Comparison of Infiltration Induced in Veins of Rabbit’s Ear and Human’s Forearm by Using Bioelectrical Impedance: Pilot Study

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류공학일반

초록

An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltrationat puncture sites. When infiltration was intentionally induced in the vein of a rabbit’s ear, impedance parameters showed significant dif-ference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit’s ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltratedintravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein ofa human’s forearm, the relative resistance at 20 kHz decreased gradually over time. In the R–X graph, the positions in infiltrationinduced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human’s forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infil- tration early in a noninvasive and quantitative manners.

Abstract

An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltrationat puncture sites. When infiltration was intentionally induced in the vein of a rabbit’s ear, impedance parameters showed significant dif-ference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit’s ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltratedintravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein ofa human’s forearm, the relative resistance at 20 kHz decreased gradually over time. In the R–X graph, the positions in infiltrationinduced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human’s forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infil- tration early in a noninvasive and quantitative manners.

참고문헌 (26)

  1. C. M. Rickard, "Routine versus clinically indicated replacement of peripheral intravenous catheters : A randomised controlled equivalence trial", Lancet, 380, pp.1066~1074 (2012)
  2. Infusion Nurses Society, "Infusion Nursing Standards of Practice", Journal of Infusion Nursing, 29, pp.S91~S92 (2006)
  3. L. Hadaway, "Infiltration and extravasation", American Journal of Nursery, 107, pp.64~72 (2007)
  4. M. Oya, "Low-temperature infiltration identified using infrared thermography in patients with subcutaneous edema revealed ultrasonographically : A case report", Drug Discoveries & Therapeutics, 10(2), pp.117~122 (2016)
  5. L. Dougherty, "IV therapy : recognizing the differences between infiltration and extravasation", British Journal of Nursing, 17(14), pp.896~901 (2008)
  6. "Complications of Peripheral I.V. Therapy" (2015)[URL]
  7. L. Hadaway, "Infiltration and extravasation", American Journal of Nursery, 107(8), pp.64~72 (2007)
  8. L. Hadaway, "Protect patients from I.V. infiltration", American Nurse Today, 5(2) (2010)
  9. D. Doellman, "Infiltration and extravasation : update on prevention and management", Journal of Infusion Nursing, 32(4), pp.203~211 (2009)
  10. J. A. Jambulingam, "Noninvasive, multi-modal sensing of skin stretch and bioimpedance for detecting infiltration during intravenous therapy", Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference, pp.16~20 (2016)
  11. Wintec, LLC., "Optical detection of intravenous infiltration", US 7,826,890 B1, ~ (2005)
  12. "An optical device for detecting intravenous infiltration" (2006)[URL]
  13. "Ultrasound Detection of Peripheral IV Infiltration" (2013)[URL]
  14. U. G. Kyle, "Bioelectrical impedance analysis-part 1 : review of principles and methods", Clinical Nutrition, 23(5), pp.1226~1243 (2004)
  15. S. F. Kalil, "The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases", Sensors, 14, pp.10895~10928 (2014)[DOI]
  16. S. Berlit, "Whole-body versus segmental bioelectrical impedance analysis in patients with edema of the upper limb after breast cancer treatment", Anticancer Research, 33(8), pp.3403~3406 (2013)
  17. R. Buffa, "Bioelectrical impedance vector analysis(BIVA)for the assessment of two-compartment body composition", European Journal Clinical Nutrition, 68(11), pp.1234~1240 (2014)
  18. I. S. Grimnes, "Martinsen, Bioimpedance and bioelectricity basics" (2015), Academic Press
  19. S. F. Khalil, "The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases", Sensors, 14(6), pp.10895~10928 (2014)
  20. P. P. Urone, "College Physics", pp.2001, Brooks
  21. E. Mazzaferro, "Fluid therapy for the emergent small animal patient : crystalloids, colloids, and albumin products", Veterinary Clinics of North America : Small Animal Practice, 43(4), pp.721~734 (2013)
  22. F. Zhu, "Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis", Physiological Measurement, 26(2), pp.S133~S143 (2005)
  23. 전계록, "Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS", 센서학회지, 25(1), pp.1~7 (2016), 한국센서학회
  24. E. Hernandez-Balagueraa, "Obtaining electrical equivalent circuits of biological tissues using the current interruption method, circuit theory and fractional calculus", Royal Society of Chemistry, 6, pp.22312~22319 (2016)
  25. B. C. Kim, "Multi-channel impedance measuring method and multi-channel impedance measuring instrument", WO 2014, KR2013, pp.005779, 2013[DOI]
  26. 김재형, "Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study", 센서학회지, 26(1), pp.15~23 (2017), 한국센서학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (11건)