본문 바로가기
KERD
논문KCI 등재

단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from 10-1 to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

Abstract

We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from 10-1 to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

참고문헌 (16)

  1. M. J. Schoning, "Recent advances in biologically sensitive field-effect transistors (BioFETs)", The Analyst, 127, pp.1137~1151 (2002)
  2. B. A. Cornell, "A biosensor that uses ion-chnannel switches", Nature, 387, pp.580~583 (1997)
  3. A. Poghossian, "Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method", Sens. Actuator BChem, 103, pp.423~428 (2004)
  4. T. M. Pan, "A TiO2", Er2O3 stacked electrolyte, semiconductor film pH-sensor for the detection of urea, pp.Sens. Actuator B-Chem, 2009[DOI]
  5. H.-J. Jang, "Improved sensing performance of polycrystalline silicon base dual-gate ion-sensitive field-effect transistors using high-k stacking engineered sensing membrane", Applied Physics Letters, 100(253703), pp.1~4 (2012)
  6. J. C. Chou, "Sensitivity and hysteresis effect in Al2O3 gate pH-ISFET", Materials Chemistry and Physics, 71, pp.120~124 (2001)
  7. T. F. Lu, "Non-ideal effects improvement of SF6 plasma treated hafnium oxide film based on electrolyte-insulator-semiconductor structure for pH-sensor application", Microelectronics Reliability, 50, pp.742~746 (2010)
  8. T. M. Pan, "Study of high-k Er2O3 thin layers as ISFET sensitive insulator surface for pH detection", Sens. Actuator BChem, 138, pp.619~624 (2009)
  9. S. P. Tiwari, "Low-voltage solution-processed nchannel organic field-effect transistors with high-k HfO2 gate dielectrics grown by atomic layer deposition", Applied Physics Letters, 95(223303), pp.1~3 (2009)
  10. J. Y. Oh, "Highly sensitive electrolyte-insulator-semiconductor pH sensors enabled by silicon nanowires with Al2O3", SiO2 sensing membrane, 2012, pp.171, 238~243
  11. H. J. Jang, "Fabrication of high performance ion-sensitive field-effect-transistors using an engineered sensing membrane for biosensor application", Jpn. J. Appl. Phys, 51(02BL05), pp.1~4 (2012)
  12. S.-J. Seo, "High performance solution-processed amorphous zinc tin oxide thin film transistor", J. Phys. D: Appl. Phys, 42(035106), pp.1~5 (2008)
  13. L. Setti, "An HRP-based amperometric biosensor fabricated by thermal inkjet printing", Sens. Actuator B-Chem, 126, pp.252~257 (2007)
  14. Y. B. Yoo, "Low-Temperature, Solution-Processed Zinc Tin Oxide Thin-Film Transistors Fabricated by Thermal Annealing and Microwave Irradiation", JAPANESE JOURNAL OF APPLIED PHYSICS, 51(4), pp.1~3 (2012), JAPAN SOC APPLIED PHYSICS
  15. W. Y. Lin, "Room-temperature solution-processed high-k gate dielectrics for large area electronics applications", Organic Electronics, 12, pp.955~960 (2011)
  16. C. E. Lue, "Hysteresis effect on traps of Si3N4 sensing membranes for pH difference sensitivity", Microelectron. Reliability, 50, pp.738~741 (2010)

관련 논문AI추천

플라스틱 광섬유 센서를 이용한 핵 연료의 열중성자 분포도 측정김신, 문주현, 박병기, 서정기, 유욱재, 이봉수, 장경원, 조동현, 조영호, 허지연한국센서학회 · 센서학회지2009 · 제18권 제5호252Cf 선원을 이용한 즉발감마선 계측시스템 구성박용준, 송병철, 지광용한국분석과학회 · 분석과학2003 · 제16권 제1호Neutron dosimetry with a pair of TLDs for the Elekta Precise medical linac and the evaluation of optimum moderator thickness for the conversion of fast to thermal neutrons미트라게게르치, Bahreyni Toossi Mohammad Taghi, Behmadi Marziyeh, Loushab Mahdy Ebrahimi, Mohammadi Aghil, Mohammadi Sara, Ravari Mohammad Ehsan한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제2호조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가김성환, 김홍주, 천종규한국센서학회 · 센서학회지2014 · 제23권 제1호마이크로 도시메트리용 다분할 조직등가비례계수기의 개발과 특성 평가김성환, 남욱원, 문명국, 문봉곤, 박원기, 이수현, 이재진, 임창휘, 표정현한국센서학회 · 센서학회지2015 · 제24권 제2호Method of the known cross sections for calibration of the fast neutron spectrometer with a single-crystal stilbene based detectorIbragimov R.F., Ryabeva E.V., Sapozhnikov V.D., Urupa I.V.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호

이 간행물의 다른 논문 (11건)