화학 가스센서를 활용한 구취측정 방법에 관한 연구
A Study on the Measurement of Halitosis of Human Mouth with Chemical Gas Sensor Arrays
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
This study was carried out to apply chemical gas sensors for the identification of bad breath which is one of the important sensitive problem for the humans' daily life. Seven sensors, including five semiconductor sensors and two electrochemical sensors, were tested for the three panels three times in several conditions. The results showed that the reproducibility of sensors were generally good, and electrochemical sensors showed better reproducibility while semiconductor sensors showed better sensitivity. No rinsing before measurement showed relatively better results in terms of both sensitivity and reproducibility. Semiconductor gas sensors for hydrogen sulfide shows the highest sensitivity, and it was recommended to use the odor-free bag for the measurement of bad breath.
Abstract
This study was carried out to apply chemical gas sensors for the identification of bad breath which is one of the important sensitive problem for the humans' daily life. Seven sensors, including five semiconductor sensors and two electrochemical sensors, were tested for the three panels three times in several conditions. The results showed that the reproducibility of sensors were generally good, and electrochemical sensors showed better reproducibility while semiconductor sensors showed better sensitivity. No rinsing before measurement showed relatively better results in terms of both sensitivity and reproducibility. Semiconductor gas sensors for hydrogen sulfide shows the highest sensitivity, and it was recommended to use the odor-free bag for the measurement of bad breath.
참고문헌 (18)
- Jung Pyo Hong, "Special edition:Halitosis", The Journal of Kyung Hee University Medical Center, 6(1), pp.4~8 (2000)
- Young Ku Kim, "Oral maoldor" (2008), Shinhung International Inc
- Il Hwan Choi, "The study on the fabrication and sensing characteristics of semiconductor gas sensor array for the electronic nose system", 석사, pp.2006
- Hyung Ki Hong, "Fabrication of electronic nose system by oxide semiconductor gas sensor array and pattern recognition technique", Proceedings of 1991 STRC Meeting on Sensor Technology, 6(1), pp.295~299 (1995)
- Spielman AI, "Halitosis:a common oral problem", N Y Dent J, 62(1), pp.36~42 (1996)
- Tonzetich J, "Chmical analysis of thiol", Disulphide and Total Sulphur Content of Human Saliva, Arch Oral Biol, 22(2), pp.125~131 (1977)
- 김선태, "악취센서 최적 제작 조건의 평가를 위한 Taguchi 실험계획법의 적용", 대한환경공학회지, 25(10), pp.17~1323 (2003), 대한환경공학회
- Han Soo Kim, "Hydrogen sulfide sensing characteristics of thick-film WO3 and WO3-PdCI2 sensors", Journal of KSEE, 25(1), pp.17~23 (2002)
- Deuk Sang Ma, "A Study on the effect of oral hygiene methods in reduction of oral malodor", The Journal of the Korean Academy of Dental Health, 14(1), pp.91~97 (1990)
- 배수민, "Full mouth disinfection이 치주질환자에서의 구취에 미치는 영향", Journal of Periodontal & Implant Science, 36(4), pp.829~837 (2006), 대한치주과학회
- 이가령, "일부 치위생과 학생들의 구취발생 및 관련요인 분석", 대한구강보건학회지, 31(2), pp.286~294 (2007), 대한구강보건학회
- 박혜숙, "구강위생관리능력이 구취 자각증상에 미치는 영향", 대한구강내과학회지, 33(2), pp.147~158 (2008), 대한안면통증∙구강내과학회
- 허혜영, "성인에서 구취실태와 요인들 간의 상관관계에 관한 연구", 대한구강보건학회지, 29(3), pp.368~385 (2005), 대한구강보건학회
- Moon Soo Park, "Epidemiologic study on oral malodor for Korean", The Journal of Korean Academy of Oral Medicine, 26(2), pp.107~114 (2001)
- 권현정, "한국인의 구취에 대한 자가 인식과 관련인자", 대한구강보건학회지, 32(2), pp.231~242 (2008), 대한구강보건학회
- 김진성, "구취환자의 임상적 특징", 대한한의학회지, 28(2), pp.13~21 (2007), 대한한의학회
- Seung Chul Shin, "An epidmiological study on malodor status in Korean people", The Journal of the Korean Academy of Dental Health, 23(4), pp.343~359 (1999)
- 손영, "스센서의최근개발동향" (2004), 한국과학기술정보연구원
