In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.
Abstract
In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.
참고문헌 (15)
- K. K. F. Tsoi, "Cost-effectiveness analysis on screening for colorectal neoplasm and management of colorectal cancer in Asia", Aliment Pharmacol Ther., 28(3), pp.353~363 (2008)
- R. E. Ley, "Human gut microbes associated with obesity", Nature, 444, pp.1022~1023 (2006)
- A. Vrieze, "The environment within how gut microbiota may influence metabolism and body composition", Diabetologia, 53(4), pp.606~613 (2010)
- D. Monleón, "Metabolite profiling of fecal water extracts from human colorectal cancer", J. NMR Biomed., 22(3), pp.342~348 (2008)
- J. R. Marchesi, "Rapid and noninvasive metabonomic characterization of inflammatory bowel disease", J. Proteome Res., 6(2), pp.546~551 (2007)
- P. Louis, "Diversity, metabolism and microbial ecology of butyrate-producing bacteria from the human large intestine", FEMS Microbiol. Lett., 294(1), pp.1~8 (2009)
- S. W. Brooks, "Canine olfaction and electronic nose detection of volatile organic compounds in the detection of cancer : a review", Cancer Invest., 33(9), pp.411~419 (2015)
- N. Neumann, "Tunnable infrared detector with integrated micromachined Fabry-Perot filter", J. Micro, 2008, pp.7(2), 021004(1)~021004(13)
- E. Hecht, "Optics, 1 Lake St", pp.409~418 (1998), Addison-Wesley Longman
- J. H. Jerman, "A miniature Fabry-Perot interferometer with a corrugated silicon diaphragm support", Sens. Actuators A, 29, pp.151~158 (1991)
- H. J. No, "Principal component analysis & factor analysis", pp.4~109 (2014), Hanol
- H. J. No, "Principle of multivariable analysis and exercises using Excel and SPSS", pp.397~412 (2010), Hanol
- W. Filipiak, "A compendium of volatile organic compounds(VOCs)released by human cell lines", Curr. Med. Chem., 23(20), pp.2112~2131 (2016)
- SeungHwan Yi, "광학식 전자코에 의한 생체표지자 분석", 센서학회지, 28(3), pp.171~176 (2019), 한국센서학회