정원창 구동기의 진동체 성능 평가를 위한 내이 물리모델
A Physical Cochlear Model for Transducer Performance Evaluation of Implantable Hearing Aid with Round Window Driver
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Recently, various hearing aids are developed to overcome hearing loss. There are available hearing aids, such as air conduction hearing aid, implantable middle ear hearing aid and so on. But air conduction hearing aid is inconvenience caused by howling, and ossicle chain driving type implantable middle ear hearing aid has some week point due to problem of possible nercobiosis of coupling spot along incus long process. In recent years, in order to improve these shortcomings round window (RW) driving hearing aid has been paying attention. In this paper, the physical cochlear model is proposed for a performance evaluation of the RW driving hearing aids of a transducer. In order to verify an experiment proposed on a performance of physical cochlear model, the transducer which has ossicles characteristics is used. By measuring and comparing the frequency characteristics of transducer with ossicles and human temporal bone, performance of physical cochlear model was verified. As from the result of experiment, it is expected that an implemented cochlear model is useful for evaluating characteristics of RW transducer.
Abstract
Recently, various hearing aids are developed to overcome hearing loss. There are available hearing aids, such as air conduction hearing aid, implantable middle ear hearing aid and so on. But air conduction hearing aid is inconvenience caused by howling, and ossicle chain driving type implantable middle ear hearing aid has some week point due to problem of possible nercobiosis of coupling spot along incus long process. In recent years, in order to improve these shortcomings round window (RW) driving hearing aid has been paying attention. In this paper, the physical cochlear model is proposed for a performance evaluation of the RW driving hearing aids of a transducer. In order to verify an experiment proposed on a performance of physical cochlear model, the transducer which has ossicles characteristics is used. By measuring and comparing the frequency characteristics of transducer with ossicles and human temporal bone, performance of physical cochlear model was verified. As from the result of experiment, it is expected that an implemented cochlear model is useful for evaluating characteristics of RW transducer.
참고문헌 (14)
- H. Dillon, "Hearing Aids" (2001), Boomerang Press
- R. Goode, "The history and development of the implantable hearing aid", The Otolaryngologic Clinics of North America, 28, pp.1~6 (1995)
- B. S. Wilson, "Cochlear implants: A remakable past and a brilliant future", Hearing Research, 242(1), pp.3~21 (1995)
- R. Goode, "Current status and future of implantable electromagnetic hearing aids", The Otolaryngologic Clinics of North America, 28, pp.141~145 (1995)
- V. Colletti, "Round window stimulation with the floatimg mass transducer: A new approach for surgical failures of mixed hearing loss", Proceedings of the XVIII World Congress of the International Federation of Oto- Rhino-Laryngological Societies (2005)
- "ASTM F2504-05, Standard Practice for Describing System Output of Implantable Middle Ear Hearing Devices", ~ (2005)
- M. Schuenke, "Thieme Atlas of Anatomy : Head and Neuroanatomy" (2007), Georg Thieme Verlag
- F. Netter, "Atlas of Human Anatomy" (2011), Saunders- Elsevier
- P. Janfaza, "Harvard University Press, In Surgical Anatomy of the Head and Neck" (2011), Harvard University Press
- S. Stenfelt, "Fluid volume displacement at the oval and round windows with air and bone conduction stimulation", Journal of Acoustical Society of America, 115(2), pp.797~812 (2004)
- S. N. Merchant, "Acoustic input impedance of the stapes and cochlea in human temporal bones", Hearing Research, 97, pp.30~45 (1996)
- M. Igarashi, "Morphometric comparison of endolymphatic and perilymphatic spaces in human temporal bones", Acta Oto-laryngologica, 101, pp.161~164 (1986)
- H. G. Lim, "Design of Electromagnetic Vibrator for Round Window Driving Implantable Hearing Aids", 박사, pp.2010
- A. Arnold, "Factors improving the vibration transfer of the floating mass transducer at the round window", Otology and Neurotology, 31(1), pp.122~128 (2010)
