A new disposable amperometric tri-enzyme biosensor for the detection of paracetamol has been developed. Theparacetamol sensors developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs)coupled with immobilized enzymes, tyrosinase and aryl acylamidase, prepared using a poly (vinyl alcohol) bearingparacetamol biosensor showed detection limit for paracetamol is as low as 100M and the sensitivity of the sensor is1.46 nAμM− ¹cm− ².
Abstract
A new disposable amperometric tri-enzyme biosensor for the detection of paracetamol has been developed. Theparacetamol sensors developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs)coupled with immobilized enzymes, tyrosinase and aryl acylamidase, prepared using a poly (vinyl alcohol) bearingparacetamol biosensor showed detection limit for paracetamol is as low as 100M and the sensitivity of the sensor is1.46 nAμM− ¹cm− ².
참고문헌 (20)
- P. Routledge, "Paracetamol (acetaminophen) poisoning-No need to change current guidelines to accident departments", British Medical Journal, 317, pp.1609~1610 (1998)
- A. Vale, "Paracetamol (acetaminophen)", Medicine, 35, pp.643~645 (2007)
- P. J. Zed, "Treatment of acetaminophen overdose", American J. of Health System Pharmacy, 56, pp.1081~1091 (1999)
- L. de Haro, "Accidental ingestion of paracetamol in the form of paediatric syrup (EFFERALGAN). Experience of marseille poison control centre in 1998", Therapie, 54, pp.771~773 (1999)
- E. Dinç, "Simultaneous spectrophotometric determination of mefenamic acid and paracetamol in a pharmaceutical preparation using ratio spectra derivative spectrophotometry and chemometric methods", J. Pharmaceutical and Biomedical Analysis, 28, pp.1091~1100 (2002)
- K. K. Verma, "Flowinjection spectroptometric determination of acetaminophen in drug formulations", Analytica Chimica Acta, 261, pp.261~267 (1992)
- A. Criado, "Continuous flow spectrophotometric determination of paracetamol in pharmaceuticals following continuous microwave assisted alkaline hydrolysis", Talanta, 53, pp.417~423 (2000)
- M. K. Srivastava, "Titrimetric determination of dipyrone and paracetamol with potassium hexacyanoferrate(III) in an acidic medium", Analyst, 110, pp.735~737 (1985)
- J. L. Vilchez, "Spectrofluorimetric determination of paracetamol in pharmaceuticals and biological fluids", J. Pharmaceutical and Biomedical Analysis, 13, pp.1119~1125 (1995)
- O. W. Lau, "Simultaneous determination of ascorbic acid, caffeine and paracetamol in drug formulations by differential- pulse voltammetry using a glassy carbonelectrode", Analyst, 114, pp.1047~1051 (1989)
- S. Ravisankar, "Reversed-phase HPLC method for the estimation of acetaminophen, ibuprofen and chlorzoxazone in formulations", Talanta, 46, pp.1577~1581 (1998)
- J. Roy, "Rapid screening of marketed paracetamol tablets: Use of thin-layer chromatography and a semiquantitative spot test", Bulletin of the World Health Organization, 75, pp.19~22 (1997)
- M. L. Ramos, "Determination of acetaminophen by flow injection with on-line chemical derivatization: Investigations using visible and FTIR spectrophotometry", Analytica Chimica Acta, 364, pp.107~116 (1998)
- G., F. Cespedes, "Sequential injection system with higher dimensional electrochemical sensor signals Part 1. Voltammetric e-tongue for the determination of oxidizable compounds", Talanta, 66, pp.1187~1196 (2005)
- G. A. Messina, "On-line microfluidic sensor integrated with an enzymemodified pre-cell for the monitoring of paracetamol in pharmaceutical samples", Analytica Chimica Acta, 559, pp.152~158 (2006)
- S. F. Wang, "Carbon-coated nickel magnetic nanoparticles modified electrodes as a sensor for determination of acetaminophen", Sensors and Actuators B-Chemical, 123, pp.495~500 (2007)
- F. W. Scheller, "Research and development in biosensors", Current Opinion in Biotechnology, 12, pp.35~40 (2001)
- Y. T. Lee, "Development of the disposable glucose sensor using Cu", Ni, J. Korean Sensors Society, pp.2006, 15(5)[DOI]
- S. C. Chang, "Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) Detection", J. Korean Sensors Society, 16(6), pp.449~456 (2007)
- S. C. Chang, "Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols", Biosensors & Bioelectronics, 17, pp.1015~1023 (2002)