Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS
2
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of 80 was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human’s popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was slightly larger than at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were 1664.14 Ω and 1614.08 Ω, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane
Abstract
Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of 80 was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human’s popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was slightly larger than at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were 1664.14 Ω and 1614.08 Ω, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane
참고문헌 (21)
- H. C Lukaski, "Methods for the assessment of human body composition : traditional and new", The American journal of clinical nutrition, 46, pp.537~556 (1987)
- B. E Lingwood, "Biomedical applications of electrical impedance analysis", Proc. Of ISSAP, 1, pp.367~330 (1999)
- L. C. Ward, "Segmental bioelectrical impedance analysis an update", Lippincott Williams & Wilkins, 15(5), pp.424~429 (2012)
- H. C. Lukaski, "Biological indexes considered in the derivation of the bioelectrical impedance analysis", The American journal of clinical nutrition, 64(3), pp.397~404 (1996)
- G. McNeill, "Body fat in lean and overweight women estimated by six methods", Br. J. Nutr, 65(2), pp.95~103 (1991)
- P. Deurenberg, "Multi-frequency impedance for the prediction of extracellular water and total body water", Br. J. Nutr, 73(3), pp.349~358 (1995)
- R. F. Kushner, "Estimation of total body water by bioelectrical impedance analysis", Am. J. Clin. Nutr, 44, pp.417~424 (1986)
- H. Kanai, "Electrical measurement of fluid distribution in legs and arms", Medical progress through technology, 12, pp.159~170 (1987)
- D. Dumler, "A low bioimpedance phase angle predicts a higher mortality and lower nutritional status in chronic dialysis patients", J. Phys.: Conf. Ser, 224, pp.012104~[DOI]
- S. Kumar, "Phase angle measurement in healthy human subjects through bio-impedance analysis", Iran J Basic Med Sci., 15(6), pp.1180~1184 (2012)
- 김재형, "Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method", 센서학회지, 23(6), pp.368~376 (2014), 한국센서학회[DOI]
- A. De Lorenzo, "Improved prediction formula for total body water assessment in obese women", International J. of obesity and related metabolic disorders, pp.535~538 (1995)
- R. K. Wangsness, "Electromagnetic fields", pp.455~456 (1986), John Wiley & Sons Inc.
- P. P. Urone, "College Physic", pp.2001, BROOKS
- H. D. Young, "University Physics", pp.1064~1074 (2008), Addison Wesley
- K. S. Cole, "Dispersion and absorption in dielectrics : I. alternating current characteristics", Journal of chemical physics, 9, pp.341~351 (1936)
- H. C. Lukaski, "Assessment of fat-free mass using bioelectrical impedance measurements of the human body", Am. J. of Clin. Nutr, 41, pp.810~817 (1985)
- K. Norman, "Bioelectrical phase angle and impedance vector analysis e Clinical relevance and applicability of impedance parameters", Clinical Nutrition, 31, pp.854~861 (2012)
- B. Nordbotten, "Evaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus", Physiol. Meas, 32(7), pp.755~765 (2011)
- M. S. Mialich, "Analysis of body composition : A critical review of the use of bioelectrical impedance analysis", International Journal of Clinical Nutrition, 2(1), pp.1~10 (2014)
- B. H. Cornish, "Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis", Phys. Med. Biol, 38, pp.337~346 (1993)