초록
We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from 10-1 to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.
Abstract
We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from 10-1 to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.
참고문헌 (16)
- M. J. Schoning, "Recent advances in biologically sensitive field-effect transistors (BioFETs)", The Analyst, 127, pp.1137~1151 (2002)
- B. A. Cornell, "A biosensor that uses ion-chnannel switches", Nature, 387, pp.580~583 (1997)
- A. Poghossian, "Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method", Sens. Actuator BChem, 103, pp.423~428 (2004)
- T. M. Pan, "A TiO2", Er2O3 stacked electrolyte, semiconductor film pH-sensor for the detection of urea, pp.Sens. Actuator B-Chem, 2009[DOI]
- H.-J. Jang, "Improved sensing performance of polycrystalline silicon base dual-gate ion-sensitive field-effect transistors using high-k stacking engineered sensing membrane", Applied Physics Letters, 100(253703), pp.1~4 (2012)
- J. C. Chou, "Sensitivity and hysteresis effect in Al2O3 gate pH-ISFET", Materials Chemistry and Physics, 71, pp.120~124 (2001)
- T. F. Lu, "Non-ideal effects improvement of SF6 plasma treated hafnium oxide film based on electrolyte-insulator-semiconductor structure for pH-sensor application", Microelectronics Reliability, 50, pp.742~746 (2010)
- T. M. Pan, "Study of high-k Er2O3 thin layers as ISFET sensitive insulator surface for pH detection", Sens. Actuator BChem, 138, pp.619~624 (2009)
- S. P. Tiwari, "Low-voltage solution-processed nchannel organic field-effect transistors with high-k HfO2 gate dielectrics grown by atomic layer deposition", Applied Physics Letters, 95(223303), pp.1~3 (2009)
- J. Y. Oh, "Highly sensitive electrolyte-insulator-semiconductor pH sensors enabled by silicon nanowires with Al2O3", SiO2 sensing membrane, 2012, pp.171, 238~243
- H. J. Jang, "Fabrication of high performance ion-sensitive field-effect-transistors using an engineered sensing membrane for biosensor application", Jpn. J. Appl. Phys, 51(02BL05), pp.1~4 (2012)
- S.-J. Seo, "High performance solution-processed amorphous zinc tin oxide thin film transistor", J. Phys. D: Appl. Phys, 42(035106), pp.1~5 (2008)
- L. Setti, "An HRP-based amperometric biosensor fabricated by thermal inkjet printing", Sens. Actuator B-Chem, 126, pp.252~257 (2007)
- Y. B. Yoo, "Low-Temperature, Solution-Processed Zinc Tin Oxide Thin-Film Transistors Fabricated by Thermal Annealing and Microwave Irradiation", JAPANESE JOURNAL OF APPLIED PHYSICS, 51(4), pp.1~3 (2012), JAPAN SOC APPLIED PHYSICS
- W. Y. Lin, "Room-temperature solution-processed high-k gate dielectrics for large area electronics applications", Organic Electronics, 12, pp.955~960 (2011)
- C. E. Lue, "Hysteresis effect on traps of Si3N4 sensing membranes for pH difference sensitivity", Microelectron. Reliability, 50, pp.738~741 (2010)