of peer education on the noise management in Iranian neonatal intensive care unit", Iranian Journal of Nursing and Midwifery Research, 21(3), pp.317~321 (2016)[DOI]
  27. Goldstein J, "Ambient noise production by high-frequency neonatal ventilators", The Journal of pediatrics, 204, pp.157~161 (2019)[DOI]
  28. Lahav A, "An acoustic gap between the NICU and womb : A potential risk for compromised neuroplasticity of the auditory system in preterm infants", Frontiers in Neuroscience, 8, pp.381~ (2014)[DOI]
  29. Smith SW, "Noise in the neonatal intensive care unit : A new approach to examining acoustic events", Noise and Health, 20(95), pp.121~130 (2018)[DOI]
  30. White RD, "Committee to Establish Recommended Standards for Newborn ICU Design. Recommended standards for newborn ICU design, eighth edition", Journal of Perinatology, 33(Suppl 1), pp.S2~S16 (2013)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (16건)