SAW 센서의 제작 및 독성화학물질 감도특성 연구
A study on the fabrication of polymer-coated SAW sensors and their sensing properties for some toxic chemical compounds
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Polymer-coated film SAW sensors have been fabricated and their sensing properties for toxic chemicals have been extensively investigated. Four types of the toxic chemical compounds of hydrogen cyanide(AC), carbonyl dichloride(CG), pinacolyl methylfluorophosphonate(GD), 2,2’-dichlorodiethylthio ether(HD) were used as target gases. SAW sensors using five different kinds of polymers were used to detect toxic chemicals and their gas sensing characteristics were investigated. The polymers used as the sensing materials were polyisobutylene(PIB), polyepichlorohydrin( PECH), polydimethylsiloxane(PDMS), polybutadiene(PBD) and polyisoprene(PIP). The recommendable mixing ratio of PIB, PECH, PDMS, PBD and PIP to solvents were 1 : 30, 1 : 40, 1 : 10, 1 : 30 and 1 : 30, respectively. The sensing characteristics of the SAW sensors were measured by using E-5061A network analyzer
Abstract
Polymer-coated film SAW sensors have been fabricated and their sensing properties for toxic chemicals have been extensively investigated. Four types of the toxic chemical compounds of hydrogen cyanide(AC), carbonyl dichloride(CG), pinacolyl methylfluorophosphonate(GD), 2,2’-dichlorodiethylthio ether(HD) were used as target gases. SAW sensors using five different kinds of polymers were used to detect toxic chemicals and their gas sensing characteristics were investigated. The polymers used as the sensing materials were polyisobutylene(PIB), polyepichlorohydrin( PECH), polydimethylsiloxane(PDMS), polybutadiene(PBD) and polyisoprene(PIP). The recommendable mixing ratio of PIB, PECH, PDMS, PBD and PIP to solvents were 1 : 30, 1 : 40, 1 : 10, 1 : 30 and 1 : 30, respectively. The sensing characteristics of the SAW sensors were measured by using E-5061A network analyzer
참고문헌 (9)
- T. C. Marrs, "Chemical warfare agents : toxicology and treatment" (1996), John Wiley & Sons, New York
- M. To1chigi, "Serum cholesterol, uric acid and cholinesterase in victims of the Tokyo subway sarin poisoning: A relation with post-traumatic stress disorder", Neuroscience Research, 44(3), pp.267~272 (2002)
- A. Iwanami, "Mental symptomsin victims of sarin poisoning 5 years after the Tokyo subway attack", European Psychiatry, 17(1), pp.199~ (2002)
- Rayleigh, J.W.S, "On waves propagated along the plane surface of an elastic solid", Proc. London Math. Soc, 17, pp.4~11 (1885)
- R.M. White, "Direct piezoelectric coupling to surface electric waves", Appl. Phys. Lett, 7, pp.314~316 (1965)
- H. Wohltjen, "Mechanism of operation and design considerations for surface acoustic wave device vapor sensors", Sensors and Actuators, 5, pp.307~325 (1984)
- H. Wohljen, "Surface acoustic wave probe for chemical analysis. II. Gas chromatography detector", Analytical Chemistry, 51(9), pp.1465~1470 (1979)
- H. Wohljen, "Surface acoustic wave probe for chemical analysis. III. Thermomechanical polymer analyzer", Analytical Chemistry, 51(9), pp.1470~1475 (1979)
- 이은우, "화학작용제 검지용 SAW센서의 제작 및 특 성", 석사, 전자공학과, pp.2005
