본문 바로가기
KERD
논문KCI 등재

Eu 도핑 SrAl2O4 형광체의 광 여기 전류 특성에 대한 Dy 코-도핑 효과

Dy co-doping effect on photo-induced current properties of Eu-doped SrAl2O4 phosphor

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

Eu2+-doped SrAl2O4 and Eu2+Eu, Dy3+ co-doped SrAl2O4 phosphors have been synthesized by conventional solid state method. Photocurrent properties of Eu2+ doped SrAl2O4 and Eu2+, Dy3+ co-doped SrAl2O4 phosphors, in order to elucidate Dy3+ co-doping effect, during and after ceasing ultraviolet-ray (UV) irradiation have been investigated. The photocurrent of Eu2+, Dy3+ co-doped SrAl2O4 phosphors during UV irradiation was 4-times lower than that of Eu2+-doped SrAl2O4 during UV irradiation, and 7-times higher than that of Eu2+-doped SrAl2O4 after ceasing UV irradiation. The photocurrent results indicated that holes of charge carriers captured in hole trapping center during the UV irradiation and liberated after- glow process, and made clear that Dy3+ of co-dopant acted as a hole trap. The photocurrent of SrAl2O4 showed a good proportional relationship to UV intensity in the range of 1~ 5 mW/㎠, and Eu2+-doped SrAl2O4 was confirmed to be a possible UV sensor.

Abstract

Eu2+-doped SrAl2O4 and Eu2+Eu, Dy3+ co-doped SrAl2O4 phosphors have been synthesized by conventional solid state method. Photocurrent properties of Eu2+ doped SrAl2O4 and Eu2+, Dy3+ co-doped SrAl2O4 phosphors, in order to elucidate Dy3+ co-doping effect, during and after ceasing ultraviolet-ray (UV) irradiation have been investigated. The photocurrent of Eu2+, Dy3+ co-doped SrAl2O4 phosphors during UV irradiation was 4-times lower than that of Eu2+-doped SrAl2O4 during UV irradiation, and 7-times higher than that of Eu2+-doped SrAl2O4 after ceasing UV irradiation. The photocurrent results indicated that holes of charge carriers captured in hole trapping center during the UV irradiation and liberated after- glow process, and made clear that Dy3+ of co-dopant acted as a hole trap. The photocurrent of SrAl2O4 showed a good proportional relationship to UV intensity in the range of 1~ 5 mW/㎠, and Eu2+-doped SrAl2O4 was confirmed to be a possible UV sensor.

참고문헌 (19)

  1. L.-S. Jang, "Microfluidic device for cell capture and impedance measurement", Biomed. Microdevice, 9, pp.737~743 (2007)
  2. S. Zheung, "Micro coulter counters with platinum black electroplated electrodes for human blood cell sensing", Biomed. Microdevices, 10, pp.221~231 (2008)
  3. L.-M. Fu, "Fabrication and testing of high-performance detection sensor for capillary electrophoresis microchip", Biomed. Microdevices, 10, pp.73~80 (2008)
  4. S. Gawad, "Dielectric spectroscopy in a micromachined flow cytometer : Theoretical and practical considerations", Lab Chip, 4, pp.241~251 (2004)
  5. T. Sun, "Broadband single cell impedance spectroscopy using maximum length sequences : theoretical analysis and practical considerations", Meas. Sci. Technol., 18, pp.2859~2868 (2007)
  6. R. Pantoja, "Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics", Biosens. Bioelectron., 20(3), pp.509~517 (2004)
  7. N. Fertig, "Activity of single ion channel proteins detected with a planar microstructure", Appl. Phys. Lett., 9(25), pp.4865~4867 (2002)
  8. T. Lehnert, "Realization of hollow SiO2 micronozzles for electrical measurements of living cells", Appl. Phys. Lett., 81(26), pp.5063~5065 (2002)
  9. J. Seo, "Integrated multiple patch-clamp array chip via lateral cell trapping junctions", Appl. Phys. Lett., 84(11), pp.1973~1975 (2004)
  10. A. Y. Lau, "Open-access microfluidic patch-clamp array with raised lateral cell trapping sites", Lab Chip, 6, pp.1510~1515 (2006)
  11. C. Chen, "A high-performance elastomeric patch clamp chip", Lab Chip, 6, pp.1338~1345 (2006)
  12. E. Evans, "Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration", Biophys. J., 56, pp.151~160 (1989)
  13. M. Dao, "Mechanics of the human red blood cell deformed by optical tweezers", J. Mech. Phys. Solids., 51, pp.2259~2280 (2003)
  14. J. P. Mills, "Nonlinear elastic and viscoelastic deformation of the red blood cell induced by optical tweezers", Mech. Chem. Biosyst., 1, pp.169~180 (2004)
  15. S. Suresh, "Biomechanics and biophysics of cancer cells", Acta Biomater., 3, pp.413~438 (2007)
  16. 정귀상, "PDMS 몰드를 이용한 초고온 MEMS용 SiCN 미세구조물 제작과 그 특성", 센서학회지, 15(1), pp.53~57 (2006), 한국센서학회
  17. 윤광석, "미소유체 칩 상에서 Quantum Dot 및 마이크로 비드를 이용한 생체물질 분석", 센서학회지, 14(5), pp.308~312 (2005), 한국센서학회
  18. J. Guck, "Optical deformability as an inherent cell marker for testing malignant transformation and metastatic competence", Biophys. J., 88, pp.3689~3698 (2005)
  19. H. Morgen, "Single cell dielectric spectroscopy", J. Phys. D: Appl. Phys, 40, pp.61~70 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (11건)