본문 바로가기
KERD
논문KCI 등재

플라스틱 광섬유 센서를 이용한 핵 연료의 열중성자 분포도 측정

Measurements of thermal neutron distribution of nuclear fuel using a plastic fiber-optic sensor

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류공학일반

초록

In this study, plastic optical fiber sensors which can measure thermal neutron dose in a mixed neutron-gamma field are developed and characterized. Using 252Cf and 60Co sources, the scintillators suitable for thermal neutron etection, are tested and the scintillating lights generated from a plastic optical fiber sensor in the Kyoto University Critical Assembly (kuca) core are measured. Also, the distributions of thermal neutron and gamma-ray are measured in a mixed field as a function of the distance from the center of the reactor core at KUCA and the distribution of thermal neutron is obtained using a subtraction method. Sensitivity of the fiber-optic radiation sensor system is about 0.49 V/mW according to power of the KUCA core and its relative error is about 1.2 %.

Abstract

In this study, plastic optical fiber sensors which can measure thermal neutron dose in a mixed neutron-gamma field are developed and characterized. Using 252Cf and 60Co sources, the scintillators suitable for thermal neutron etection, are tested and the scintillating lights generated from a plastic optical fiber sensor in the Kyoto University Critical Assembly (kuca) core are measured. Also, the distributions of thermal neutron and gamma-ray are measured in a mixed field as a function of the distance from the center of the reactor core at KUCA and the distribution of thermal neutron is obtained using a subtraction method. Sensitivity of the fiber-optic radiation sensor system is about 0.49 V/mW according to power of the KUCA core and its relative error is about 1.2 %.

참고문헌 (12)

  1. N. Tsoufanidis, "Measurement and detection of radiation", pp.423~ (1983), McGraw-Hill
  2. Y. Yamane, "Measurement of 14.1 MeV neutrons with a Th-scintillator optical fibre detector", Nucl. Instrum. Phys. Res. A, 416, pp.371~380 (1998)
  3. C. Mori, "Measurement of neutron and γ-ray intensity distributions with an optical fiber-scintillator detector", Nucl. Instrum. Phys. Res. A, 422, pp.129~132 (1999)
  4. Y. Yamane, "Measurement of the thermal and fast neutron flux in a research reactor with a Li and Th loaded optical fibre detector", Nucl. Instrum. Phys. Res. A., 432, pp.403~409 (1999)
  5. A. S. Beddar, "Plastic scintillation dosimetry and its application to radiotherapy", Radi. Meas., 41, pp.S124~S133 (2007)
  6. B. Lee, "Measure- -ments and elimination of cherenkov light in fiberoptic scintillating detector for electron beam therapy dosimetry", Nucl. Instrum. Phys. Res. A., 579, pp.344~348 (2007)
  7. A. S. Beddar, "A miniature ‘Scintillator-Fiberoptic-PMT’ detector system for the dosimetry of small fields in stereotactic radiosurgery", IEEE Trans. Nucl. Sci., 48, pp.924~928 (2001)
  8. M. R. Arnfield, "Radiation-induced light in optical fibers and plastic scintillators : Application to brachytherapy dosimetry", IEEE Trans. Nucl. Sci., 43, pp.2077~2084 (1996)
  9. A. S. Beddar, "Plastic scintillation dosimetry: optimaza-- tion of light collection efficiency", Phys. Med. Biol., 48, pp.1141~1152 (2003)
  10. B. Lee, "Polymerpolymer miscibility study for plastic gradient index optical fiber", Polymer Eng. and Sci., 40(9), pp.1996~1999 (2000)
  11. 유욱재, "적외선 투과 광섬유를 이용한 고주파 열치료 과정에서의 온도분포 측정", 센서학회지, 17(6), pp.397~405 (2008), 한국센서학회
  12. 신상훈, "유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의상대 깊이 선량율 측정", 센서학회지, 17(6), pp.462~469 (2008), 한국센서학회

관련 논문AI추천