U-헬스 센서 네트워크 시스템의 생체신호 압축 처리
Application of Biosignal Data Compression for u-Health Sensor Network System
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.
Abstract
A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.
참고문헌 (23)
- N. Baker, "ZigBee and Bluetooth strengths and weaknesses for industrial applications", Computer and Control Eng. J, 16(2), pp.20~25 (2005)
- D. A. Huffman, "A method for the construction of minimum-redundancy codes", Proc. of the IRE, 40(9), pp.1098~1101 (1952)
- P. G. Howard, "Arithmetic coding for data compression", Proc. of the IEEE, 82(6), pp.857~865 (1994)
- D. Pountain, "Run length encoding", Byte, 12(6), pp.317~320 (1987)
- J. Ziv, "A universal algorithm for sequential data compression", IEEE Trans. Information Theory, 23(3), pp.337~343 (1977)
- S.M. S. Jalaleddine, "ECG data compression techniques-A unified approach", IEEE Trans. Biomedical Eng, 37(4), pp.329~343 (1990)
- J. R. Cox, "AZTEC, a preprocessing program for real time ECG rhythm analysis", IEEE Trans. Biomedical Eng, BME-15(2), pp.128~129 (1968)
- J. P. Abenstein, "A new data reduction algorithm for real time ECG analysis", IEEE Trans. Biomedical Eng., BME-29(1), pp.43~48 (1982)
- W. C. Mueller, "Arrhythmia detection program for an ambulatory ECG monitor", Biomedical Sciences Instrumentation, 14, pp.81~85 (1978)
- V. A. Allen, "ECG data compression using the discrete cosine transform(DCT)", Proc. Computers in Cardiology 1992, pp.687~690 (1992)
- A. Djohan, "ECG compression using discrete symmetric wavelet transform", 1995 IEEE 17th Annual Conf. Eng. in Medicine and Biology Society, pp.167~168 (1995)
- B. R. Shankara Reddy, "ECG data compression using fourier descriptors", IEEE Trans. Biomedical Eng., BME-33(4), pp.428~434 (1986)
- J. G. Webster, "Medical Instrumentation : Application and Design, 4th Edition", pp.320~381 (2009), John Wiley & Sons
- J. H. McClellan, "Signal Processing First", pp.71~100 (2003), Pearson Education
- W. Shin, "ECG", PPG integer signal processing for a ubiquitous health monitoring system, 2010, pp.34(5), 891~898
- 윤길원, "Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare", JOURNAL OF MEDICAL SYSTEMS, 33(4), pp.261~266, SPRINGER
- 윤길원, "Ubiquitous Health Monitoring System for Multiple Users Using a ZigBee and WLAN Dual-Network", TELEMEDICINE JOURNAL AND E-HEALTH, 15(9), pp.891~897, MARY ANN LIEBERT INC
- F. Marvasti, "Efficient algorithms for burst error recovery using FFT and other transform kernels", IEEE Trans. Signal Processing, 47(4), pp.1065~1075 (1999)
- G. B. Moody, "impact of the MIT-BIH arrhythmia database", IEEE Eng. In Med. And Biol., 20(3), pp.45~50 (2001)
- L. V. Batista, "Compression of ECG signals by optimized quantization of discrete cosine transform coefficients", Medical Engineering and Physics, 23(2), pp.127~134 (2001)
- C. M. Fira, "An ECG signals compression method and its validation using NNS", IEEE Trans. Biomedical Eng., 55(4), pp.1319~1326 (2008)
- L. V. Batista, "Compression of ECG signals by optimized quantization of discrete cosine transform coefficients", Medical Engineering and Physics, 23(2), pp.127~134 (2001)
- D. A. Dipersio, "Evaluation of the fan method of adaptive sampling on human electrocardiograms", Medical and Biomedical and Eng. Computing, 23(5), pp.401~410 (1985)
