A multilevel acoustic Fresnel lens (MAFL) for the ultrasonic imaging transducer of which center frequency is approximately 5 MHz was newly designed and fabricated. The phase level of the lens was 64, and the focal length and the aperture width were 30 mm and 11 mm, respectively. The characteristics of impulse response, acoustic field and imaging performance of the transducer attached the lens were compared with the transducer attached a conventional refraction type acoustic lens (RAL). The results show that the center frequency, the loop sensitivity, and the focal depth of the MAFL transducer were higher or larger than those of the RAL transducer by approximately 0.2 MHz, 1.4 dB, and 2 mm, respectively. Consequently, it was shown that the brighter acoustic images with higher lateral resolution and theincreased imaging performance for deep targets can be obtained by using the MAFL transducer.

Abstract

A multilevel acoustic Fresnel lens (MAFL) for the ultrasonic imaging transducer of which center frequency is approximately 5 MHz was newly designed and fabricated. The phase level of the lens was 64, and the focal length and the aperture width were 30 mm and 11 mm, respectively. The characteristics of impulse response, acoustic field and imaging performance of the transducer attached the lens were compared with the transducer attached a conventional refraction type acoustic lens (RAL). The results show that the center frequency, the loop sensitivity, and the focal depth of the MAFL transducer were higher or larger than those of the RAL transducer by approximately 0.2 MHz, 1.4 dB, and 2 mm, respectively. Consequently, it was shown that the brighter acoustic images with higher lateral resolution and theincreased imaging performance for deep targets can be obtained by using the MAFL transducer.

참고문헌 (16)

  1. G. Kino, "Acoustic Waves-Devices, Imaging and Analog Processing", pp.182~210 (1987), Prentice-Hall Inc.
  2. S. Farnow, "Acoustic applications of the zone plate", 박사, pp.1975
  3. B. Noorbehesht, "ResFigolution of Fresnel phase plate transducers", IEEE Ultrasonics Symposium Proceedings, pp.699~704 (1981)
  4. K. Yamada, "Planar-structure focusing lens for acoustic microscope", IEEE Ultrasonics Symposium Proceedings, pp.755~758 (1985)
  5. M. Sleva, "Design and construction of a PVDF Fresnel lens", IEEE Ultrasonics Symposium Proceedings, pp.821~826 (1990)
  6. B. Hadimioglu, "High-efficiency Fresnel acoustic lenses", IEEE Ultrasonics Symposium Proceedings, pp.579~582 (1993)
  7. S. Chan, "Finite element analysis of multilevel acoustic Fresnel lenses", IEEE Trans. on UFFC, 43(4), pp.670~677 (1996)
  8. K. Mori, "Numerical analysis of sound pressure fields focused by phase continuous Fresnel lens using finite difference time domain method", Jpn. J. Appl. Phys., 46, pp.4990~4997 (2007)
  9. Y. Sato, "Design for an aspherical acoustic Fresnel lens with phase continuity", Jpn. J. Appl. Phys., 47, pp.4354~4359 (2008)
  10. D. T. Blackstock, "Fundamentals of physical acoustics", John Wiley & Sons, pp.441~457 (2000)
  11. B. Piwakowski, "A new approach to calculate the field radiated from arbitrarily structured transducer arrays", IEEE Trans. on UFFC, 46(2), pp.422~440 (1999)
  12. T. Xue, "Numerical analysis of the radiated fields of circular pistons and time-delay spherically focused arrays", IEEE Trans. on UFFC, 43(1), pp.78~87 (1996)
  13. 조영환, "超音波 映像 診斷器用 變換器의 設計 및 過 渡音場 解析", 박사, pp.1995
  14. V. Ristic, "Principles of acoustic devices", pp.330~332 (1983), John Wiley & Sons, Inc
  15. N. M. Gibson, "A computerized quality control testing system for B-mode ultrasound", Ultrasound in Med & Biol., 27(12), pp.1697~1711 (2001)
  16. 강관석, "초음파 프로브의 성능에 따른 B-모드 영상의 질 평가", 석사, pp.2005