본문 바로가기
KERD
논문KCI 등재

경량화된 심전도 측정 임베디드 장비에서 템플릿 기반 직선근사화를 이용한 통신오버헤드 감소 기법

Communication-Power Overhead Reduction Method Using Template-Based Linear Approximation in Lightweight ECG Measurement Embedded Device

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

With the recent development of hardware and software technology, interest in the development of wearable devices is increasing. In particular, wearable devices require algorithms suitable for low-power and low-capacity embedded devices. Among them, there is an increasing demand for a signal compression algorithm that reduces communication overhead, in order to increase the efficiency of storage and transmission of electrocardiogram (ECG) signals requiring long-time measurement. Because normal beats occupy most of the signal with similar shapes, a high rate of signal compression is possible if normal beats are represented by a template. In this paper, we propose an algorithm for determining the normal beat template using the template cluster and Pearson similarity. Also, the template is expressed effectively as a few vertices through linear approximation algorithm. In experiment of Datum 234 of MIT-BIH arrhythmia database (MIT-BIH ADB) provided by Physionet, a compression ratio was 33.44:1, and an average distribution of root mean square error (RMSE) was 1.55%.

Abstract

With the recent development of hardware and software technology, interest in the development of wearable devices is increasing. In particular, wearable devices require algorithms suitable for low-power and low-capacity embedded devices. Among them, there is an increasing demand for a signal compression algorithm that reduces communication overhead, in order to increase the efficiency of storage and transmission of electrocardiogram (ECG) signals requiring long-time measurement. Because normal beats occupy most of the signal with similar shapes, a high rate of signal compression is possible if normal beats are represented by a template. In this paper, we propose an algorithm for determining the normal beat template using the template cluster and Pearson similarity. Also, the template is expressed effectively as a few vertices through linear approximation algorithm. In experiment of Datum 234 of MIT-BIH arrhythmia database (MIT-BIH ADB) provided by Physionet, a compression ratio was 33.44:1, and an average distribution of root mean square error (RMSE) was 1.55%.

참고문헌 (14)

  1. S. L. Rohit, "Iot Based Health Monitoring System Using Raspberry PI –Review", Second International Conference on Inventive Communication and Computational Technologies, pp.997~1002 (2018)
  2. Sid Ahmed Elhannachi, "Adaptive Medical Image Compression Based on Lossy and Lossless Embedded Zerotree Methods", JIPS(Journal of Information Processing Systems), 13(1), pp.40~56 (2017), 한국정보처리학회[DOI]
  3. 박용주, "생체 환경 정보 센싱 모듈 및 농장 제어 게이트웨이를 이용한 스마트 낙농 관리 시스템 개발", 대한임베디드공학회논문지, 11(1), pp.15~20 (2016), 대한임베디드공학회[DOI]
  4. 이형봉, "SpO2 기반 휴대형 생체 신호 모니터링 시스템 개발", 대한임베디드공학회논문지, 8(5), pp.273~283 (2013), 대한임베디드공학회[DOI]
  5. 이아라, "욕창 방지를 위한 체압 모니터링 시스템 개발", 대한임베디드공학회논문지, 6(4), pp.209~214 (2011), 대한임베디드공학회
  6. W. Smith, "Comparison of Diagnostic Value Using a Small, Single Channel, P-wave Centric Sternal ECG Monitoring Patch with a Standard 3-lead Holter System over 24 Hours", American Heart Journal, 185, pp.67~73 (2016)
  7. S. Lee, "Efficient Fiducial Point Detection of ECG QRS Complex Based on Polygonal Approximation", Sensors, 18(12), pp.1~16 (2018)
  8. S. Lee, "Advanced Real-Time Dynamic Programming in the Polygonal Approximation of ECG Signals for a Lightweight Embedded Device", IEEE Access, 7, pp.1628501~1162861 (2019)
  9. R. Bellman, "Applied Dynamic Programming" (2015), Princeton Legacy Library, Princeton University Press
  10. J. Ma, "A Novel ECG Data Compression Method Using Adaptive Fourier Decomposition With Security Guarantee in e-Health Applications", IEEE Journal of Biomedical and Health Informatics, 19(3), pp.986~994 (2015)
  11. X. Wang, "ECG Cmpression Based on Combining of EMD and Wavelet Transform", Electronics Letters, 52(19), pp.1588~1590 (2016)
  12. G. Bansal, "Template Based Classification of Cardiac Arrhythmia in ECG Data", 2015 IEEE 2nd International Conference on Recent Trends in Information Systems, pp.337~341 (2015)
  13. S. M. Lee, "Self-Organized Real-Time Authentication Mechanism Using ECG Signal", 2014 The International Industrial Information Systems Conference, pp.231~233 (2014)
  14. G. B. Moody, "The MIT-BIH Arrhythmia Database on CD-ROM and Software for Use with it", Proceedings Computers in Cardiology, pp.185~188 (1990)

관련 논문AI추천

이 간행물의 다른 논문 (6건)